5 resultados para project delay estimation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND: Estimation of respiratory deadspace is often based on the CO2 expirogram, however presence of the CO2 sensor increases equipment deadspace, which in turn influences breathing pattern and calculation of lung volume. In addition, it is necessary to correct for the delay between the sensor and flow signals. We propose a new method for estimation of effective deadspace using the molar mass (MM) signal from an ultrasonic flowmeter device, which does not require delay correction. We hypothesize that this estimation is correlated with that calculated from the CO2 signal using the Fowler method. METHODS: Breath-by-breath CO2, MM and flow measurements were made in a group of 77 term-born healthy infants. Fowler deadspace (Vd,Fowler) was calculated after correcting for the flow-dependent delay in the CO2 signal. Deadspace estimated from the MM signal (Vd,MM) was defined as the volume passing through the flowhead between start of expiration and the 10% rise point in MM. RESULTS: Correlation (r = 0.456, P < 0.0001) was found between Vd,MM and Vd,Fowler averaged over all measurements, with a mean difference of -1.4% (95% CI -4.1 to 1.3%). Vd,MM ranged from 6.6 to 11.4 ml between subjects, while Vd,Fowler ranged from 5.9 to 12.0 ml. Mean intra-measurement CV over 5-10 breaths was 7.8 +/- 5.6% for Vd,MM and 7.8 +/- 3.7% for Vd,Fowler. Mean intra-subject CV was 6.0 +/- 4.5% for Vd,MM and 8.3 +/- 5.9% for Vd,Fowler. Correcting for the CO2 signal delay resulted in a 12% difference (P = 0.022) in Vd,Fowler. Vd,MM could be obtained more frequently than Vd,Fowler in infants with CLD, with a high variability. CONCLUSIONS: Use of the MM signal provides a feasible estimate of Fowler deadspace without introducing additional equipment deadspace. The simple calculation without need for delay correction makes individual adjustment for deadspace in FRC measurements possible. This is especially important given the relative large range of deadspace seen in this homogeneous group of infants.
Resumo:
Nonallergic hypersensitivity and allergic reactions are part of the many different types of adverse drug reactions (ADRs). Databases exist for the collection of ADRs. Spontaneous reporting makes up the core data-generating system of pharmacovigilance, but there is a large under-estimation of allergy/hypersensitivity drug reactions. A specific database is therefore required for drug allergy and hypersensitivity using standard operating procedures (SOPs), as the diagnosis of drug allergy/hypersensitivity is difficult and current pharmacovigilance algorithms are insufficient. Although difficult, the diagnosis of drug allergy/hypersensitivity has been standardized by the European Network for Drug Allergy (ENDA) under the aegis of the European Academy of Allergology and Clinical Immunology and SOPs have been published. Based on ENDA and Global Allergy and Asthma European Network (GA(2)LEN, EU Framework Programme 6) SOPs, a Drug Allergy and Hypersensitivity Database (DAHD((R))) has been established under FileMaker((R)) Pro 9. It is already available online in many different languages and can be accessed using a personal login. GA(2)LEN is a European network of 27 partners (16 countries) and 59 collaborating centres (26 countries), which can coordinate and implement the DAHD across Europe. The GA(2)LEN-ENDA-DAHD platform interacting with a pharmacovigilance network appears to be of great interest for the reporting of allergy/hypersensitivity ADRs in conjunction with other pharmacovigilance instruments.
Resumo:
Data assimilation methods used for transient atmospheric state estimations in paleoclimatology such as covariance-based approaches, analogue techniques and nudging are briefly introduced. With applications differing widely, a plurality of approaches appears to be the logical way forward.
Resumo:
Palaeoclimatic information can be retrieved from the diffusion of the stable water isotope signal during firnification of snow. The diffusion length, a measure for the amount of diffusion a layer has experienced, depends on the firn temperature and the accumulation rate. We show that the estimation of the diffusion length using power spectral densities (PSDs) of the record of a single isotope species can be biased by uncertainties in spectral properties of the isotope signal prior to diffusion. By using a second water isotope and calculating the difference in diffusion lengths between the two isotopes, this problem is circumvented. We study the PSD method applied to two isotopes in detail and additionally present a new forward diffusion method for retrieving the differential diffusion length based on the Pearson correlation between the two isotope signals. The two methods are discussed and extensively tested on synthetic data which are generated in a Monte Carlo manner. We show that calibration of the PSD method with this synthetic data is necessary to be able to objectively determine the differential diffusion length. The correlation-based method proves to be a good alternative for the PSD method as it yields precision equal to or somewhat higher than the PSD method. The use of synthetic data also allows us to estimate the accuracy and precision of the two methods and to choose the best sampling strategy to obtain past temperatures with the required precision. In addition to application to synthetic data the two methods are tested on stable-isotope records from the EPICA (European Project for Ice Coring in Antarctica) ice core drilled in Dronning Maud Land, Antarctica, showing that reliable firn temperatures can be reconstructed with a typical uncertainty of 1.5 and 2 °C for the Holocene period and 2 and 2.5 °C for the last glacial period for the correlation and PSD method, respectively.
Resumo:
CODE, the Center for Orbit Determination in Europe, is a joint venture of the following four institutions: Astronomical Institute, University of Bern (AIUB), Bern, Switzerland; Federal Office of Topography swisstopo, Wabern, Switzerland; Federal Agency of Cartography and Geodesy (BKG), Frankfurt a. M., Germany; Institut für Astronomische und Physikalische Geodäsie, Technische Universität München (IAPG, TUM), Munich, Germany. It acts as a global analysis center of the International GNSS Service (IGS). The operational computations are performed at AIUB using the latest development version of the Bernese GNSS Software. In this context a multi-GNSS solution is generated considering all active GPS, GLONASS, Galileo, BeiDou (expect for GEOs), and QZSS satellites as a contribution to the IGS-MGEX project. The results are published with a delay of about two weeks.