91 resultados para pulse compression

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

During short-term postural changes, the factors determining the amplitude of intracranial pulse pressure (ICPPA) remain constant, except for cerebrovascular resistance (CVR). Therefore, it may be possible to draw conclusions from the ICPPA onto the cerebrovascular resistance (CVR) and thus the relative change in cerebral perfusion pressure (CPP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. METHODS: A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). RESULTS: Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P < .001 vs .010). Quality of life showed no difference between the treatment groups. In both groups, pain at 90 days had decreased by half, independent of completion of healing. Physical, social, and psychic impairment improved significantly in patients with healed ulcers only. CONCLUSION: Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was not different from that of compression with bandages. Both treatments alleviated pain promptly. Quality of life was improved only in patients whose ulcers had healed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the late 1950s, reports on an unusual giant-cell granulomatous lesion affecting the jaws, lungs, stomach and intestines have been published. Histopathologically, the lesions showed the presence of structureless hyaline rings with multinucleated giant cells. The aim of this review was to summarize the literature on the etiopathogenesis of the so-called oral and extraoral pulse or hyaline ring granuloma. Literature was searched using PubMed and Medline. In addition, hand search was performed. Search words were oral and extraoral hyaline ring granuloma, giant-cell hyaline angiopathy, pulse granuloma and chronic periostitis. Numerous terms for hyaline ring granuloma have been introduced over time (1971-2008). One hundred seventy-three cases of oral hyaline ring granuloma have been retrieved from the literature. In the mandible, 72.3% occurred . Two theories for etiopathogenesis have been proposed: (1) the origin of the hyaline rings is due to a foreign material (pulse and legumes) having penetrated the oral mucosa or gastrointestinal tract and lungs (exogenous theory) and (2) the rings are due to hyaline degenerative changes in walls of blood vessels (endogenous theory). Experimental production of oral and extraoral hyaline ring granulomas is consistent with the exogenous origin. Particles or remains of leguminous cells having been implanted or aspirated into human tissues whether located to the oral cavity or throughout the entire digestive tract and respiratory system are thought to be causative. Pulse or hyaline ring granulomas are rare but are well-defined oral and extraoral lesions due to implantation of the cellulose moiety of plant foods in contrast to the starch components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose was to investigate the in vivo effects of unloading and compression on T1-Gd relaxation times in healthy articular knee cartilage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse-pressure variation (PPV) due to increased right ventricular afterload and dysfunction may misleadingly suggest volume responsiveness. We aimed to assess prediction of volume responsiveness with PPV in patients with increased pulmonary artery pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We found that pulse pressure variation (PPV) did not predict volume responsiveness in patients with increased pulmonary artery pressure. This study tests the hypothesis that PPV does not predict fluid responsiveness during an endotoxin-induced acute increase in pulmonary artery pressure and right ventricular loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Induced mild hypothermia after cardiac arrest interferes with clinical assessment of the cardiovascular status of patients. In this situation, non-invasive cardiac output measurement could be useful. Unfortunately, arterial pulse contour is altered by temperature, and the performance of devices using arterial blood pressure contour analysis to derive cardiac output may be insufficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data gathering, either for event recognition or for monitoring applications is the primary intention for sensor network deployments. In many cases, data is acquired periodically and autonomously, and simply logged onto secondary storage (e.g. flash memory) either for delayed offline analysis or for on demand burst transfer. Moreover, operational data such as connectivity information, node and network state is typically kept as well. Naturally, measurement and/or connectivity logging comes at a cost. Space for doing so is limited. Finding a good representative model for the data and providing clever coding of information, thus data compression, may be a means to use the available space to its best. In this paper, we explore the design space for data compression for wireless sensor and mesh networks by profiling common, publicly available algorithms. Several goals such as a low overhead in terms of utilized memory and compression time as well as a decent compression ratio have to be well balanced in order to find a simple, yet effective compression scheme.