10 resultados para planning control

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONCLUSION: Our self-developed planning and navigation system has proven its capacity for accurate surgery on the anterior and lateral skull base. With the incorporation of augmented reality, image-guided surgery will evolve into 'information-guided surgery'. OBJECTIVE: Microscopic or endoscopic skull base surgery is technically demanding and its outcome has a great impact on a patient's quality of life. The goal of the project was aimed at developing and evaluating enabling navigation surgery tools for simulation, planning, training, education, and performance. This clinically applied technological research was complemented by a series of patients (n=406) who were treated by anterior and lateral skull base procedures between 1997 and 2006. MATERIALS AND METHODS: Optical tracking technology was used for positional sensing of instruments. A newly designed dynamic reference base with specific registration techniques using fine needle pointer or ultrasound enables the surgeon to work with a target error of < 1 mm. An automatic registration assessment method, which provides the user with a color-coded fused representation of CT and MR images, indicates to the surgeon the location and extent of registration (in)accuracy. Integration of a small tracker camera mounted directly on the microscope permits an advantageous ergonomic way of working in the operating room. Additionally, guidance information (augmented reality) from multimodal datasets (CT, MRI, angiography) can be overlaid directly onto the surgical microscope view. The virtual simulator as a training tool in endonasal and otological skull base surgery provides an understanding of the anatomy as well as preoperative practice using real patient data. RESULTS: Using our navigation system, no major complications occurred in spite of the fact that the series included difficult skull base procedures. An improved quality in the surgical outcome was identified compared with our control group without navigation and compared with the literature. The surgical time consumption was reduced and more minimally invasive approaches were possible. According to the participants' questionnaires, the educational effect of the virtual simulator in our residency program received a high ranking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new system for computer-aided corrective surgery of the jaws has been developed and introduced clinically. It combines three-dimensional (3-D) surgical planning with conventional dental occlusion planning. The developed software allows simulating the surgical correction on virtual 3-D models of the facial skeleton generated from computed tomography (CT) scans. Surgery planning and simulation include dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and segment repositioning. By coupling the software with a tracking system and with the help of a special registration procedure, we are able to acquire dental occlusion plans from plaster model mounts. Upon completion of the surgical plan, the setup is used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with the help of a display showing jaw positions and 3-D positioning guides updated in real time during the surgical procedure. The proposed approach offers the advantages of 3-D visualization and tracking technology without sacrificing long-proven cast-based techniques for dental occlusion evaluation. The system has been applied on one patient. Throughout this procedure, we have experienced improved assessment of pathology, increased precision, and augmented control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When a hand-held object is moved, grip and load force are accurately coordinated for establishing grasp stability. In the present work, the question was raised whether patients with Gilles de la Tourette syndrome (TS), who show tic-like movements, are impaired in grip-load force control when executing a manipulative task. To this end, we assessed force regulation during action patterns that required rhythmical unimanual or bimanual (iso-directional/anti-directional) movements. Results showed that the profile of grip-load force ratio was characterized by maxima and minima that were realized at upward and downward hand positions, respectively. TS patients showed increased force ratios during unimanual and bimanual movements, compared with control subjects, indicative of an inaccurate specification of the precision grip. Functional imaging data complemented the behavioural results and revealed that secondary motor areas showed no (or greatly reduced) activation in TS patients when executing the movement tasks as compared with baseline conditions. This indicates that the metabolic level in the secondary motor areas was equal during rest and task performance. At the neuronal level, this observation suggests that these cortical areas were continuously involved in movement preparation. Based on these data, we conclude that the ongoing activation of secondary motor areas may be explained by the TS patients' involuntary urges to move. Accordingly, interference will prevent an accurate planning of voluntary behaviour. Together, these findings reveal modulations in movement organization in patients with TS and exemplify degrading consequences for manual function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Few studies have addressed the interaction between instruction content and saccadic eye movement control. To assess the impact of instructions on top-down control, we instructed 20 healthy volunteers to deliberately delay saccade triggering, to make inaccurate saccades or to redirect saccades--i.e. to glimpse towards and then immediately opposite to the target. Regular pro- and antisaccade tasks were used for comparison. Bottom-up visual input remained unchanged and was a gap paradigm for all instructions. In the inaccuracy and delay tasks, both latencies and accuracies were detrimentally impaired by either type of instruction and the variability of latency and accuracy was increased. The intersaccadic interval (ISI) required to correct erroneous antisaccades was shorter than the ISI for instructed direction changes in the redirection task. The word-by-word instruction content interferes with top-down saccade control. Top-down control is a time consuming process, which may override bottom-up processing only during a limited time period. It is questionable whether parallel processing is possible in top-down control, since the long ISI for instructed direction changes suggests sequential planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single planning interventions have been found to promote short-term dietary change. Repeated planning interventions may foster long-term effects on behavior change. It remains unknown whether there is a critical number of boosters to establish long-term maintenance of behavioral changes. This study aimed at investigating what social-cognitive variables mediate the effects of the interventions on dietary behavior change. Overall, 373 participants (n = 270 women, 72.4%; age M = 52.42, SD = 12.79) were randomly allocated to one of five groups: a control group, a single planning group, and three groups with 3, 6, or 9 weeks' repeated planning interventions. Follow-ups took place 4, 6, and 12 months after baseline. Change in fat consumption was not promoted by any of the interventions. In terms of social-cognitive variables, intentions, self-efficacy and coping planning displayed a time × group interaction, with the 9 weeks' planning group showing the most beneficial effects. Effect sizes, however, were very small. None of the tested planning interventions successfully promoted change in fat consumption across the 12 month period. This, however, could not be explained by problems with adherence to the intervention protocol. Potential explanations for this unexpected result are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study evaluated personal resource-oriented interventions supporting the career development of young academics, working at German universities within the STEM fields. The study sought to foster subjective career success by improving networking behavior, career planning, and career optimism. The study involved a quasi-experimental pre-post intervention with two intervention and two control groups (N = 81 research associates). Participants of the first intervention group received networking training; participants of the second intervention group received the same networking training plus individual career coaching. Participants of both intervention groups were female. Participants of the control groups (i.e., male vs. female group) did not participate in any intervention. As expected, path analyses, based on mean differences frompre-test to post-test, revealed an increase in career planning and career optimism within the networking plus career coaching intervention group, that was indirectly positively related to changes in subjective career success. Contrary to our expectations, the networking group training alone and in combination with the career coaching showed no effectiveness in fostering networking behavior. Results are discussed in the context of career counseling and intervention effectiveness studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The pararectus approach has been validated for managing acetabular fractures. We hypothesised it might be an alternative approach for performing periacetabular osteotomy (PAO). METHODS Using four cadaver specimens, we randomly performed PAO through either the pararectus or a modified Smith-Petersen (SP) approach. We assessed technical feasibility and safety. Furthermore, we controlled fragment mobility using a surgical navigation system and compared mobility between approaches. The navigation system's accuracy was tested by cross-examination with validated preoperative planning software. RESULTS The pararectus approach is technically feasible, allowing for adequate exposure, safe osteotomies and excellent control of structures at risk. Fragment mobility is equal to that achieved through the SP approach. Validation of these measurements yielded a mean difference of less <1 mm without statistical significance. CONCLUSION Experimental data suggests the pararectus approach might be an alternative approach for performing PAO. Clinical validation is necessary to confirm these promising preliminary results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.