80 resultados para precision limit
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We introduce a new fiber-optical approach for reflection based refractive index mapping. Our approach leads to improved stability and reliability over existing free-space confocal instruments and significantly cuts alignment efforts and reduces the number of components needed. Other than properly cleaved fiber end-faces, this setup requires no additional sample preparation. The instrument is calibrated by means of a set of samples with known refractive indices. The index steps of commercially available fibers are measured accurately down to < 10⁻³. The precision limit of the instrument is currently of the order of 10⁻⁴.
Resumo:
Perinatal care of pregnant women at high risk for preterm delivery and of preterm infants born at the limit of viability (22-26 completed weeks of gestation) requires a multidisciplinary approach by an experienced perinatal team. Limited precision in the determination of both gestational age and foetal weight, as well as biological variability may significantly affect the course of action chosen in individual cases. The decisions that must be taken with the pregnant women and on behalf of the preterm infant in this context are complex and have far-reaching consequences. When counselling pregnant women and their partners, neonatologists and obstetricians should provide them with comprehensive information in a sensitive and supportive way to build a basis of trust. The decisions are developed in a continuing dialogue between all parties involved (physicians, midwives, nursing staff and parents) with the principal aim to find solutions that are in the infant's and pregnant woman's best interest. Knowledge of current gestational age-specific mortality and morbidity rates and how they are modified by prenatally known prognostic factors (estimated foetal weight, sex, exposure or nonexposure to antenatal corticosteroids, single or multiple births) as well as the application of accepted ethical principles form the basis for responsible decision-making. Communication between all parties involved plays a central role. The members of the interdisciplinary working group suggest that the care of preterm infants with a gestational age between 22 0/7 and 23 6/7 weeks should generally be limited to palliative care. Obstetric interventions for foetal indications such as Caesarean section delivery are usually not indicated. In selected cases, for example, after 23 weeks of pregnancy have been completed and several of the above mentioned prenatally known prognostic factors are favourable or well informed parents insist on the initiation of life-sustaining therapies, active obstetric interventions for foetal indications and provisional intensive care of the neonate may be reasonable. In preterm infants with a gestational age between 24 0/7 and 24 6/7 weeks, it can be difficult to determine whether the burden of obstetric interventions and neonatal intensive care is justified given the limited chances of success of such a therapy. In such cases, the individual constellation of prenatally known factors which impact on prognosis can be helpful in the decision making process with the parents. In preterm infants with a gestational age between 25 0/7 and 25 6/7 weeks, foetal surveillance, obstetric interventions for foetal indications and neonatal intensive care measures are generally indicated. However, if several prenatally known prognostic factors are unfavourable and the parents agree, primary non-intervention and neonatal palliative care can be considered. All pregnant women with threatening preterm delivery or premature rupture of membranes at the limit of viability must be transferred to a perinatal centre with a level III neonatal intensive care unit no later than 23 0/7 weeks of gestation, unless emergency delivery is indicated. An experienced neonatology team should be involved in all deliveries that take place after 23 0/7 weeks of gestation to help to decide together with the parents if the initiation of intensive care measures appears to be appropriate or if preference should be given to palliative care (i.e., primary non-intervention). In doubtful situations, it can be reasonable to initiate intensive care and to admit the preterm infant to a neonatal intensive care unit (i.e., provisional intensive care). The infant's clinical evolution and additional discussions with the parents will help to clarify whether the life-sustaining therapies should be continued or withdrawn. Life support is continued as long as there is reasonable hope for survival and the infant's burden of intensive care is acceptable. If, on the other hand, the health car...
Resumo:
The objective of this pilot investigation was to evaluate the utility and precision of already existing limited cone-beam computed tomography (CBCT) scans in measuring the endodontic working length, and to compare it with standard clinical procedures.
Resumo:
A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.
Resumo:
In order to provide high precision stable carbon isotope ratios (δ13CO2 or δ13C of CO2) from small bubbly, partially and fully clathrated ice core samples we developed a new method based on sublimation coupled to gas chromatography-isotope ratio mass spectrometry (GC-IRMS). In a first step the trapped air is quantitatively released from ~30 g of ice and CO2 together with N2O are separated from the bulk air components and stored in a miniature glass tube. In an off-line step, the extracted sample is introduced into a helium carrier flow using a minimised tube cracker device. Prior to measurement, N2O and organic sample contaminants are gas chromatographically separated from CO2. Pulses of a CO2/N2O mixture are admitted to the tube cracker and follow the path of the sample through the system. This allows an identical treatment and comparison of sample and standard peaks. The ability of the method to reproduce δ13C from bubble and clathrate ice is verified on different ice cores. We achieve reproducibilities for bubble ice between 0.05 ‰ and 0.07 ‰ and for clathrate ice between 0.05 ‰ and 0.09 ‰ (dependent on the ice core used). A comparison of our data with measurements on bubble ice from the same ice core but using a mechanical extraction device shows no significant systematic offset. In addition to δ13C, the CO2 and N2O mixing ratios can be volumetrically derived with a precision of 2 ppmv and 8 ppbv, respectively.