9 resultados para objective techniques
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The objective of this pilot investigation was to evaluate the utility and precision of already existing limited cone-beam computed tomography (CBCT) scans in measuring the endodontic working length, and to compare it with standard clinical procedures.
Resumo:
Reconstructions based directly upon forensic evidence alone are called primary information. Historically this consists of documentation of findings by verbal protocols, photographs and other visual means. Currently modern imaging techniques such as 3D surface scanning and radiological methods (Computer Tomography, Magnetic Resonance Imaging) are also applied. Secondary interpretation is based on facts and the examiner's experience. Usually such reconstructive expertises are given in written form, and are often enhanced by sketches. However, narrative interpretations can, especially in complex courses of action, be difficult to present and can be misunderstood. In this report we demonstrate the use of graphic reconstruction of secondary interpretation with supporting pictorial evidence, applying digital visualisation (using 'Poser') or scientific animation (using '3D Studio Max', 'Maya') and present methods of clearly distinguishing between factual documentation and examiners' interpretation based on three cases. The first case involved a pedestrian who was initially struck by a car on a motorway and was then run over by a second car. The second case involved a suicidal gunshot to the head with a rifle, in which the trigger was pushed with a rod. The third case dealt with a collision between two motorcycles. Pictorial reconstruction of the secondary interpretation of these cases has several advantages. The images enable an immediate overview, give rise to enhanced clarity, and compel the examiner to look at all details if he or she is to create a complete image.
Resumo:
Irritation of inguinal nerves with laparoscopic hernia repair may cause chronic neuralgia and hypoesthesia. Hypoesthesia in particular is generally not assessed objectively. We objectively investigated hypoesthesia and chronic pain after transabdominal preperitoneal inguinal hernia repair (TAPP) with titanium spiral tacks (STs) compared with tissue adhesive (TA) for mesh fixation.
Resumo:
PURPOSE: Two noninvasive methods to measure dental implant stability are damping capacity assessment (Periotest) and resonance frequency analysis (Osstell). The objective of the present study was to assess the correlation of these 2 techniques in clinical use. MATERIALS AND METHODS: Implant stability of 213 clinically stable loaded and unloaded 1-stage implants in 65 patients was measured in triplicate by means of resonance frequency analysis and Periotest. Descriptive statistics as well as Pearson's, Spearman's, and intraclass correlation coefficients were calculated with SPSS 11.0.2. RESULTS: The mean values were 57.66 +/- 8.19 implant stability quotient for the resonance frequency analysis and -5.08 +/- 2.02 for the Periotest. The correlation of both measuring techniques was -0.64 (Pearson) and -0.65 (Spearman). The single-measure intraclass correlation coefficients for the ISQ and Periotest values were 0.99 and 0.88, respectively (95% CI). No significant correlation of implant length with either resonance frequency analysis or Periotest could be found. However, a significant correlation of implant diameter with both techniques was found (P < .005). The correlation of both measuring systems is moderate to good. It seems that the Periotest is more susceptible to clinical measurement variables than the Osstell device. The intraclass correlation indicated lower measurement precision for the Periotest technique. Additionally, the Periotest values differed more from the normal (Gaussian) curve of distribution than the ISQs. Both measurement techniques show a significant correlation to the implant diameter. CONCLUSION: Resonance frequency analysis appeared to be the more precise technique.
Resumo:
Most recently discussion about the optimal treatment for different subsets of patients suffering from coronary artery disease has re-emerged, mainly because of the uncertainty caused by doctors and patients regarding the phenomenon of unpredictable early and late stent thrombosis. Surgical revascularization using multiple arterial bypass grafts has repeatedly proven its superiority compared to percutaneous intervention techniques, especially in patients suffering from left main stem disease and coronary 3-vessels disease. Several prospective randomized multicenter studies comparing early and mid-term results following PCI and CABG have been really restrictive, with respect to patient enrollment, with less than 5% of all patients treated during the same time period been enrolled. Coronary artery bypass grafting allows the most complete revascularization in one session, because all target coronary vessels larger than 1 mm can be bypassed in their distal segments. Once the patient has been turn-off for surgery, surgeons have to consider the most complete arterial revascularization in order to decrease the long-term necessity for re-revascularization; for instance patency rate of the left internal thoracic artery grafted to the distal part left anterior descending artery may be as high as 90-95% after 10 to 15 years. Early mortality following isolated CABG operation has been as low as 0.6 to 1% in the most recent period (reports from the University Hospital Berne and the University Hospital of Zurich); beside these excellent results, the CABG option seems to be less expensive than PCI with time, since the necessity for additional PCI is rather high following initial PCI, and the price of stent devices is still very high, particularly in Switzerland. Patients, insurance and experts in health care should be better and more honestly informed concerning the risk and costs of PCI and CABG procedures as well as about the much higher rate of subsequent interventions following PCI. Team approach for all patients in whom both options could be offered seems mandatory to avoid unbalanced information of the patients. Looking at the recent developments in transcatheter valve treatments, the revival of cardiological-cardiosurgical conferences seems to a good option to optimize the cooperation between the two medical specialties: cardiology and cardiac surgery.
Resumo:
BACKGROUND: Harvesting techniques can affect cellular parameters of autogenous bone grafts in vitro. Whether these differences translate to in vivo bone formation, however, remains unknown. OBJECTIVE: The purpose of this study was to assess the impact of different harvesting techniques on bone formation and graft resorption in vivo. MATERIAL AND METHODS: Four harvesting techniques were used: (i) corticocancellous blocks particulated by a bone mill; (ii) bone scraper; (iii) piezosurgery; and (iv) bone slurry collected from a filter device upon drilling. The grafts were placed into bone defects in the mandibles of 12 minipigs. The animals were sacrificed after 1, 2, 4 and 8 weeks of healing. Histology and histomorphometrical analyses were performed to assess bone formation and graft resorption. An explorative statistical analysis was performed. RESULTS: The amount of new bone increased, while the amount of residual bone decreased over time with all harvesting techniques. At all given time points, no significant advantage of any harvesting technique on bone formation was observed. The harvesting technique, however, affected bone formation and the amount of residual graft within the overall healing period. Friedman test revealed an impact of the harvesting technique on residual bone graft after 2 and 4 weeks. At the later time point, post hoc testing showed more newly formed bone in association with bone graft processed by bone mill than harvested by bone scraper and piezosurgery. CONCLUSIONS: Transplantation of autogenous bone particles harvested with four techniques in the present model resulted in moderate differences in terms of bone formation and graft resorption.
Resumo:
REASONS FOR PERFORMING STUDY: There is limited information on potential diffusion of local anaesthetic solution after various diagnostic analgesic techniques of the proximal metacarpal region. OBJECTIVE: To document potential distribution of local anaesthetic solution following 4 techniques used for diagnostic analgesia of the proximal metacarpal region. METHODS: Radiodense contrast medium was injected around the lateral palmar or medial and lateral palmar metacarpal nerves in 8 mature horses, using 4 different techniques. Radiographs were obtained 0, 10 and 20 min after injection and were analysed subjectively. A mixture of radiodense contrast medium and methylene blue was injected into 4 cadaver limbs; the location of the contrast medium and dye was determined by radiography and dissection. RESULTS: Following perineural injection of the palmar metacarpal nerves, most of the contrast medium was distributed in an elongated pattern axial to the second and fourth metacarpal bones. The carpometacarpal joint was inadvertently penetrated in 4/8 limbs after injections of the palmar metacarpal nerves from medial and lateral approaches, and in 1/8 limbs when both injections were performed from the lateral approach. Following perineural injection of the lateral palmar nerve using a lateral approach, the contrast medium was diffusely distributed in all but one limb, in which the carpal sheath was inadvertently penetrated. In 5/8 limbs, following perineural injection of the lateral palmar nerve using a medial approach, the contrast medium diffused proximally to the distal third of the antebrachium. CONCLUSIONS AND POTENTIAL RELEVANCE: Inadvertent penetration of the carpometacarpal joint is common after perineural injection of the palmar metacarpal nerves, but less so if both palmar metacarpal nerves are injected using a lateral approach. Following injection of the lateral palmar nerve using a medial approach, the entire palmar aspect of the carpus may be desensitised.
Resumo:
BACKGROUND Since the pioneering work of Jacobson and Suarez, microsurgery has steadily progressed and is now used in all surgical specialities, particularly in plastic surgery. Before performing clinical procedures it is necessary to learn the basic techniques in the laboratory. OBJECTIVE To assess an animal model, thereby circumventing the following issues: ethical rules, cost, anesthesia and training time. METHODS Between July 2012 and September 2012, 182 earthworms were used for 150 microsurgical trainings to simulate discrepancy microanastomoses. Training was undertaken over 10 weekly periods. Each training session included 15 simulations of microanastomoses performed using the Harashina technique (earthworm diameters >1.5 mm [n=5], between 1.0 mm and 1.5 mm [n=5], and <1.0 mm [n=5]). The technique is presented and documented. A linear model with main variable as the number of the week (as a numeric covariate) and the size of the animal (as a factor) was used to determine the trend in time of anastomosis over subsequent weeks as well as differences between the different size groups. RESULTS The linear model showed a significant trend (P<0.001) in time of anastomosis in the course of the training, as well as significant differences (P<0.001) between the groups of animal of different sizes. For diameter >1.5 mm, mean anastomosis time decreased from 19.6±1.9 min to 12.6±0.7 min between the first and last week of training. For training involving smaller diameters, the results showed a reduction in execution time of 36.1% (P<0.01) (diameter between 1.0 mm and 1.5 mm) and 40.6% (P<0.01) (diameter <1.0 mm) between the first and last weeks. The study demonstrates an improvement in the dexterity and speed of nodes' execution. CONCLUSION The earthworm appears to be a reliable experimental model for microsurgical training of discrepancy microanastomoses. Its numerous advantages, as discussed in the present report, show that this model of training will significantly grow and develop in the near future.
Resumo:
UNLABELLED OBJECTIVE; Virtual autopsy methods, such as postmortem CT and MRI, are increasingly being used in forensic medicine. Forensic investigators with little to no training in diagnostic radiology and medical laypeople such as state's attorneys often find it difficult to understand the anatomic orientation of axial postmortem CT images. We present a computer-assisted system that permits postmortem CT datasets to be quickly and intuitively resliced in real time at the body to narrow the gap between radiologic imaging and autopsy. CONCLUSION Our system is a potentially valuable tool for planning autopsies, showing findings to medical laypeople, and teaching CT anatomy, thus further closing the gap between radiology and forensic pathology.