34 resultados para portable instruments
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Three-dimensional (3D) models of teeth and soft and hard tissues are tessellated surfaces used for diagnosis, treatment planning, appliance fabrication, outcome evaluation, and research. In scientific publications or communications with colleagues, these 3D data are often reduced to 2-dimensional pictures or need special software for visualization. The portable document format (PDF) offers a simple way to interactively display 3D surface data without additional software other than a recent version of Adobe Reader (Adobe, San Jose, Calif). The purposes of this article were to give an example of how 3D data and their analyses can be interactively displayed in 3 dimensions in electronic publications, and to show how they can be exported from any software for diagnostic reports and communications among colleagues.
Resumo:
Image overlay projection is a form of augmented reality that allows surgeons to view underlying anatomical structures directly on the patient surface. It improves intuitiveness of computer-aided surgery by removing the need for sight diversion between the patient and a display screen and has been reported to assist in 3-D understanding of anatomical structures and the identification of target and critical structures. Challenges in the development of image overlay technologies for surgery remain in the projection setup. Calibration, patient registration, view direction, and projection obstruction remain unsolved limitations to image overlay techniques. In this paper, we propose a novel, portable, and handheld-navigated image overlay device based on miniature laser projection technology that allows images of 3-D patient-specific models to be projected directly onto the organ surface intraoperatively without the need for intrusive hardware around the surgical site. The device can be integrated into a navigation system, thereby exploiting existing patient registration and model generation solutions. The position of the device is tracked by the navigation system’s position sensor and used to project geometrically correct images from any position within the workspace of the navigation system. The projector was calibrated using modified camera calibration techniques and images for projection are rendered using a virtual camera defined by the projectors extrinsic parameters. Verification of the device’s projection accuracy concluded a mean projection error of 1.3 mm. Visibility testing of the projection performed on pig liver tissue found the device suitable for the display of anatomical structures on the organ surface. The feasibility of use within the surgical workflow was assessed during open liver surgery. We show that the device could be quickly and unobtrusively deployed within the sterile environment.
Resumo:
The histological status of the sentinel lymph node (SLN) is one of the most relevant prognostic factors for the overall survival of patients with cutaneous malignancies, independent of tumour depth of the primary tumour.
Resumo:
Ventricular assist devices (VADs) and total artificial hearts have been in development for the last 50 years. Since their inception, simulators of the circulation with different degrees of complexity have been produced to test these devices in vitro. Currently, a new path has been taken with the extensive efforts to develop paediatric VADs, which require totally different design constraints. This paper presents the manufacturing details of an economical simulator of the systemic paediatric circulation. This simulator allows the insertion of a paediatric VAD, includes a pumping ventricle, and is adjustable within the paediatric range. Rather than focusing on complexity and physiological simulation, this simulator is designed to be simple and practical for rapid device testing. The simulator was instrumented with medical sensors and data were acquired under different conditions with and without the new PediaFlowTM paediatric VAD. The VAD was run at different impeller speeds while simulator settings such as vascular resistance and stroke volume were varied. The hydraulic performance of the VAD under pulsatile conditions could be characterized and the magnetic suspension could be tested via manipulations such as cannula clamping. This compact mock loop has proven to be valuable throughout the PediaFlow development process and has the advantage that it is uncomplicated and can be manufactured cheaply. It can be produced by several research groups and the results of different VADs can then be compared easily.
Resumo:
Presenting visual feedback for image-guided surgery on a monitor requires the surgeon to perform time-consuming comparisons and diversion of sight and attention away from the patient. Deficiencies in previously developed augmented reality systems for image-guided surgery have, however, prevented the general acceptance of any one technique as a viable alternative to monitor displays. This work presents an evaluation of the feasibility and versatility of a novel augmented reality approach for the visualisation of surgical planning and navigation data. The approach, which utilises a portable image overlay device, was evaluated during integration into existing surgical navigation systems and during application within simulated navigated surgery scenarios.
Resumo:
A literature review of the most widely used condition specific, self administered assessment questionnaires for low back pain had been undertaken. General and historic aspects, reliability, responsiveness and minimum clinically important difference, external validity, floor and ceiling effects, and available languages were analysed. These criteria, however, are only part of the consideration. Of similar importance are the content, wording of questions and answers in each of the six questionnaires and an analysis of the different score results. The issue of score bias is discussed and suggestions are given in order to increase the construct validity in the practical use of the individual questionnaires.
Resumo:
BACKGROUND: Due to the increasing importance of quality of life assessments in chronic obstructive pulmonary disease (COPD) patients, and the increased use of the International Classification of Functioning, Disability and Health (ICF) for comparative purposes it is essential to understand the relationship between health-related quality of life (HRQL) instruments and the ICF. OBJECTIVE: The objective of this study was to compare the content of recommended COPD-specific HRQL instruments using the ICF as reference. COPD-specific instruments mentioned in widely accepted guidelines were linked to the ICF using standardized linking rules. The degree of agreement between various health professionals was assessed by calculating the kappa statistic. RESULTS: Eleven instruments were included. They varied strongly in the number of concepts contained and the number of ICF categories used to map these concepts. A total of 548 concepts were identified and linked to 60 different ICF categories. Only the single category 'dyspnea' was covered by all instruments, whilst 21 categories were unique to specific instruments. The relationships of the measures with the ICF were identified. CONCLUSIONS: This study may aid researchers and clinicians to choose the most appropriate instrument for a specific purpose as well as help compare studies that have used different instruments for HRQL assessment.
Resumo:
To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements.
Resumo:
BACKGROUND AND PURPOSE: Due to the increasing importance of quality of life assessments in obstructive sleep apnea (OSA) patients and due to an increased use of the International Classification of Functioning, Disability and Health (ICF), for comparative purposes it is essential to understand the relationship between health-related quality of life (HRQOL) instruments and the ICF. The purpose of this study was to compare the content covered by OSA-specific instruments using the ICF. PATIENTS AND METHODS: OSA-specific instruments were identified, including the Calgary Sleep Apnea Quality of Life Index, the Functional Outcomes of Sleep Questionnaire, the Obstructive Sleep Apnea Patient-Oriented Severity Index, and the Quebec Sleep Questionnaire, and linked to the ICF by six health professionals according to standardized guidelines. The degree of agreement between health professionals was calculated by means of the kappa statistic. RESULTS: A total of 308 concepts were identified and linked to 78 different ICF categories; 35 categories of the component body function, one category of the component body structure, 38 categories of the component activities and participation, and four categories of the component environmental factors. Only contents within the chapters mental functions, mobility and social life were addressed by all instruments. Forty-seven categories were covered by only one instrument. CONCLUSION: The ICF proved highly useful for the comparison of HRQOL instruments. This analysis may help researchers and clinicians to choose the most appropriate HRQOL instrument for a specific purpose as well as help to compare study outcomes of studies using different instruments for HRQOL assessment.