17 resultados para partial pressure

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake by ventilation and delivery by perfusion, to quantify the ventilation-perfusion ratio (Va/Q) of a lung region: The mixed venous blood and the inspiratory oxygen fraction, which are equal for all lung regions, are measured. In addition, the local expiratory oxygen fraction and the end capillary oxygen content, both of which may differ between the lung regions, are calculated using the fMRI-detected Pao(2). We investigated this approach by numerical simulations and applied it to quantify local Va/Q in the perfluorocarbons during partial liquid ventilation. METHODS: Numerical simulations were performed to analyze the sensitivity of the Va/Q calculation and to compare this approach with another one proposed by Rizi et al. in 2004 (Magn Reson Med 2004;52:65-72). Experimentally, the method was used during partial liquid ventilation in 7 anesthetized pigs. The Pao(2) distribution in intraalveolar perflubron was measured by fluorine-19 MRI. Respiratory gas fractions together with arterial and mixed venous blood samples were taken to quantify oxygen partial pressure and content. Using the Fick principle, the local Va/Q was estimated. The impact of gravity (nondependent versus dependent) of perflubron dose (10 vs 20 mL/kg body weight) and of inspired oxygen fraction (Fio(2)) (0.4-1.0) on Va/Q was examined. RESULTS: In numerical simulations, the Fick principle proved to be appropriate over the Va/Q range from 0.02 to 2.5. Va/Q values were in acceptable agreement with the method published by Rizi et al. In the experimental setting, low mean Va/Q values were found in perflubron (confidence interval [CI] 0.08-0.29 with 20 mL/kg perflubron). At this dose, Va/Q in the nondependent lung was higher (CI 0.18-0.39) than in the dependent lung regions (CI 0.06-0.16; P = 0.006; Student t test). Differences depending on Fio(2) or perflubron dose were, however, small. CONCLUSION: The results show that derivation of Va/Q from local Po(2) measurements using fMRI in perflubron is feasible. The low detected Va/Q suggests that oxygen transport into the perflubron-filled alveolar space is significantly restrained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Water vapour, despite being a minor constituent in the Martian atmosphere with its precipitable amount of less than 70 pr. μm, attracts considerable attention in the scientific community because of its potential importance for past life on Mars. The partial pressure of water vapour is highly variable because of its seasonal condensation onto the polar caps and exchange with a subsurface reservoir. It is also known to drive photochemical processes: photolysis of water produces H, OH, HO2 and some other odd hydrogen compounds, which in turn destroy ozone. Consequently, the abundance of water vapour is anti-correlated with ozone abundance. The Herschel Space Observatory provides for the first time the possibility to retrieve vertical water profiles in the Martian atmosphere. Herschel will contribute to this topic with its guaranteed-time key project called "Water and related chemistry in the solar system". Observations of Mars by Heterodyne Instrument for the Far Infrared (HIFI) and Photodetector Array Camera and Spectrometer (PACS) onboard Herschel are planned in the frame of the programme. HIFI with its high spectral resolution enables accurate observations of vertically resolved H2O and temperature profiles in the Martian atmosphere. Unlike HIFI, PACS is not capable of resolving the line-shape of molecular lines. However, our present study of PACS observations for the Martian atmosphere shows that the vertical sensitivity of the PACS observations can be improved by using multiple-line observations with different line opacities. We have investigated the possibility of retrieving vertical profiles of temperature and molecular abundances of minor species including H2O in the Martian atmosphere using PACS. In this paper, we report that PACS is able to provide water vapour vertical profiles for the Martian atmosphere and we present the expected spectra for future PACS observations. We also show that the spectral resolution does not allow the retrieval of several studied minor species, such as H2O2, HCl, NO, SO2, etc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Small animal models are widely used in basic research. However, experimental systems requiring extracorporeal circuits are frequently confronted with limitations related to equipment size. This is particularly true for oxygenators in systems with limited volumes. Thus we aimed to develop and validate an ultra mini-oxygenator for low-volume, buffer-perfused systems. Methods: We have manufactured a series of ultra mini-oxygenators with approximately 175 aligned, microporous, polypropylene hollow fibers contained inside a shell, which is sealed at each of the two extremities to isolate perfusate and gas compartments. With this construction, gas passes through hollow fibers, while perfusate circulates around fibers. Performance of ultra mini-oxygenators (oxygen partial pressure (PO2 ), gas and perfusate flow, perfusate pressure and temperature drop) were assessed with modified Krebs-Henseleit buffer in an in vitro perfusion circuit and an ex vivo rat heart preparation. Results: Mean priming volume of ultra mini-oxygenators was 1.2±0.5 mL and, on average, 86±6% of fibers were open (n=17). In vitro, effective oxygenation (PO2=400-500 mmHg) was achieved for all flow rates up to 50 mL/min and remained stable for at least 2 hours (n=5). Oxygenation was also effective and stable (PO2=456±40 mmHg) in the isolated heart preparation for at least 60 minutes ("venous" PO2=151±11 mmHg; n=5). Conclusions: We have established a reproducible procedure for fabrication of ultra mini-oxygenators, which provide reliable and stable oxygenation for at least 60-120 min. These oxygenators are especially attractive for pre-clinical protocols using small, rather than large, animals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Pneumocystis jiroveci pneumonia (PCP) remains the most common opportunistic infection in patients infected with the human immunodeficiency virus (HIV). Among patients with HIV infection and PCP the mortality rate is 10 to 20% during the initial infection and increases substantially with the need for mechanical ventilation. It was suggested that in these patients corticosteroids adjunctive to standard treatment for PCP could prevent the need for mechanical ventilation and decrease mortality. OBJECTIVES: To assess the effects of adjunctive corticosteroids on overall mortality and the need for mechanical ventilation in HIV-infected patients with PCP and substantial hypoxemia (arterial oxygen partial pressure <70 mmHg or alveolar-arterial gradient >35 mmHg on room air). SEARCH STRATEGY: We searched Medline (January 1980-December 2004), EMBASE (January 1985-December 2004) and The Cochrane Library (Issue 4, 2004) without language restrictions to identify randomised controlled trials that compared adjunctive corticosteroids to control in HIV-infected patients with PCP. We further reviewed the reference lists from previously published overviews, we searched UptoDate version 2005 and Clinical Evidence Concise (Issue 12, 2004), contacted experts of the field, and searched reference lists of identified publications for citations of additional relevant articles. SELECTION CRITERIA: Trials were considered eligible for this review if they compared corticosteroids to placebo or usual care in HIV-infected patients with PCP in addition to baseline treatment with trimethoprim-sulfamethoxazole, pentamidine or dapsone-trimethoprim, used random allocation, and reported mortality data. We excluded trials in patients with no or mild hypoxemia (arterial oxygen partial pressure >70 mmHg or an alveolar-arterial gradient <35 mmHg on room air) and trials with a follow-up of less than 30 days. DATA COLLECTION AND ANALYSIS: Two teams of reviewers independently evaluated the methodology and extracted data from each primary study. We pooled treatment effects across studies and calculated a weighted average risk ratio of overall mortality in the treatment and control groups by using a random effects model. MAIN RESULTS: Six studies were included in the review and meta-analysis. Risk ratios for overall mortality for adjunctive corticosteroids were 0.56 (95% confidence interval [CI], 0.32-0.98) at 1 month and 0.68 (95% CI, 0.50-0.94) at 3-4 months of follow-up. To prevent 1 death, numbers needed to treat are 9 patients in a setting without highly active antiretroviral therapy (HAART) available, and 23 patients with HAART available. Only the 3 largest trials provided data on the need for mechanical ventilation with a risk ratio of 0.38 (95% CI, 0.20-0.73) in favour of adjunctive corticosteroids. AUTHORS' CONCLUSIONS: The number and size of trials investigating adjunctive corticosteroids for HIV-infected patients with PCP is small, but evidence from this review suggests a beneficial effect for patients with substantial hypoxemia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The arterial pharmacokinetics of ketamine and norketamine enantiomers after racemic ketamine or S-ketamine i.v. administration were evaluated in seven gelding ponies in a crossover study (2-month interval). METHODS: Anaesthesia was induced with isoflurane in oxygen via a face-mask and then maintained at each pony's individual MAC. Racemic ketamine (2.2 mg kg(-1)) or S-ketamine (1.1 mg kg(-1)) was injected in the right jugular vein. Blood samples were collected from the right carotid artery before and at 1, 2, 4, 8, 16, 32, 64, and 128 min after ketamine administration. Ketamine and norketamine enantiomer plasma concentrations were determined by capillary electrophoresis. Individual R-ketamine and S-ketamine concentration vs time curves were analysed by non-linear least square regression two-compartment model analysis using PCNonlin. Plasma disposition curves for R-norketamine and S-norketamine were described by estimating AUC, C(max), and T(max). Pulse rate (PR), respiratory rate (R(f)), tidal volume (V(T)), minute volume ventilation (V(E)), end-tidal partial pressure of carbon dioxide (PE'(CO(2))), and mean arterial blood pressure (MAP) were also evaluated. RESULTS: The pharmacokinetic parameters of S- and R-ketamine administered in the racemic mixture or S-ketamine administered separately did not differ significantly. Statistically significant higher AUC and C(max) were found for S-norketamine compared with R-norketamine in the racemic group. Overall, R(f), V(E), PE'(CO(2)), and MAP were significantly higher in the racemic group, whereas PR was higher in the S-ketamine group. CONCLUSIONS: Norketamine enantiomers showed different pharmacokinetic profiles after single i.v. administration of racemic ketamine in ponies anaesthetised with isoflurane in oxygen (1 MAC). Cardiopulmonary variables require further investigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Oxygen-sensitive 3He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO2) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acqiured on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n = 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Wound infection remains a common and serious complication after colonic surgery. Although many colonic operations are performed laparoscopically, it remains unclear whether this has any impact on the incidence of wound infection. Subcutaneous tissue oxygenation is an excellent predictor of surgical wound infection. The impact of open and laparoscopic colonic surgery on tissue oxygenation was compared. METHODS: Fifty-two patients undergoing elective open and laparoscopic left-sided colonic resections were evaluated in a prospective observational study. Anaesthesia management was standardized and intraoperative arterial partial pressure of oxygen was kept at 150 mmHg in both groups. Oxygen tension was measured in the subcutaneous tissue of the right upper arm. RESULTS: At the start of surgery subcutaneous tissue oxygen tension (PsqO(2)) was similar in both groups (mean(s.d.) 65.8(17.2) and 63.7(23.6) mmHg for open and laparoscopic operations respectively; P = 0.714). Tissue oxygen remained stable in the open group, but dropped significantly in the laparoscopic group during the course of surgery (PsqO(2) after operation 53.4(12.9) and 45.5(11.6) mmHg, respectively; P = 0.012). CONCLUSION: Laparoscopic colonic surgery significantly decreases PsqO(2), an effect that occurs early in the course of surgery. As tissue oxygen tension is a predictor of wound infection, these results may explain why the risk of wound infection after laparoscopic surgery remains higher than expected.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The objective of this study was to review the effects of adjunctive corticosteroids on overall mortality and the need for mechanical ventilation in HIV-infected patients with Pneumocystis jiroveci pneumonia (PCP) and substantial hypoxemia (arterial oxygen partial pressure <70 mmHg or alveolar-arterial gradient >35 mmHg on room air). METHODS: We conducted a systematic search of the literature for randomised trials published up to December 2004. Selected trials compared adjunctive corticosteroids with placebo or usual care in HIV-infected patients with PCP and reported mortality data. Two teams of reviewers independently evaluated the methodology and extracted data from each primary study. RESULTS: Six studies were included in the meta-analysis. Risk ratios for overall mortality for adjunctive corticosteroids were 0.54 (95% confidence interval [CI], 0.38-0.79) at 1 month and 0.67 (95% CI, 0.49-0.93) at 3-4 months of follow-up. Numbers needed to treat, to prevent 1 death, are 9 patients in a setting without highly active antiretroviral therapy (HAART) available and 22 patients with HAART available. Only the 3 largest trials provided data on the need for mechanical ventilation with a risk ratio of 0.37 (95% CI, 0.20-0.70) in favour of adjunctive corticosteroids. CONCLUSION: The number and size of trials investigating adjunctive corticosteroids for HIV-infected patients with PCP is small, but our results suggest a beneficial effect for patients with substantial hypoxemia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND The development of metabolic alkalosis was described recently in patients with hypernatremia. However, the causes for this remain unknown. The current study serves to clarify whether metabolic alkalosis develops in vitro after removal of free water from plasma and whether this can be predicted by a mathematical model. MATERIALS AND METHODS Ten serum samples of healthy humans were dehydrated by 29 % by vacuum centrifugation corresponding to an increase of the contained concentrations by 41 %. Constant partial pressure of carbon dioxide at 40 mmHg was simulated by mathematical correction of pH [pH(40)]. Metabolic acid-base state was assessed by Gilfix' base excess subsets. Changes of acid-base state were predicted by the physical-chemical model according to Watson. RESULTS Evaporation increased serum sodium from 141 (140-142) to 200 (197-203) mmol/L, i.e., severe hypernatremia developed. Acid-base analyses before and after serum concentration showed metabolic alkalosis with alkalemia: pH(40): 7.43 (7.41 to 7.45) vs 7.53 (7.51 to 7.55), p = 0.0051; base excess: 1.9 (0.7 to 3.6) vs 10.0 (8.2 to 11.8), p = 0.0051; base excess of free water: 0.0 (- 0.2 to 0.3) vs 17.7 (16.8 to 18.6), p = 0.0051. The acidifying effects of evaporation, including hyperalbuminemic acidosis, were beneath the alkalinizing ones. Measured and predicted acid-base changes due to serum evaporation agreed well. CONCLUSIONS Evaporation of water from serum causes concentrational alkalosis in vitro, with good agreement between measured and predicted acid-base values. At least part of the metabolic alkalosis accompanying hypernatremia is independent of renal function.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim was to investigate the effect of mechanical pain stimulation at the lower back on hemodynamic and oxygenation changes in the prefrontal cortex (PFC) assessed by functional near-infrared spectroscopy (fNIRS) and on the partial pressure of end-tidal carbon dioxide ( PetCO 2) measured by capnography. 13 healthy subjects underwent three measurements (M) during pain stimulation using pressure pain threshold (PPT) at three locations, i.e., the processus spinosus at the level of L4 (M1) and the lumbar paravertebral muscles at the level of L1 on the left (M2) and the right (M3) side. Results showed that only in the M2 condition the pain stimulation elicited characteristic patterns consisting of (1) a fNIRS-derived decrease in oxy- and total hemoglobin concentration and tissue oxygen saturation, an increase in deoxy-hemoglobin concentration, (2) a decrease in the PetCO 2 response and (3) a decrease in coherence between fNIRS parameters and PetCO 2 responses in the respiratory frequency band (0.2-0.5 Hz). We discuss the comparison between M2 vs. M1 and M3, suggesting that the non-significant findings in the two latter measurements were most likely subject to effects of the different stimulated tissues, the stimulated locations and the stimulation order. We highlight that PetCO 2 is a crucial parameter for proper interpretation of fNIRS data in experimental protocols involving pain stimulation. Together, our data suggest that the combined fNIRS-capnography approach has potential for further development as pain monitoring method, such as for evaluating clinical pain treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction In several studies, we found that during guided rhythmic speech exercises, a decrease in cerebral hemodynamics and oxygenation occurred as the result of a decrease in the partial pressure of carbon dioxide in the arterial blood (PaCO2) during speaking. To further explore the effect of PaCO2 variations on cerebral hemodynamics and oxygenation, the aim of the present study was to investigate the impact of spoken, inner and heard speech tasks on these parameters. Material and Methods Speech tasks included recitation or inner recitation or listening to hexameter, alliteration, prose, or performing mental arithmetic. The following physiological parameters were measured: tissue oxygen saturation (StO2) and absolute concentrations of oxyhemoglobin, deoxyhemoglobin, total hemoglobin (over the left and right anterior prefrontal cortex, using an ISS OxiplexTS frequency domain near-infrared spectrometer) and end-tidal CO2 (PETCO2; using Nellcor N1000 and Datex NORMOCAP capnographs). Statistical analysis was applied to the differences between baseline, 2 tasks, and 3 post-baseline periods. Data of 3 studies with 24, 7 and 29 healthy subjects, respectively, were combined, and linear regression analyses were calculated. Results Linear regression analyses revealed significant relations between changes in oxyhemoglobin, deoxyhemoglobin, total hemoglobin or StO2 and the participants’ age, the baseline PETCO2 or certain speech tasks. While hexameter verses affected changes during the tasks, alliteration verses only affected changes during the recovery phase. Discussion and Conclusion The observed effects in hemodynamics and oxygenation indicate a combination of neurovascular coupling (increased neuronal activity leading to an increase in the cerebral metabolic rate of oxygen resulting in an increase in cerebral flood flow/volume) and CO2 reactivity (increased breathing during speech tasks causing a decrease in PaCO2 leading to vasoconstriction and decrease in cerebral blood flow). The neurovascular coupling characteristics are task-dependent. References Scholkmann F, Gerber U, Wolf M, Wolf U. End-tidal CO2: An important parameter for a correct interpretation in functional brain studies using speech tasks. Neuroimage 2013;66:71-79. Scholkmann F, Wolf M, Wolf U. The effect of inner speech on arterial CO2, cerebral hemodynamics and oxygenation – A functional NIRS study. Adv Exp Med Biol 2013;789:81-87.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to validate oxygen-sensitive 3He-MRI in noninvasive determination of the regional, two- and three-dimensional distribution of oxygen partial pressure. In a gas-filled elastic silicon ventilation bag used as a lung phantom, oxygen sensitive two- and three-dimensional 3He-MRI measurements were performed at different oxygen concentrations which had been equilibrated in a range of normal and pathologic values. The oxygen partial pressure distribution was determined from 3He-MRI using newly developed software allowing for mapping of oxygen partial pressure. The reference bulk oxygen partial pressure inside the phantom was measured by conventional respiratory gas analysis. In two-dimensional measurements, image-based and gas-analysis results correlated with r=0.98; in three-dimensional measurements the between-methods correlation coefficient was r=0.89. The signal-to-noise ratio of three-dimensional measurements was about half of that of two-dimensional measurements and became critical (below 3) in some data sets. Oxygen-sensitive 3He-MRI allows for noninvasive determination of the two- and three-dimensional distribution of oxygen partial pressure in gas-filled airspaces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Pneumocystis jiroveci pneumonia (PCP) remains the most common opportunistic infection in patients infected with the human immunodeficiency virus (HIV). Among patients with HIV infection and PCP the mortality rate is 10% to 20% during the initial infection and this increases substantially with the need for mechanical ventilation. It has been suggested that corticosteroids adjunctive to standard treatment for PCP could prevent the need for mechanical ventilation and decrease mortality in these patients. OBJECTIVES To assess the effects of adjunctive corticosteroids on overall mortality and the need for mechanical ventilation in HIV-infected patients with PCP and substantial hypoxaemia (arterial oxygen partial pressure < 70 mmHg or alveolar-arterial gradient > 35 mmHg on room air). SEARCH METHODS For the original review we searched The Cochrane Library (2004, Issue 4), MEDLINE (January 1980 to December 2004) and EMBASE (January 1985 to December 2004) without language restrictions. We further reviewed the reference lists from previously published overviews, searched UptoDate version 2005 and Clinical Evidence Concise (Issue 12, 2004), contacted experts in the field and searched the reference lists of identified publications for citations of additional relevant articles.In this update of our review, we searched the above-mentioned databases in September 2010 and April 2014 for trials published since our original review. We also searched for ongoing trials in ClinicalTrials.gov and the World Health Organization International Clinical Trial Registry Platform (ICTRP). We searched for conference abstracts via AEGIS. SELECTION CRITERIA Randomised controlled trials that compared corticosteroids to placebo or usual care in HIV-infected patients with PCP in addition to baseline treatment with trimethoprim-sulfamethoxazole, pentamidine or dapsone-trimethoprim, and reported mortality data. We excluded trials in patients with no or mild hypoxaemia (arterial oxygen partial pressure > 70 mmHg or an alveolar-arterial gradient < 35 mmHg on room air) and trials with a follow-up of less than 30 days. DATA COLLECTION AND ANALYSIS Two teams of review authors independently evaluated the methodology and extracted data from each primary study. We pooled treatment effects across studies and calculated a weighted average risk ratio of overall mortality in the treatment and control groups using a random-effects model.In this update of our review, we used the GRADE methodology to assess evidence quality. MAIN RESULTS Of 2029 screened records, we included seven studies in the review and six in the meta-analysis. Risk of bias varied: the randomisation and allocation process was often not clearly described, five of seven studies were double-blind and there was almost no missing data. The quality of the evidence for mortality was high. Risk ratios for overall mortality for adjunctive corticosteroids were 0.56 (95% confidence interval (CI) 0.32 to 0.98) at one month and 0.59 (95% CI 0.41 to 0.85) at three to four months of follow-up. In adults, to prevent one death, numbers needed to treat are nine patients in a setting without highly active antiretroviral therapy (HAART) available, and 23 patients with HAART available. The three largest trials provided moderate quality data on the need for mechanical ventilation, with a risk ratio of 0.38 (95% CI 0.20 to 0.73) in favour of adjunctive corticosteroids. One study was conducted in infants, suggesting a risk ratio for death in hospital of 0.81 (95% CI 0.51 to 1.29; moderate quality evidence). AUTHORS' CONCLUSIONS The number and size of trials investigating adjunctive corticosteroids for HIV-infected patients with PCP is small, but the evidence from this review suggests a beneficial effect for adult patients with substantial hypoxaemia. There is insufficient evidence on the effect of adjunctive corticosteroids on survival in infants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Primary hyperventilation is defined as a state of alveolar ventilation in excess of metabolic requirements, leading to decreased arterial partial pressure of carbon dioxide. The primary aim of this study was to characterise patients diagnosed with primary hyperventilation in the ED. METHODS Our retrospective cohort study comprised adult (≥16 years) patients admitted to our ED between 1 January 2006 and 31 December 2012 with the primary diagnosis of primary (=psychogenic) hyperventilation. RESULTS A total of 616 patients were eligible for study. Participants were predominantely female (341 [55.4%] female versus 275 [44.6%] male respectively, p <0.01). The mean age was 36.5 years (SD 15.52, range 16-85). Patients in their twenties were the most common age group (181, 29.4%), followed by patients in their thirties (121, 19.6%). Most patients presented at out-of-office hours (331 [53.7%]. The most common symptom was fear (586, 95.1%), followed by paraesthesia (379, 61.5%) and dizziness (306, 49.7%). Almost a third (187, 30.4%) of our patients had previously experienced an episode of hyperventilation and half (311, 50.5%) of patients had a psychiatric co-morbidity. CONCLUSION Hyperventilation is a diagnostic chimera with a wide spectrum of symptoms. Patients predominantly are of young age, female sex and often have psychiatric comorbidities. The severity of symptoms accompanied with primary hyperventilation most often needs further work-up to rule out other diagnosis in a mostly young population. In the future, further prospective multicentre studies are needed to evaluate and establish clear diagnostic criteria for primary hyperventilation and possible screening instruments.