6 resultados para peak capacity
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Over the past decades, major progress in patient selection, surgical techniques and anaesthetic management have largely contributed to improved outcome in lung cancer surgery. The purpose of this study was to identify predictors of post-operative cardiopulmonary morbidity in patients with a forced expiratory volume in 1 s <80% predicted, who underwent cardiopulmonary exercise testing (CPET). In this observational study, 210 consecutive patients with lung cancer underwent CPET with completed data over a 9-yr period (2001-2009). Cardiopulmonary complications occurred in 46 (22%) patients, including four (1.9%) deaths. On logistic regression analysis, peak oxygen uptake (peak V'(O₂) and anaesthesia duration were independent risk factors of both cardiovascular and pulmonary complications; age and the extent of lung resection were additional predictors of cardiovascular complications, whereas tidal volume during one-lung ventilation was a predictor of pulmonary complications. Compared with patients with peak V'(O₂) >17 mL·kg⁻¹·min⁻¹, those with a peak V'(O₂) <10 mL·kg⁻¹·min⁻¹ had a four-fold higher incidence of cardiac and pulmonary morbidity. Our data support the use of pre-operative CPET and the application of an intra-operative protective ventilation strategy. Further studies should evaluate whether pre-operative physical training can improve post-operative outcome.
Resumo:
The objective of this study was to determine the effect of wearing a mouthguard on maximal exercise capacity and cardiopulmonary parameters at peak workload, and to assess the athletes' attitudes toward wearing a mouthguard. Thirteen volunteer male athletes (18 to 27 years old) were interviewed before and after delivery of a custom-made laminated mouthguard. A visual analogue scale (VAS, 0 - 100 mm) was used for judgment of interference with breathing, speaking, concentration and athletic performance. In addition, the athletes were subjected to a cardiorespiratory examination on a cycle ergometer with and without mouthguards. Subjectively, the athletes rated the mean interference with performance to be 37 mm VAS at the beginning of the study. Mean scores of impairment decreased to 23 mm VAS (p = 0.081) after wearing the mouthguard for four weeks, and further improved to 12 mm VAS (p < 0.001) after the test on the cycle ergometer. Objectively, the maximum workload during spiroergometry was even slightly elevated during exercise with the mouthguard (330.2 W) compared to exercise without the mouthguard (314.5 W). Peak minute ventilation and oxygen uptake were not different during exercise with and without the mouthguard. The present study demonstrated that a custom-made mouthguard does not significantly affect or reduce maximum exercise performance of athletes.
Resumo:
BACKGROUND: Adult patients with repaired tetralogy of Fallot (rTOF) often have diminished exercise capacity. The primary objective of this study was to examine whether abnormalities of biventricular function play a role in exercise limitation in patients with rTOF. METHODS: This was a retrospective review of 99 adult patients with rTOF. Right ventricular (RV) and left ventricular (LV) function were assessed echocardiographically using the myocardial performance index (MPI). Maximal oxygen consumption (VO(2) Max) was measured during a level 1 cardiopulmonary exercise test. RESULTS: The mean age of the cohort was 34 +/- 11 years (50% females). Although most of the patients reported good functional capacity, the peak Vo(2)max was decreased at 22 +/- 6 mL/kg per minute (66% +/- 13% predicted Vo(2)max for age and sex). The mean RV and LV MPI were 0.30 +/- 0.07 and 0.42 +/- 0.09, respectively. In the multivariate model, higher RV MPI (P = .04) and LV MPI (P = .005) values, representing impaired ventricular function, were associated with diminished Vo(2)max. There was a significant correlation between the RV and LV MPI (r = 0.54, P = .001). CONCLUSIONS: Impairment of RV and LV function, as measured by MPI, is associated with diminished exercise capacity in patients with repaired tetralogy of Fallot. Furthermore, there is a linear relationship between the RV and LV function suggesting that ventricular interactions are contributing to the limited exercise capacity in this group of patients. Strategies aimed at preserving biventricular function or improving adverse ventricular interactions could help to improve functional capacity in these patients.
Resumo:
BACKGROUND: Exercise capacity after heart transplantation (HTx) remains limited despite normal left ventricular systolic function of the allograft. Various clinical and haemodynamic parameters are predictive of exercise capacity following HTx. However, the predictive significance of chronotropic competence has not been demonstrated unequivocally despite its immediate relevance for cardiac output. AIMS: This study assesses the predictive value of various clinical and haemodynamic parameters for exercise capacity in HTx recipients with complete chronotropic competence evolving within the first 6 postoperative months. METHODS: 51 patients were enrolled in this exercise study. Patients were included when at least >6 months after HTx and without negative chronotropic medication or factors limiting exercise capacity such as significant transplant vasculopathy or allograft rejection. Clinical parameters were obtained by chart review, haemodynamic parameters from current cardiac catheterisation, and exercise capacity was assessed by treadmill stress testing. A stepwise multiple regression model analysed the proportion of the variance explained by the predictive parameters. RESULTS: The mean age of these 51 HTx recipients was 55.4 +/- 13.2 yrs on inclusion, 42 pts were male and the mean time interval after cardiac transplantation was 5.1 +/- 2.8 yrs. Five independent predictors explained 47.5% of the variance observed for peak exercise capacity (adjusted R2 = 0.475). In detail, heart rate response explained 31.6%, male gender 5.2%, age 4.1%, pulmonary vascular resistance 3.7%, and body-mass index 2.9%. CONCLUSION: Heart rate response is one of the most important predictors of exercise capacity in HTx recipients with complete chronotropic competence and without relevant transplant vasculopathy or acute allograft rejection.
Resumo:
BACKGROUND: Peak oxygen uptake (peak Vo(2)) is an established integrative measurement of maximal exercise capacity in cardiovascular disease. After heart transplantation (HTx) peak Vo(2) remains reduced despite normal systolic left ventricular function, which highlights the relevance of diastolic function. In this study we aim to characterize the predictive significance of cardiac allograft diastolic function for peak Vo(2). METHODS: Peak Vo(2) was measured using a ramp protocol on a bicycle ergometer. Left ventricular (LV) diastolic function was assessed with tissue Doppler imaging sizing the velocity of the early (Ea) and late (Aa) apical movement of the mitral annulus, and conventional Doppler measuring early (E) and late (A) diastolic transmitral flow propagation. Correlation coefficients were calculated and linear regression models fitted. RESULTS: The post-transplant time interval of the 39 HTxs ranged from 0.4 to 20.1 years. The mean age of the recipients was 55 +/- 14 years and body mass index (BMI) was 25.4 +/- 3.9 kg/m(2). Mean LV ejection fraction was 62 +/- 4%, mean LV mass index 108 +/- 22 g/m(2) and mean peak Vo(2) 20.1 +/- 6.3 ml/kg/min. Peak Vo(2) was reduced in patients with more severe diastolic dysfunction (pseudonormal or restrictive transmitral inflow pattern), or when E/Ea was > or =10. Peak Vo(2) correlated with recipient age (r = -0.643, p < 0.001), peak heart rate (r = 0.616, p < 0.001) and BMI (r = -0.417, p = 0.008). Of all echocardiographic measurements, Ea (r = 0.561, p < 0.001) and Ea/Aa (r = 0.495, p = 0.002) correlated best. Multivariate analysis identified age, heart rate, BMI and Ea/Aa as independent predictors of peak Vo(2). CONCLUSIONS: Diastolic dysfunction is relevant for the limitation of maximal exercise capacity after HTx.
Resumo:
OBJECTIVE To determine the short- and long-term effects of an intensive, concentrated rehabilitation programme in patients with chronic heart failure. DESIGN Randomized controlled trial, with one-month and six-year evaluations. SETTING Residential rehabilitation centre in Switzerland. SUBJECTS Fifty patients with chronic heart failure, randomized to exercise or control groups. INTERVENTIONS A rehabilitation programme lasting one month, including educational sessions, a low-fat diet, and 2 hours of individually prescribed exercise daily. MAIN MEASURES Exercise test responses, health outcomes and physical activity patterns. RESULTS Peak Vo(2) increased 21.4% in the exercise group during the rehabilitation programme (P<0.05), whereas peak Vo(2) did not change among controls. After the six-year follow-up period, peak Vo(2) was only slightly higher than that at baseline in the trained group (7%, NS), while peak Vo(2) among controls was unchanged. During long-term follow-up, 9 and 12 patients died in the exercise and control groups, respectively (P = 0.63). At six years, physical activity patterns tended to be higher in the exercise group; the mean energy expenditure values over the last year were 2,704 +/- 1,970 and 2,085 +/- 1,522 kcal/week during recreational activities for the exercise and control groups, respectively. However, both groups were more active compared to energy expenditure prior to their cardiac event (P<0.001). CONCLUSIONS Six years after participation in a residential rehabilitation programme, patients with chronic heart failure had slightly better outcomes than control subjects, maintained exercise capacity and engaged in activities that exceed the minimal amount recommended by guidelines for cardiovascular health.