26 resultados para performance monitoring

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Contemporary models of self-regulated learning emphasize the role of distal motivational factors for student's achievement, on the one side, and the proximal role of metacognitive monitoring and control for learning and test outcomes, on the other side. In the present study, two larger samples of elementary school children (9- and 11-year-olds) were included and their mastery-oriented motivation, metacognitive monitoring and control skills were integrated into structural equation models testing and comparing the relative impact of these different constituents for self-regulated learning. For one, results indicate that the factorial structure of monitoring, control and mastery motivation was invariant across the two age groups. Of specific interest was the finding that there were age-dependent structural links between monitoring, control, and test performance (closer links in the older compared to the younger children), with high confidence yielding a direct and positive effect on test performance and a direct and negative effect on adequate control behavior in the achievement test. Mastery-oriented motivation was not found to be substantially associated with monitoring (confidence), control (detection and correction of errors), or test performance underlining the importance of proximal, metacognitive factors for test performance in elementary school children.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study focuses on relations between 7- and 9-year-old children’s and adults’ metacognitive monitoring and control processes. In addition to explicit confidence judgments (CJ), data for participants’ control behavior during learning and recall as well as implicit CJs were collected with an eye-tracking device (Tobii 1750). Results revealed developmental progression in both accuracy of implicit and explicit monitoring across age groups. In addition, efficiency of learning and recall strategies increases with age, as older participants allocate more fixation time to critical information and less time to peripheral or potentially interfering information. Correlational analyses, recall performance, metacognitive monitoring, and controlling indicate significant interrelations between all of these measures, with varying patterns of correlations within age groups. Results are discussed in regard to the intricate relationship between monitoring and recall and their relation to performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Self-monitoring of blood glucose (SMBG) in type 2 diabetes has increasingly been shown to display beneficial effects on glycemic control. SMBG is not only associated with a reduction of hemoglobin A1c but has also been demonstrated to increase patients' awareness of the disease. SMBG has also the potential to visualize and predict hypoglycemic episodes. International guidelines by the International Diabetes Federation, the European Society of Cardiology, and the European Association for the Study of Diabetes and also the International Society for Pediatric and Adolescent Diabetes emphasize that SMBG is an integral part of self-management. More recently, two European consensus documents have been published to give recommendations for frequency and timing of SMBG also for various clinical scenarios. Recently, a European expert panel was held to further facilitate and enhance standardized approaches to SMBG. The aim was to present simple, clinically meaningful, and standardized SMBG strategies for type 2 diabetes. The panel recommended a less intensive and an intensive scheme for SMBG across the type 2 diabetes continuum. The length and frequency of SMBG performance depend on the clinical circumstances and the quality of glycemic control. The expert panel also recommended further evaluation of various schemes for SMBG in type 2 diabetes in clinical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiparameter cerebral monitoring has been widely applied in traumatic brain injury to study posttraumatic pathophysiology and to manage head-injured patients (e.g., combining O(2) and pH sensors with cerebral microdialysis). Because a comprehensive approach towards understanding injury processes will also require functional measures, we have added electrophysiology to these monitoring modalities by attaching a recording electrode to the microdialysis probe. These dual-function (microdialysis/electrophysiology) probes were placed in rats following experimental fluid percussion brain injuries, and in a series of severely head-injured human patients. Electrical activity (cell firing, EEG) was monitored concurrently with microdialysis sampling of extracellular glutamate, glucose and lactate. Electrophysiological parameters (firing rate, serial correlation, field potential occurrences) were analyzed offline and compared to dialysate concentrations. In rats, these probes demonstrated an injury-induced suppression of neuronal firing (from a control level of 2.87 to 0.41 spikes/sec postinjury), which was associated with increases in extracellular glutamate and lactate, and decreases in glucose levels. When placed in human patients, the probes detected sparse and slowly firing cells (mean = 0.21 spike/sec), with most units (70%) exhibiting a lack of serial correlation in the spike train. In some patients, spontaneous field potentials were observed, suggesting synchronously firing neuronal populations. In both the experimental and clinical application, the addition of the recording electrode did not appreciably affect the performance of the microdialysis probe. The results suggest that this technique provides a functional monitoring capability which cannot be obtained when electrophysiology is measured with surface or epidural EEG alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, screening tests for monitoring the prevalence of transmissible spongiform encephalopathies specifically in sheep and goats became available. Although most countries require comprehensive test validation prior to approval, little is known about their performance under normal operating conditions. Switzerland was one of the first countries to implement 2 of these tests, an enzyme-linked immunosorbent assay (ELISA) and a Western blot, in a 1-year active surveillance program. Slaughtered animals (n = 32,777) were analyzed in either of the 2 tests with immunohistochemistry for confirmation of initial reactive results, and fallen stock samples (n = 3,193) were subjected to both screening tests and immunohistochemistry in parallel. Initial reactive and false-positive rates were recorded over time. Both tests revealed an excellent diagnostic specificity (>99.5%). However, initial reactive rates were elevated at the beginning of the program but dropped to levels below 1% with routine and enhanced staff training. Only those in the ELISA increased again in the second half of the program and correlated with the degree of tissue autolysis in the fallen stock samples. It is noteworthy that the Western blot missed 1 of the 3 atypical scrapie cases in the fallen stock, indicating potential differences in the diagnostic sensitivities between the 2 screening tests. However, an estimation of the diagnostic sensitivity for both tests on field samples remained difficult due to the low disease prevalence. Taken together, these results highlight the importance of staff training, sample quality, and interlaboratory comparison trials when such screening tests are implemented in the field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of a robust assay based on MEKC for cefepime in human serum and plasma with internal quality assurance is reported. Sample preparation comprises protein precipitation in the presence of SDS at pH 4.5. This is a gentle approach for which decomposition of cefepime during sample handling is negligible. After hydrodynamic sample injection of the supernatant, analysis occurs in a phosphate/borate buffer at pH 9.1 with 75 mM SDS using normal polarity and analyte detection at 257 nm. The MEKC run time interval and throughput are about 5 min and seven samples per hour, respectively. The calibration range for cefepime is 1-60 μg/mL, with 1 μg/mL being the LOQ. The performance of the assay with multilevel internal calibration was assessed with calibration and control samples. The assay is shown to be simple, inexpensive, reproducible, and robust. It was applied to determine cefepime levels in the sera of critically ill patients and to assess the instability of cefepime in patient and control samples. Our data revealed that serum containing cefepime can be stored at -20°C for a short time, whereas for long-term storage, samples have to be kept at -70°C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New directly acting antivirals (DAAs) that inhibit hepatitis C virus (HCV) replication are increasingly used for the treatment of chronic hepatitis C. A marked pharmacokinetic variability and a high potential for drug-drug interactions between DAAs and numerous drug classes have been identified. In addition, ribavirin (RBV), commonly associated with hemolytic anemia, often requires dose adjustment, advocating for therapeutic drug monitoring (TDM) in patients under combined antiviral therapy. However, an assay for the simultaneous analysis of RBV and DAAs constitutes an analytical challenge because of the large differences in polarity among these drugs, ranging from hydrophilic (RBV) to highly lipophilic (telaprevir [TVR]). Moreover, TVR is characterized by erratic behavior on standard octadecyl-based reversed-phase column chromatography and must be separated from VRT-127394, its inactive C-21 epimer metabolite. We have developed a convenient assay employing simple plasma protein precipitation, followed by high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of levels of RBV, boceprevir, and TVR, as well as its metabolite VRT-127394, in plasma. This new, simple, rapid, and robust HPLC-MS/MS assay offers an efficient method of real-time TDM aimed at maximizing efficacy while minimizing the toxicity of antiviral therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Ischemia monitoring cannot always be performed by 12-lead ECG. Hence, the individual performance of the ECG leads is crucial. No experimental data on the ECG's specificity for transient ischemia exist. Methods: In 45 patients a 19-lead ECG was registered during a 1-minute balloon occlusion of a coronary artery (left anterior descending artery [LAD], right coronary artery [RCA] or left circumflex artery [LCX]). ST-segment shifts and sensitivity/specificity of the leads were measured. Results: During LAD occlusion, V3 showed maximal ST-segment elevation (0.26 mV [IQR 0.16–0.33 mV], p = 0.001) and sensitivity/specificity (88% and 80%). During RCA occlusion, III showed maximal ST-elevation (0.2 mV [IQR 0.09–0.26 mV], p = 0.004), aVF had the best sensitivity/specificity (85% and 68%). During LCX occlusion, V6 showed maximal ST-segment elevation (0.04 mV [IQR 0.02–0.14 mV], p = 0.005), and sensitivity/specificity was (31%/92%) but could be improved (63%/72%) using an optimized cut-off for ischemia. Conclusion: V3, aVF and V6 show the best performance to detect transient ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Responding to bivalent stimuli (i.e., stimuli with features relevant for different tasks) slows subsequent performance. In prospective memory research, prospective memory targets can be considered as bivalent stimuli because they typically involve features relevant for both the prospective memory task and the ongoing task. The purpose of this study was to investigate how responding to a prospective memory target slows subsequent performance. In two experiments, we embedded the prospective memory task in a task-switching paradigm and we manipulated the degree of task-set overlap between the prospective memory task and the ongoing task. The results showed consistent after-effects of responding to prospective memory targets. The specific trajectory of the slowing depended on the amount of task-set overlap. These results demonstrate that responding to prospective memory targets results in after-effects, a so far neglected cost on ongoing task performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.