7 resultados para model base

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a geospatial model to predict the radiofrequency electromagnetic field from fixed site transmitters for use in epidemiological exposure assessment. The proposed model extends an existing model toward the prediction of indoor exposure, that is, at the homes of potential study participants. The model is based on accurate operation parameters of all stationary transmitters of mobile communication base stations, and radio broadcast and television transmitters for an extended urban and suburban region in the Basel area (Switzerland). The model was evaluated by calculating Spearman rank correlations and weighted Cohen's kappa (kappa) statistics between the model predictions and measurements obtained at street level, in the homes of volunteers, and in front of the windows of these homes. The correlation coefficients of the numerical predictions with street level measurements were 0.64, with indoor measurements 0.66, and with window measurements 0.67. The kappa coefficients were 0.48 (95%-confidence interval: 0.35-0.61) for street level measurements, 0.44 (95%-CI: 0.32-0.57) for indoor measurements, and 0.53 (95%-CI: 0.42-0.65) for window measurements. Although the modeling of shielding effects by walls and roofs requires considerable simplifications of a complex environment, we found a comparable accuracy of the model for indoor and outdoor points.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Awake hamsters equipped with the dorsal window chamber preparation were subjected to hemorrhage of 50% of the estimated blood volume. Initial resuscitation (25% of estimated blood volume) with polymerized bovine hemoglobin (PBH) or 10% hydroxyethyl starch (HES) occurred in concert with an equivolumetric bleeding to simulate the early, prehospital setting (exchange transfusion). Resuscitation (25% of estimated blood volume) without bleeding was performed with PBH, HES, or autologous red blood cells (HES-RBCs). Peripheral microcirculation, tissue oxygenation, and systemic hemodynamic and blood gas parameters were assessed. After exchange transfusion, base deficit was -8.6 +/- 3.7 mmol/L (PBH) and -5.1 +/- 5.3 mmol/L (HES) (not significant). Functional capillary density was 17% +/- 6% of baseline (PBH) and 31% +/- 11% (HES) (P < 0.05) and arteriolar diameter 73% +/- 3% of baseline (PBH) and 90% + 5% (HES) (P < 0.01). At the end, hemoglobin levels were 3.7 +/- 0.3 g/dL with HES, 8.2 +/- 0.6 g/dL with PBH, and 10.4 +/- 0.8 g/dL with HES-RBCs (P < 0.01 HES vs. PBH and HES-RBCs, P < 0.05 PBH vs. HES-RBCs). Base excess was restored to baseline with PBH and HES-RBCs, but not with HES (P < 0.05). Functional capillary density was 46% +/- 5% of baseline (PBH), 62% + 20% (HES-RBCs), and 36% +/- 19% (HES) (P < 0.01 HES-RBCs vs. HES). Peripheral oxygen delivery and consumption was highest with HES-RBCs, followed by PBH (P < 0.05 HES-RBCs vs. PBH, P < 0.01 HES-RBCs and PBH vs. HES). In conclusion, the PBH led to a correction of base deficit comparable to blood transfusion. However, oxygenation of the peripheral tissue was inferior with PBH. This was attributed to its negative impact on the peripheral microcirculation caused by arteriolar vasoconstriction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to analyze the suitability of the cerebral vasculature of the pig regarding a revascularization procedure. In two 60 kg pigs the femoral artery was exposed and canulated for selective angiography and interventional procedures. After the angiography, the pigs were brought to the animal OR for craniotomy and analysis of the intracranial cerebral arteries and the surgical exposure of the carotid arteries under the microscope. Angiography demonstrated the presence of a true internal-, external carotid artery and vertebral arteries. Both the vertebral and internal carotid arteries are feeding a rete mirabilis both at the cranial base and the cranio-cervical junction. At these sites further advancement of the angiography catheter was not possible. Out of these rete mirabilis, an intracranial carotid artery and an intracranial vertebral artery were formed, respectively. The intracranial cerebral vessels were of the dimension of 1 mm and less. The extracranial portion of the internal carotid artery was 2.5 mm of diameter. From these findings, we conclude that a direct cerebral revascularization procedure of the intracranial vessels is not possible in the swine. However, a global revascularization procedure on the extracranial portion of the internal carotid artery is thus feasible, both using a low- and high-flow anastamosis technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radio frequency electromagnetic fields (RF-EMF) in our daily life are caused by numerous sources such as fixed site transmitters (e.g. mobile phone base stations) or indoor devices (e.g. cordless phones). The objective of this study was to develop a prediction model which can be used to predict mean RF-EMF exposure from different sources for a large study population in epidemiological research. We collected personal RF-EMF exposure measurements of 166 volunteers from Basel, Switzerland, by means of portable exposure meters, which were carried during one week. For a validation study we repeated exposure measurements of 31 study participants 21 weeks after the measurements of the first week on average. These second measurements were not used for the model development. We used two data sources as exposure predictors: 1) a questionnaire on potentially exposure relevant characteristics and behaviors and 2) modeled RF-EMF from fixed site transmitters (mobile phone base stations, broadcast transmitters) at the participants' place of residence using a geospatial propagation model. Relevant exposure predictors, which were identified by means of multiple regression analysis, were the modeled RF-EMF at the participants' home from the propagation model, housing characteristics, ownership of communication devices (wireless LAN, mobile and cordless phones) and behavioral aspects such as amount of time spent in public transports. The proportion of variance explained (R2) by the final model was 0.52. The analysis of the agreement between calculated and measured RF-EMF showed a sensitivity of 0.56 and a specificity of 0.95 (cut-off: 90th percentile). In the validation study, the sensitivity and specificity of the model were 0.67 and 0.96, respectively. We could demonstrate that it is feasible to model personal RF-EMF exposure. Most importantly, our validation study suggests that the model can be used to assess average exposure over several months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In conventional software applications, synchronization code is typically interspersed with functional code, thereby impacting understandability and maintainability of the code base. At the same time, the synchronization defined statically in the code is not capable of adapting to different runtime situations. We propose a new approach to concurrency control which strictly separates the functional code from the synchronization requirements to be used and which adapts objects to be synchronized dynamically to their environment. First-class synchronization specifications express safety requirements, and a dynamic synchronization system dynamically adapts objects to different runtime situations. We present an overview of a prototype of our approach together with several classical concurrency problems, and we discuss open issues for further research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fractures of the keel bone, a bone extending ventrally from the sternum, are a serious health and welfare problem in free range laying hens. Recent findings suggest that a major cause of keel damage within extensive systems is collisions with internal housing structures, though investigative efforts have been hindered by difficulties in examining mechanisms and likely influencing factors at the moment of fracture. The objectives of this study were to develop an ex vivo impact protocol to model bone fracture in hens caused by collision, to assess impact and bird-related factors influencing fracture occurrence and severity, and to identify correlations of mechanical and structural properties between different skeletal sites. We induced keel bone fractures in euthanized hens using a drop-weight impact tester able to generate a range of impact energies, producing fractures that replicate those commonly found in commercial settings. The results demonstrated that impact energies of a similar order to those expected in normal housing were able to produce fractures, and that greater collision energies resulted in an increased likelihood of fractures and of greater severity. Relationships were also seen with keel's lateral surface bone mineral density, and the peak reactive force (strength) at the base of the manubrial spine. Correlations were also identified between the keel and long bones with respect to both strength and bone mineral density. This is the first study able to relate impact and bone characteristics with keel bone fracture at the moment of collision. Greater understanding of these relationships will provide means to reduce levels of breakage and severity in commercial systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Currently one of the most widely used models for the development of endovascular techniques and coiling devices for treatment of aneurysm is the elastase-induced aneurysm model in the rabbit carotid artery. Microsurgical techniques for creating an aneurysm with a venous pouch have also been established, although both techniques usually result in aneurysms less than 1 cm in diameter. We investigated whether an increase in blood flow toward the neck would produce larger aneurysms in a microsurgical venous pouch model. MATERIALS AND METHODS Microsurgical operations were performed on 11 New Zealand white rabbits. Both carotid arteries and the right jugular vein were dissected, and the right carotid artery was temporarily clipped followed by an arteriotomy. The left carotid artery was also clipped proximally, ligated distally, and sutured onto the proximal half of the arteriotomy in the right carotid artery. The venous graft was sutured onto the distal half of the arteriotomy. Digital subtraction angiography was also performed. RESULTS Angiography showed patent anastomosed vessels and aneurysms in the seven surviving rabbits. Mean aneurysm measurements among surviving rabbits with patent vessels were: 13.9 mm length, 9.3 mm width, and neck diameter 4.7 mm. The resulting mean aspect ratio was 3.35 and the mean bottleneck ratio was 3.05. CONCLUSION A large venous graft and increased blood flow toward the base of the aneurysm seem to be key factors in the creation of large venous pouch aneurysms. These large aneurysms allow testing of endovascular devices designed for large and giant aneurysms.