6 resultados para product safety

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND The variant Creutzfeldt-Jakob disease incidence peaked a decade ago and has since declined. Based on epidemiologic evidence, the causative agent, pathogenic prion, has not constituted a tangible contamination threat to large-scale manufacturing of human plasma-derived proteins. Nonetheless, manufacturers have studied the prion removal capabilities of various manufacturing steps to better understand product safety. Collectively analyzing the results could reveal experimental reproducibility and detect trends and mechanisms driving prion removal. STUDY DESIGN AND METHODS Plasma Protein Therapeutics Association member companies collected more than 200 prion removal studies on plasma protein manufacturing steps, including precipitation, adsorption, chromatography, and filtration, as well as combined steps. The studies used a range of model spiking agents and bench-scale process replicas. The results were grouped based on key manufacturing variables to identify factors impacting removal. The log reduction values of a group are presented for comparison. RESULTS Overall prion removal capacities evaluated by independent groups were in good agreement. The removal capacity evaluated using biochemical assays was consistent with prion infectivity removal measured by animal bioassays. Similar reduction values were observed for a given step using various spiking agents, except highly purified prion protein in some circumstances. Comparison between combined and single-step studies revealed complementary or overlapping removal mechanisms. Steps with high removal capacities represent the conditions where the physiochemical differences between prions and therapeutic proteins are most significant. CONCLUSION The results support the intrinsic ability of certain plasma protein manufacturing steps to remove prions in case of an unlikely contamination, providing a safeguard to products.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: The risk of transfusion-transmitted HBV remains significant in Switzerland, where routine screening for hepatitis B virus (HBV) in blood donations relies solely on serological hepatitis B surface antigen (HBsAg) testing. This study was designed to determine the prevalence of anti-hepatitis B core (anti-HBc) and HBV nucleic acid testing (NAT) positive donations in two different Swiss donor populations, to help in deciding whether supplemental testing may bring additional safety to blood products. METHODS: In a first population of donors, 18143 consecutive donations were screened initially for HBsAg, anti-HBc (with one EIA assay) and with HBV NAT in minipools of 24 donations. The screening repeatedly reactive anti-HBc donations were then "confirmed" with two supplemental anti-HBc assays, an anti-hepatitis B surface assay (anti-HBs) and with single donation HBV NAT. In a second population of donors, 4186 consecutive donations were screened initially with two different anti-HBc assays in addition to the mandatory HBsAg screening test. The screening repeatedly reactive donations with at least one anti-HBc assay were tested for anti-HBs. RESULTS: In the first subset of 18143 donations, 17593 (97.0%) were negative for HBsAg, anti-HBc and HBV NAT in minipools. 549 (3.0%) were HBsAg and HBV NAT negative, but repeatedly reactive for anti-HBc. Of these 549 donations, 287 could not be "confirmed" with two additional anti-HBc assays and were negative with an anti-HBs assay, as well as with single donation HBV NAT. Only 211 (1.2% of the total screened donations) were "confirmed" positive with at least one of two supplemental anti-HBc assays. One repeatedly reactive HBsAg donation, from a first-time donor, was confirmed positive for HBsAg and anti-HBc, as well as with single donation HBV NAT. In the second subset of 4186 donations, 4014 (95.9%) were screened negative for HBsAg and for anti-HBc, tested with two independent anti-HBc assays. 172 donations (4.1%) were HBsAg negative but repeatedly reactive with at least one of the two anti-HBc assays. Of these 172 samples, 86 were reactive with the first anti-HBc assay only, 13 were reactive with the second anti-HBc assay only and 73 (1.7% of the total screened donations) were "confirmed" positive with both anti-HBc assays. CONCLUSION: The prevalence of anti-HBc "confirmed" positive donations in the two Swiss blood donor populations studied was low (<2%) and we found only one HBV NAT positive (HBsAg positive) donation among more than 18000. Concerning blood product safety, an increase in the deferral rate of less than 2% of anti-HBc positive, potentially infectious donors, would in our opinion make routine anti-HBc testing of blood donations cost-effective. There is however still a need for more specific assays to avoid an unacceptably high deferral rate of "false" positive donors. In contrast, the introduction of HBV NAT in minipools gives minimal benefit due to the inadequate sensitivity of the assay. It remains to evaluate more extensively the value of individual donation NAT, alone or in addition to anti-HBc, as supplemental testing in the context of several Swiss blood donor populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The Health Technology Assessment report on effectiveness, cost-effectiveness and appropriateness of homeopathy was compiled on behalf of the Swiss Federal Office for Public Health (BAG) within the framework of the 'Program of Evaluation of Complementary Medicine (PEK)'. Materials and Methods: Databases accessible by Internet were systematically searched, complemented by manual search and contacts with experts, and evaluated according to internal and external validity criteria. Results: Many high-quality investigations of pre-clinical basic research proved homeopathic high-potencies inducing regulative and specific changes in cells or living organisms. 20 of 22 systematic reviews detected at least a trend in favor of homeopathy. In our estimation 5 studies yielded results indicating clear evidence for homeopathic therapy. The evaluation of 29 studies in the domain 'Upper Respiratory Tract Infections/Allergic Reactions' showed a positive overall result in favor of homeopathy. 6 out of 7 controlled studies were at least equivalent to conventional medical interventions. 8 out of 16 placebocontrolled studies were significant in favor of homeopathy. Swiss regulations grant a high degree of safety due to product and training requirements for homeopathic physicians. Applied properly, classical homeopathy has few side-effects and the use of high-potencies is free of toxic effects. A general health-economic statement about homeopathy cannot be made from the available data. Conclusion: Taking internal and external validity criteria into account, effectiveness of homeopathy can be supported by clinical evidence and professional and adequate application be regarded as safe. Reliable statements of cost-effectiveness are not available at the moment. External and model validity will have to be taken more strongly into consideration in future studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To prove non-inferiority of the first non-hormonal vaginal cream in Germany, Vagisan(®) Moisturising Cream (CREAM), compared to a non-hormonal vaginal gel (GEL) for vulvovaginal atrophy (VVA) symptom relief. METHOD This was a 12-week multicenter, open-label, prospective, randomized, two-period, cross-over phase-III trial. The primary endpoint was the cumulative VVA subjective symptom score of the respective treatment period. Secondary endpoints were assessment of single VVA subjective and objective symptoms, VVA objective symptom score, vaginal pH, safety parameters, overall assessment of efficacy, tolerability and evaluation of product properties. In total, 117 women were randomly allocated to either one of the two treatments, each administered for 4 weeks; 92 women were included in the per-protocol analysis (primary analysis). The main outcome measure was cumulative VVA subjective symptom score. RESULTS Regarding VVA symptom relief, results confirmed non-inferiority of CREAM compared to GEL and even indicated superiority of CREAM. Frequency and intensity of subjective symptoms and objective findings were clearly reduced, with CREAM showing better results compared to GEL. Mean VVA objective symptom score significantly decreased; improvement was significantly greater with CREAM. Vaginal pH decreased only following CREAM treatment. Tolerability was superior for CREAM: burning and itching, mostly rated as mild, occurred markedly less often with CREAM than with GEL. Overall satisfaction with treatment efficacy, tolerability and most product properties were rated significantly superior for CREAM. CONCLUSIONS Subjective and objective VVA symptoms were reliably and safely reduced by both non-hormonal topical products. However, efficacy and tolerability of CREAM were shown to be superior to GEL.