208 resultados para pelvic motion

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acetabular retroversion following acetabular osteotomy in hips with dysplasia can negatively effect the outcome. Total retroversion, where the entire anterior rim is lateral to the posterior rim, is rare and can easily be missed on pelvic radiographs due to the lack of a crossover sign. We evaluated the clinical and radiographic presentation, the surgical management, and the outcome of hips with total acetabular retroversion. We retrospectively reviewed 26 patients (26 hips) with total retroversion following 15 periacetabular osteotomies (PAO), 10 triple type, and one Salter osteotomy. We obtained range of motion (ROM), anterior impingement test, Drehmann's sign, Merle d’Aubigné-Postel score, and Tönnis score for osteoarthrosis. Corrective surgery included 19 revision PAOs and seven total hip arthroplasties (THA). The mean follow-up was 4.7 ± 4.2 (range 0.5-13.8) years. Patients presented with a restricted ROM (flexion and internal rotation), a positive anterior impingement test, a positive Drehmann's sign, and a decreased Merle d'Aubigné-Postel score due to pain. Corrective surgery was performed after mean of 7 ± 5 (1-15) years. Complications for revision PAO and THA occurred in 37% and 29%, respectively. At follow-up, the Merle d'Aubigné-Postel score improved for both revision PAOs and THAs. The prevalence of a positive anterior impingement test and Drehmann's sign decreased for revision PAOs. There was a tendency for progression of OA in hips with revision PAO. Iatrogenic total acetabular retroversion following reorientation is a disabling condition for the patients. Corrective surgery including revision PAO and THA results in improved clinical outcome. However, these procedures are technically challenging and associated with high complication rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the number of lymph nodes and the lymph node tumour burden in different anatomical pelvic regions to better asses the impact of variations in the extent of lymphadenectomy on reported LN parameters and pelvic tumour clearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the field of computer assisted orthopedic surgery (CAOS) the anterior pelvic plane (APP) is a common concept to determine the pelvic orientation by digitizing distinct pelvic landmarks. As percutaneous palpation is - especially for obese patients - known to be error-prone, B-mode ultrasound (US) imaging could provide an alternative means. Several concepts of using ultrasound imaging to determine the APP landmarks have been introduced. In this paper we present a novel technique, which uses local patch statistical shape models (SSMs) and a hierarchical speed of sound compensation strategy for an accurate determination of the APP. These patches are independently matched and instantiated with respect to associated point clouds derived from the acquired ultrasound images. Potential inaccuracies due to the assumption of a constant speed of sound are compensated by an extended reconstruction scheme. We validated our method with in-vitro studies using a plastic bone covered with a soft-tissue simulation phantom and with a preliminary cadaver trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the ischial spine sign (ISS) has been advocated to detect acetabular retroversion, it is unknown whether the sign is valid on anteroposterior (AP) pelvic radiographs with tilted or rotated pelves. We therefore evaluated reliability of the ISS as a tool for diagnosing acetabular retroversion in the presence of considerable pelvic tilt and/or malrotation. We obtained radiographs of 20 cadaver pelves in 19 different malorientations resulting in 380 pelvis images (760 hips) for evaluation. In addition, 129 clinical radiographs of patients' hips that had varying pelvis orientations were reviewed. We found an overall sensitivity of 81% (90%), specificity of 70% (71%), positive predictive value of 77% (80.7%), and negative predictive value of 75% (85%) in the cadaver (patient) hips. Our data suggest the ISS is a valid tool for diagnosing acetabular retroversion on plain radiographs taken using a standardized technique regardless of the degree of pelvic tilt and rotation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gross dissection for demonstrating anatomy of the human pelvis has traditionally involved one of two approaches, each with advantages and disadvantages. Classic hemisection in the median plane through the pelvic ring transects the visceral organs but maintains two symmetric pelvic halves. An alternative paramedial transection compromises one side of the bony pelvis but leaves the internal organs intact. The authors propose a modified technique that combines advantages of both classical dissections. This novel approach involves dividing the pubic symphysis and sacrum in the median plane after shifting all internal organs to one side. The hemipelvis without internal organs is immediately available for further dissection of the lower limb. The hemipelvis with intact internal organs is ideal for showing the complex spatial relationships of the pelvic organs and vessels relative to the intact pelvic floor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Major pelvic trauma results in high mortality. No standard technique to control pelvic hemorrhage has been identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prolonged postoperative pain and delayed intestinal transit are frequent problems following extended pelvic lymph-node dissection (PLND) and cystectomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fully controlled liquid injection and flow in hydrophobic polydimethylsiloxane (PDMS) two-dimensional microchannel arrays based on on-chip integrated, low-voltage-driven micropumps are demonstrated. Our architecture exploits the surface-acoustic-wave (SAW) induced counterflow mechanism and the effect of nebulization anisotropies at crossing areas owing to lateral propagating SAWs. We show that by selectively exciting single or multiple SAWs, fluids can be drawn from their reservoirs and moved towards selected positions of a microchannel grid. Splitting of the main liquid flow is also demonstrated by exploiting multiple SAW beams. As a demonstrator, we show simultaneous filling of two orthogonal microchannels. The present results show that SAW micropumps are good candidates for truly integrated on-chip fluidic networks allowing liquid control in arbitrarily shaped two-dimensional microchannel arrays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment, is predominantly a domain of in vitro experiments on spinal loading simulators. Most existing approaches to measure spinal stiffness intraoperatively in an in vivo environment use a distractor. However, these concepts usually assume a planar loading and motion. The objective of our study was to develop and validate an apparatus, that allows to perform intraoperative in vivo measurements to determine both the applied force and the resulting motion in three dimensional space. The proposed setup combines force measurement with an instrumented distractor and motion tracking with an optoelectronic system. As the orientation of the applied force and the three dimensional motion is known, not only force-displacement, but also moment-angle relations could be determined. The validation was performed using three cadaveric lumbar ovine spines. The lateral bending stiffness of two motion segments per specimen was determined with the proposed concept and compared with the stiffness acquired on a spinal loading simulator which was considered to be gold standard. The mean values of the stiffness computed with the proposed concept were within a range of ±15% compared to data obtained with the spinal loading simulator under applied loads of less than 5 Nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the expression of the 5-hydroxytryptamine 4 (5-HT4) receptor subtype and investigate the modulating function of those receptors on contractility in intestinal tissues obtained from horses without gastrointestinal tract disease. SAMPLE POPULATION: Smooth muscle preparations from the duodenum, ileum, and pelvic flexure collected immediately after slaughter of 24 horses with no history or signs of gastrointestinal tract disease. PROCEDURES: In isometric organ baths, the contractile activities of smooth muscle preparations in response to 5-hydroxytryptamine and electric field stimulation were assessed; the effect of tegaserod alone or in combination with 5-hydroxytryptamine on contractility of intestinal specimens was also investigated. Presence and distribution of 5-HT4 receptors in intestinal tissues and localization on interstitial cells of Cajal were examined by use of an immunofluorescence technique. RESULTS: Widespread 5-HT4 receptor immunoreactivity was observed in all intestinal smooth muscle layers; 5-HT4 receptors were absent from the myenteric plexus and interstitial cells of Cajal. In electrical field-stimulated tissue preparations of duodenum and pelvic flexure, tegaserod increased the amplitude of smooth muscle contractions in a concentration-dependent manner. Preincubation with tegaserod significantly decreased the basal tone of the 5-HT-evoked contractility in small intestine specimens, compared with the effect of 5-HT alone, thereby confirming that tegaserod was acting as a partial agonist. CONCLUSIONS AND CLINICAL RELEVANCE: In horses, 5-HT4 receptors on smooth muscle cells appear to be involved in the contractile response of the intestinal tract to 5-hydroxytryptamine. Results suggest that tegaserod may be useful for treatment of reduced gastrointestinal tract motility in horses.