52 resultados para parabolic mirror

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper a new 22 GHz water vapor spectro-radiometer which has been specifically designed for profile measurement campaigns of the middle atmosphere is presented. The instrument is of a compact design and has a simple set up procedure. It can be operated as a standalone instrument as it maintains its own weather station and a calibration scheme that does not rely on other instruments or the use of liquid nitrogen. The optical system of MIAWARA-C combines a choked gaussian horn antenna with a parabolic mirror which reduces the size of the instrument in comparison with currently existing radiometers. For the data acquisition a correlation receiver is used together with a digital cross correlating spectrometer. The complete backend section, including the computer, is located in the same housing as the instrument. The receiver section is temperature stabilized to minimize gain fluctuations. Calibration of the instrument is achieved through a balancing scheme with the sky used as the cold load and the tropospheric properties are determined by performing regular tipping curves. Since MIAWARA-C is used in measurement campaigns it is important to be able to determine the elevation pointing in a simple manner as this is a crucial parameter in the calibration process. Here we present two different methods; scanning the sky and the Sun. Finally, we report on the first spectra and retrieved water vapor profiles acquired during the Lapbiat campaign at the Finnish Meteorological Institute Arctic Research Centre in Sodankylä, Finland. The performance of MIAWARA-C is validated here by comparison of the presented profiles against the equivalent profiles from the Microwave Limb Sounder on the EOS/Aura satellite.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

TEMPERA (TEMPERature RAdiometer) is a new ground-based radiometer which measures in a frequency range from 51–57 GHz radiation emitted by the atmosphere. With this instrument it is possible to measure temperature profiles from ground to about 50 km. This is the first ground-based instrument with the capability to retrieve temperature profiles simultaneously for the troposphere and stratosphere. The measurement is done with a filterbank in combination with a digital fast Fourier transform spectrometer. A hot load and a noise diode are used as stable calibration sources. The optics consist of an off-axis parabolic mirror to collect the sky radiation. Due to the Zeeman effect on the emission lines used, the maximum height for the temperature retrieval is about 50 km. The effect is apparent in the measured spectra. The performance of TEMPERA is validated by comparison with nearby radiosonde and satellite data from the Microwave Limb Sounder on the Aura satellite. In this paper we present the design and measurement method of the instrument followed by a description of the retrieval method, together with a validation of TEMPERA data over its first year, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oral health (OH) is indivisible from general health. Several studies have established the link between morbi-mortality, especially cardiovascular, and bad OH, particularly in the case of edentation. Regrettably, part of the population choses dental care renunciation for financial reasons. The primary care physician (PCP), as the health professionnal with the most frequent and intense contacts with the patients, plays an important role to reinforce prevention measures, OH maintenance and to detect oral pathologies. To fulfill this mission, he has to be trained to endo-buccal examination. Furthermore, both the PCP and the dentist have to proactively build an interprofessional approach to promote patients' OH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Custom modes at a wavelength of 1064 nm were generated with a deformable mirror. The required surface deformations of the adaptive mirror were calculated with the Collins integral written in a matrix formalism. The appropriate size and shape of the actuators as well as the needed stroke were determined to ensure that the surface of the controllable mirror matches the phase front of the custom modes. A semipassive bimorph adaptive mirror with five concentric ring-shaped actuators and one defocus actuator was manufactured and characterised. The surface deformation was modelled with the response functions of the adaptive mirror in terms of an expansion with Zernike polynomials. In the experiments the Nd:YAG laser crystal was quasi-CW pumped to avoid thermally induced distortions of the phase front. The adaptive mirror allows to switch between a super-Gaussian mode, a doughnut mode, a Hermite-Gaussian fundamental beam, multi-mode operation or no oscillation in real time during laser operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mirror masked words are embedded into a context that makes them appear as senseless patterns or as strings of unfamiliar letters. Thus, mirror masked words can be shown for several hundreds of milliseconds without being recognised as words. We sought to further investigate effects of nonsconscious reading by monitoring event-related brain potentials (ERPs) while participants observed mirror masked letter strings. ERPs were recorded while participants observed mirror masked words and nonwords. Data of 15 participants was segmented into periods of quasi-stable field topography (microstates). Microstates for masked words and nonwords were compared using randomization tests, statistical parametric scalp maps and Low Resolution Electromagnetic Tomography (LORETA). ERPs to masked words and nonwords showed significant topographic differences between 136 and 256 ms, indicating that stimuli were nonconsciously discriminated. A LORETA model localised sources of activation discriminating between masked words and nonwords in left operculum, the right superior parietal lobe and right superior temporal gyrus indicating higher current density for nonwords than for words in these areas. ERPs of mirror masked stimuli can indicate unconscious discrimination even in cases where behavioural priming is unreliable. This approach might be useful for investigating differences in early, nonconscious stages of word perception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate unconscious priming by the use of a spatial mirror-masking paradigm. Words and nonwords with no under-length letters are mirrored at their horizontal axis. The results are figures of geometric-like forms that contain letters in their upper part. In the three experiments reported in this study, a priming procedure used such mirrored words and nonwords as primes. Participants were ignorant of the nature of the construction of the stimuli. Perceptual reports of the participants revealed that they did not realize that words were hidden in the primes. Nevertheless, they showed priming in all three experiments. Priming effects were replicated with prime–target SOAs of between 1 and 3 s. Functional dissociations were found between ignorant and informed participants. Informed groups showed perceptual and semantic priming, while ignorant groups showed only perceptual priming.