28 resultados para progetto PCB nodo sensore wireless ultra low power monitoraggio della temperatura
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
This paper introduces an area- and power-efficient approach for compressive recording of cortical signals used in an implantable system prior to transmission. Recent research on compressive sensing has shown promising results for sub-Nyquist sampling of sparse biological signals. Still, any large-scale implementation of this technique faces critical issues caused by the increased hardware intensity. The cost of implementing compressive sensing in a multichannel system in terms of area usage can be significantly higher than a conventional data acquisition system without compression. To tackle this issue, a new multichannel compressive sensing scheme which exploits the spatial sparsity of the signals recorded from the electrodes of the sensor array is proposed. The analysis shows that using this method, the power efficiency is preserved to a great extent while the area overhead is significantly reduced resulting in an improved power-area product. The proposed circuit architecture is implemented in a UMC 0.18 [Formula: see text]m CMOS technology. Extensive performance analysis and design optimization has been done resulting in a low-noise, compact and power-efficient implementation. The results of simulations and subsequent reconstructions show the possibility of recovering fourfold compressed intracranial EEG signals with an SNR as high as 21.8 dB, while consuming 10.5 [Formula: see text]W of power within an effective area of 250 [Formula: see text]m × 250 [Formula: see text]m per channel.
Resumo:
Despite increasing life expectancy, the age of onset of natural menopause has not significantly changed in recent decades. Thus, women spend about one-third of their lives in an estrogen-deficient state if untreated. There is a need for appropriate treatment of acute symptoms and prevention of the sequelae of chronic estrogen deficiency. International guidelines call for the use of the lowest effective hormone dosage for vasomotor symptom relief, the major indication for menopausal hormone therapy (MHT). In 2011, an oral continuous combined ultra-low-dose MHT was approved in Switzerland. This publication was elaborated by eight national menopause specialists and intends to review the advantages and disadvantages of ultra-low-dose MHT after the first years of its general use in Switzerland. It concludes that, for many women, ultra-low-dose MHT may be sufficient to decrease vasomotor symptoms, but not necessarily to guarantee fracture prevention.
Resumo:
OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.
Resumo:
The Internet of Things (IoT) is attracting considerable attention from the universities, industries, citizens and governments for applications, such as healthcare, environmental monitoring and smart buildings. IoT enables network connectivity between smart devices at all times, everywhere, and about everything. In this context, Wireless Sensor Networks (WSNs) play an important role in increasing the ubiquity of networks with smart devices that are low-cost and easy to deploy. However, sensor nodes are restricted in terms of energy, processing and memory. Additionally, low-power radios are very sensitive to noise, interference and multipath distortions. In this context, this article proposes a routing protocol based on Routing by Energy and Link quality (REL) for IoT applications. To increase reliability and energy-efficiency, REL selects routes on the basis of a proposed end-to-end link quality estimator mechanism, residual energy and hop count. Furthermore, REL proposes an event-driven mechanism to provide load balancing and avoid the premature energy depletion of nodes/networks. Performance evaluations were carried out using simulation and testbed experiments to show the impact and benefits of REL in small and large-scale networks. The results show that REL increases the network lifetime and services availability, as well as the quality of service of IoT applications. It also provides an even distribution of scarce network resources and reduces the packet loss rate, compared with the performance of well-known protocols.
Resumo:
The reliability of millimeter and sub-millimeter wave radiometer measurements is dependent on the accuracy of the loads they employ as calibration targets. In the recent past on-board calibration loads have been developed for a variety of satellite remote sensing instruments. Unfortunately some of these have suffered from calibration inaccuracies which had poor thermal performance of the calibration target as the root cause. Stringent performance parameters of the calibration target such as low reflectivity, high temperature uniformity, low mass and low power consumption combined with low volumetric requirements remain a challenge for the space instrument developer. In this paper we present a novel multi-layer absorber concept for a calibration load which offers an excellent compromise between very good radiometric performance and temperature uniformity and the mass and volumetric constraints required by space-borne calibration targets.
Resumo:
Energy is of primary concern in wireless sensor networks (WSNs). Low power transmission makes the wireless links unreliable, which leads to frequent topology changes. Resulting packet retransmissions aggravate the energy consumption. Beaconless routing approaches, such as opportunistic routing (OR) choose packet forwarders after data transmissions, and are promising to support dynamic features of WSNs. This paper proposes SCAD - Sensor Context-aware Adaptive Duty-cycled beaconless OR for WSNs. SCAD is a cross-layer routing solution and it brings the concept of beaconless OR into WSNs. SCAD selects packet forwarders based on multiple types of network contexts. To achieve a balance between performance and energy efficiency, SCAD adapts duty-cycles of sensors based on real-time traffic loads and energy drain rates. We implemented SCAD in TinyOS running on top of Tmote Sky sensor motes. Real-world evaluations show that SCAD outperforms other protocols in terms of both throughput and network lifetime.
Resumo:
OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.
Resumo:
Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Resumo:
Objective: In humans and other animals, open, expansive postures (compared to contracted postures) are evolutionary developed expressions of power and have been shown to cause neuroendocrine and behavioral changes (Carney, Cuddy, & Yap, 2010). In the present study we aimed to investigate whether power postures have a bearing on the participant’s facial appearance and whether others are able to distinguish faces after “high power posing” from faces after “low power posing”. Methods: 16 models were photographed 4-5 minutes after having adopted high and low power postures. Two different high power and two different low power postures were held for 2 minutes each. Power-posing sessions were performed on two consecutive days. High and low power photographs of each model were paired and an independent sample of 100 participants were asked to pick the more dominant and the more likeable face of each pair. Results: Photographs that were taken after adopting high power postures were chosen significantly more often as being more dominant looking. There was no preference when asked to choose the more likeable photograph (chance level). A further independent sample rated each photograph for head tilt, making it unlikely that dominance ratings were caused merely by the posture of the head. Consistently, facial width-to-height ratio did not differ between faces after high and low power posing. Conclusions: Postures associated with high power affect facial appearance, leading to a more dominant looking face. This finding may have implications for everyday life, for instance when a dominant appearance is needed.
Resumo:
We recently reported that nuclear grading in prostate cancer is subject to a strong confirmation bias induced by the tumor architecture. We now wondered whether a similar bias governs nuclear grading in breast carcinoma. An unannounced test was performed at a pathology conference. Pathologists were asked to grade nuclei in a PowerPoint presentation. Circular high power fields of 27 invasive ductal carcinomas were shown, superimposed over low power background images of either tubule-rich or tubule-poor carcinomas. We found (a) that diagnostic reproducibility of nuclear grades was poor to moderate (weighed kappa values between 0.07 and 0.54, 27 cases, 44 graders), but (b) that nuclear grades were not affected by the tumor architecture. We speculate that the categorized grading in breast cancer, separating tubule formation, nuclear pleomorphism, and mitotic figure counts in a combined three tier score, prevents the bias that architecture exerts on nuclear grades in less well-controlled situations.
Resumo:
Tumor budding, a histological hallmark of epithelial-mesenchymal transition in colorectal cancer, is a parameter of tumor progression and according to the International Union Against Cancer/American Joint Committee on Cancer an 'additional' prognostic factor. The current definition of tumor budding is reserved for the invasive tumor front of colorectal cancer (so called peri-tumoral budding), but tumor buds can also be observed in small preoperative biopsy specimens. Whereas the prognostic value of peri-tumoral budding assessed in resection specimens has found wide acceptance, the value of budding in preoperative biopsies, which normally do not encompass the invasive tumor margin and hence can be called intra-tumoral budding, has not been systematically investigated yet. Therefore, the aim of this study is to assess the predictive value of intra-tumoral budding for lymph node and distant metastasis in preoperative biopsies. Preoperative biopsy samples and consecutive resection specimens from 72 patients with pathological information on TNM stage, vascular, lymphatic and perineural invasion, and tumor border configuration were used to evaluate intra-tumoral budding and peri-tumoral budding. Both parameters were scored semiquantitatively as 'high' (detectable at low power magnification × 2.5) and 'low' (occasional budding at intermediate magnification × 10, difficult to find or absent). In biopsy samples high intra-tumoral budding was observed in 12/72 patients (17%) and associated with high peri-tumoral budding in the corresponding resection specimens (P=0.008). Additionally, there was a correlation between high intra-tumoral budding and lymph node metastasis (P=0.034), distant metastasis (P=0.007) and higher tumor grade (P=0.025). Peri-tumoral budding was associated with higher N stage (P=0.004), vascular (P=0.046) and lymphatic invasion (P=0.019) as well as with an infiltrating tumor border (P<0.001), reflecting the predictive power of peri-tumoral budding for tumor progression. High intra-tumoral budding in preoperative biopsy samples of colorectal cancer patients predicts high peri-tumoral budding at the invasive margin and lymph node metastasis in the corresponding resection specimens as well as distant metastasis.
Resumo:
In the field of thrombosis and haemostasis, many preanalytical variables influence the results of coagulation assays and measures to limit potential results variations should be taken. To our knowledge, no paper describing the development and maintenance of a haemostasis biobank has been previously published. Our description of the biobank of the Swiss cohort of elderly patients with venous thromboembolism (SWITCO65+) is intended to facilitate the set-up of other biobanks in the field of thrombosis and haemostasis. SWITCO65+ is a multicentre cohort that prospectively enrolled consecutive patients aged ≥65 years with venous thromboembolism at nine Swiss hospitals from 09/2009 to 03/2012. Patients will be followed up until December 2013. The cohort includes a biobank with biological material from each participant taken at baseline and after 12 months of follow-up. Whole blood from all participants is assayed with a standard haematology panel, for which fresh samples are required. Two buffy coat vials, one PAXgene Blood RNA System tube and one EDTA-whole blood sample are also collected at baseline for RNA/DNA extraction. Blood samples are processed and vialed within 1 h of collection and transported in batches to a central laboratory where they are stored in ultra-low temperature archives. All analyses of the same type are performed in the same laboratory in batches. Using multiple core laboratories increased the speed of sample analyses and reduced storage time. After recruiting, processing and analyzing the blood of more than 1,000 patients, we determined that the adopted methods and technologies were fit-for-purpose and robust.
Resumo:
Background: Emotion research in neuroscience targets brain structures and processes involved in discrete emotion categories (e.g. anger, fear, sadness) or dimensions (e.g. valence, arousal, approach-avoidance), and usually relies on carefully controlled experimental paradigms with standardized and often simple emotion-eliciting stimuli like e.g. unpleasant pictures. Emotion research in clinical psychology and psychotherapy is often interested in very subtle differences between emotional states, e.g. differences within emotion categories (e.g. assertive, self-protecting vs. rejecting, protesting anger or specific grief vs. global sadness), and/or the biographical, social, situational, or motivational contexts of the emotional experience, which are desired to be minimized in experimental neuroscientific research. Objective: In order to facilitate the experimental and neurophysiological investigation of psychotherapeutically relevant emotional experiences, the present study aims at developing a priming procedure to induce specific, therapeutically and biographically relevant emotional states under controlled experimental conditions. Methodology: N = 50 participants who reported negative feelings towards another close person were randomly assigned to 2 different conditions. They fulfilled 2 different sentence completion tasks that were supposed to prime either ‘therapeutically productive’ or ‘therapeutically unproductive’ emotional states and completed an expressive writing task and several self-report measures of specific emotion-related constructs. The sentence completion task consisted in max. 22 sentence stems drawn from psychotherapy patients’ statements that have been shown to be typical for productive or unproductive therapy sessions. The subjects of the present study completed these sentence stems with regard to their own negative feelings towards the close person. Results: There were a substantial inter-individual variability concerning the number of completed sentences, and significant correlations between number of completed sentences and problem activation in both conditions. No differences were observed in general mood or problem activation between both groups after priming. Descriptively, there were differences between groups concerning emotion regulation aspects. Significant differences between groups in resolution of negative feelings towards the other person were found. Discussion: The results point in the expected direction, however the small sample sizes (after exclusion of several subjects) and low power hinder the detection of convincing significant effects. More data is needed in order to evaluate the efficacy of this emotional priming procedure.