192 resultados para minimally invasive methods
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Microneurography is a method suitable for recording intraneural single or multiunit action potentials in conscious subjects. Microneurography has rarely been applied to animal experiments, where more invasive methods, like the teased fiber recording technique, are widely used. We have tested the feasibility of microneurographic recordings from the peripheral nerves of rats. Tungsten microelectrodes were inserted into the sciatic nerve at mid-thigh level. Single or multiunit action potentials evoked by regular electrical stimulation were recorded, digitized and displayed as a raster plot of latencies. The method allows unambiguous recording and recognition of single C-fiber action potentials from an in vivo preparation, with minimal disruption of the nerve being recorded. Multiple C-fibers can be recorded simultaneously for several hours, and if the animal is allowed to recover, repeated recording sessions can be obtained from the same nerve at the same level over a period of weeks or months. Also, single C units can be functionally identified by their changes in latency to natural stimuli, and insensitive units can be recognized as 'silent' nociceptors or sympathetic efferents by their distinctive profiles of activity-dependent slowing during repetitive electrical stimulation, or by the effect on spontaneous efferent activity of a proximal anesthetic block. Moreover, information about the biophysical properties of C axons can be obtained from their latency recovery cycles. Finally, we show that this preparation is potentially suitable for the study of C-fiber behavior in models of neuropathies and nerve lesions, both under resting conditions and in response to drug administration.
Resumo:
We investigated the feasibility of postmortem percutaneous needle biopsy (PNB) for obtaining pulmonary samples adequate for the study of pulmonary fat embolism (PFE). Samples of both lungs were obtained from 26 cadavers via two different methods: (i) PNB and (ii) the double-edged knife technique, the gold standard at our institute. After water storage and Sudan III staining, six forensic pathologists independently examined all samples for the presence and severity of PFE. The results were compared and analyzed in each case regarding the vitality of the PFE and its relationship to the cause of death. The results showed that PFE was almost identically diagnosed and graded on the samples obtained via both methods. The discrepancies between the two techniques did not affect the diagnoses of vitality or cause of death related to PFE. This study demonstrates the feasibility of the PNB sampling method for the diagnosis and interpretation of PFE in the postmortem setting.
Resumo:
For the past 10 years, medical imaging techniques have been increasingly applied to forensic investigations. To obtain histological and toxicological information, tissue and liquid samples are required. In this article, we describe the development of a low-cost, secure, and reliable approach for a telematic add-on for remotely planning biopsies on the Virtobot robotic system. Data sets are encrypted and submitted over the Internet. A plugin for the OsiriX medical image viewer allows for remote planning of needle trajectories that are used for needle placement. The application of teleradiological methods to image-guided biopsy in the forensic setting has the potential to reduce costs and, in conjunction with a mobile computer tomographic scanner, allows for tissue sampling in a mass casualty situation involving nuclear, biological, or chemical agents, in a manner that minimizes the risk to involved staff.
Resumo:
Conclusion: A robot built specifically for stereotactic cochlear implantation provides equal or better accuracy levels together with a better integration into a clinical environment, when compared to existing approaches based on industrial robots. Objectives: To evaluate the technical accuracy of a robotic system developed specifically for lateral skull base surgery in an experimental setup reflecting the intended clinical application. The invasiveness of cochlear electrode implantation procedures may be reduced by replacing the traditional mastoidectomy with a small tunnel slightly larger in diameter than the electrode itself. Methods: The end-to-end accuracy of the robot system and associated image-guided procedure was evaluated on 15 temporal bones of whole head cadaver specimens. The main components of the procedure were as follows: reference screw placement, cone beam CT scan, computer-aided planning, pair-point matching of the surgical plan, robotic drilling of the direct access tunnel, and post-operative cone beam CT scan and accuracy assessment. Results: The mean accuracy at the target point (round window) was 0.56 ± 41 mm with an angular misalignment of 0.88 ± 0.41°. The procedural time of the registration process through the completion of the drilling procedure was 25 ± 11 min. The robot was fully operational in a clinical environment.
Resumo:
BACKGROUND: In a prospective, nonrandomized study the outcome in terms of rehabilitation and complications of total hip arthroplasty (THA) through a superior capsulotomy exposure (study group) was compared to THA performed through a direct lateral exposure (control group). PATIENTS AND METHODS: The study group (106 THA) and the control group (107 THA) were controlled for complexity and had no significant differences in age, sex, diagnosis, or body mass index. RESULTS: The study group had improved recovery at 6 weeks after surgery which was statistically significant (p<0.001). In addition, the study group had a lower incidence of perioperative complications. CONCLUSION: The current study demonstrates the potential that less-invasive surgical techniques with the philosophy of maximally preserving the abductors, posterior capsule, and short rotators may result in a safer operation with an accelerated recovery.
Resumo:
Three different fissure preparation procedures were tested and compared to the non-invasive approach using a conventional unfilled sealant and a flowable composite. Eighty permanent molars were selected and divided into 4 groups of 20 teeth each. All the teeth were split into 2 halves, and the exposed fissures were photographed under a microscope (35x) before and after being prepared using the following methods: (I) Er:YAG laser (KEY Laser, KaVo) 600 mJ pulse energy, 6 Hz; (II) diamond bur; (III) Er: YAG laser (KEY Laser, KaVo) 200 mJ pulse energy, 4 Hz; (IV) Control group: Powder jet cleaner (Prophyflex, KaVo, Germany). The pre-and postimages were superimposed in order to evaluate the amount of hard tissue removed. Ten teeth in each group were then acid etched and sealed with an unfilled sealant (Delton opaque, Dentsply), while the remaining 10 teeth were acid etched, primed and bonded (Prime ; Bond NT, Dentsply) and sealed with a flowable composite (X-flow, DeTrey, Dentsply). Material penetration and microleakage were evaluated after thermocycling (5000 cycles) and staining with methylene blue 5%. ANOVA and Mann-Whitney tests were applied for statistical analysis. The laser 600 mJ and bur eliminated the greatest amount of hard tissue. The control teeth presented the least microleakage when sealed with Delton or X-flow. A correlation between material penetration and microleakage could not be statistically confirmed. Mechanical preparation prior to fissure sealing did not enhance the final performance of the sealant.
Resumo:
OBJECTIVES: The aim of the here described case series was to develop and evaluate the minimally invasive percutaneous osteosynthesis for the plate fixation of tibial fractures in dogs and cats. METHODS: Six dogs and four cats with shaft fractures of the tibia were treated using minimally invasive percutaneous osteosynthesis. Follow-up radiographs four to six weeks after fracture fixation were evaluated for fracture healing. For the long-term follow-up (minimum 2.4 years), owners were contacted by phone to complete a questionnaire. RESULTS: All fractures healed without the need for a second procedure. Follow-up radiographs obtained after four to six weeks in seven cases showed advanced bony healing with callus formation and filling of the fracture gaps with calcified tissue in all seven. All the patients had a good to excellent long-term result with full limb function. The time needed for regaining full limb use was two to three months. CLINICAL SIGNIFICANCE: Minimally invasive percutaneous osteosynthesis seems to be a useful technique for the treatment of tibial shaft fractures in dogs and cats.
Resumo:
PURPOSE: To present a novel, minimally invasive strabismus surgery (MISS) technique for inferior obliquus recessions. METHODS: Graded MISS inferior obliquus recessions were performed in 20 eyes of 15 patients by applying two small conjunctival cuts, one at the insertion of inferior obliquus and another where the scleral anchoring of the muscle occurred. RESULTS: The amount of recession was 12.2 +/- 2.3 mm (range 6 to 14 mm). The vertical deviation, which was measured in 25 degrees of adduction, decreased from preoperatively 12.8 degrees +/- 5.6 degrees to 2.7 degrees +/- 2.2 degrees (p < 0.0001) at 6 months. LogMAR visual acuity was preoperatively -0.10 +/- 0.17 and at 6 months -0.14 +/- 0.22 (p > 0.1). In one eye (2.5%) the two cuts had to be joined because of excessive bleeding. Binocular vision improved in eight patients, remained unchanged in six patients, and decreased from 30 to 60 arcsec in one patient (p > 0.1). Conjunctival and lid swelling were hardly visible on the first postoperative day in primary gaze position in 10/20 (50%) of eyes. Five of the eyes (25%) had mild and five (25%) moderate visibility of surgery. One patient out of 15 (7%) needed repeat surgery because of insufficient reduction of the sursoadduction within the first 6 months. The dose-effect relationship 6 months postoperatively for an accommodative near target at 25 degrees adduction was 0.83 degrees +/- 0.43 degrees per mm of recession. CONCLUSIONS: This study demonstrates that small-incision, minimal dissection inferior obliquus graded recessions are feasible and effective to improve ocular alignment in patients with strabismus sursoadductorius.
Resumo:
AIMS: To present a novel, minimally invasive strabismus surgery (MISS) technique for rectus muscle posterior fixation. METHODS: This study reports the results of 32 consecutive MISS rectus muscle posterior fixation surgeries performed on 19 patients by applying only two small L-shaped openings where the two retroequatorial scleromuscular sutures were placed. RESULTS: On the first postoperative day, in primary position, redness was hardly visible in 16 eyes (50%) and only moderate redness was visible in 6 eyes (19%). No serious complication occurred. Preoperative visual acuity and refraction remained unchanged at 6 months (p > 0.1). The preoperative convergence excess (n = 13) decreased from 10.3 +/- 4.1 to 5.2 +/- 4.0 degrees at 6 months (p < 0.005). In all patients operated on for gaze incomitance (n = 6) improvement was achieved at 6 months. CONCLUSIONS: This study shows that keyhole minimal-dissection rectus muscle posterior fixation surgery is feasible and effective to improve ocular alignment. The MISS technique seems to be superior in the direct postoperative period since only minimal conjunctival swelling and no corneal complications were observed.
Resumo:
AIMS: To study if minimally invasive strabismus surgery (MISS) is suitable for rectus muscle reoperations. METHODS: The study presents a series of consecutive patients operated on by the same surgeon at Kantonsspital St Gallen, Switzerland with a novel MISS rectus muscle reoperation technique. Surgery is done by applying two small radial cuts along the muscle insertion. Through the tunnel obtained after muscle separation from surrounding tissue, a recession, advancement or plication is performed. RESULTS: In 62 eyes of 51 patients (age 35.4 (SD 16.3) years) a total of 86 horizontal rectus muscles were reoperated. On the average, the patients had 2.1 strabismus surgeries previously. Preoperative logMAR visual acuity was 0.38 (0.82) compared with 0.37 (0.83) at 6 months (p>0.1). On the first postoperative day, in the primary gaze position conjunctival and lid swelling and redness was hardly visible in 11 eyes, discrete in 15 eyes, moderate in 11 eyes and severe in 15 eyes. One corneal dellen and one corneal erosion occurred, which both quickly resolved. The preoperative deviation at distance for esodeviations (n = 15) of 12.5 (8.5) degrees decreased to 2.6 (7.8) degrees at 6 months (p<0.001). For near, a decrease from 12.0 (10.1) degrees to 2.9 (1.6) degrees was observed (p<0.001). The preoperative deviation at distance for exodeviations (n = 35) of -16.4 (8.5) degrees decreased to -7.9 (6.5) degrees at 6 months (p<0.005). For near, a decrease from -16.5 (11.4) degrees to -2.9 (1.5) degrees was observed (p<0.005). Within the first 6 months, only one patient had a reoperation. At month 6, in four patients a reoperation was planned or suggested by us because of unsatisfactory alignment. No patient experienced persistent diplopia or necessitated a reoperation because of double vision. Stereovision improved at month 6 compared with preoperatively (p<0.01). CONCLUSIONS: The study demonstrates that a small-cut, minimal dissection technique allows to perform rectus muscle reoperations. The MISS technique seems to reduce conjunctival and lid swelling in the direct postoperative period.
Resumo:
AIM: To present a novel, minimally invasive strabismus surgery (MISS) technique for rectus muscle operations. METHODS: In this prospective study with a non-concurrent, retrospective comparison group, the first 20 consecutive patients treated with MISS were matched by age, diagnosis and muscles operated on, with 20 patients with a limbal opening operated on by the same surgeon at Kantonsspital, St Gallen, Switzerland. A total of 39 muscles were operated on. MISS is performed by applying two small radial cuts along the superior and inferior muscle margin. After muscle separation from surrounding tissue, a recession or plication is performed through the resulting tunnel. Alignment, binocular single vision, variations in vision, refraction, and number and types of complications during the first 6 postoperative months were registered. RESULTS: Visual acuity decreased at postoperative day 1 in both groups. The decrease was less pronounced in the group operated on with MISS (difference of decrease 0.14 logMAR, p<0.001). An abnormal lid swelling at day 1 was more frequent in the control group (21%, 95% confidence interval (CI) 9% to 41%, 5/24 v 0%, 95% CI 0 to 13%, 0/25, p<0.05). No significant difference was found for final alignment, binocular single vision, other visual acuities, refractive changes or complications (allergic reactions, dellen formation, abnormal conjuctival findings). A conversion to a limbal opening was necessary in 5% (95% CI 2% to 17%, 2/39) of muscles. CONCLUSIONS: This study shows that this new, small-incision, minimal dissection technique is feasible. The MISS technique seems to be superior in the direct postoperative period as better visual acuities and less lid swelling were observed. Long-term results did not differ in the two groups.
Resumo:
PURPOSE: To evaluate the efficacy of superselective embolization therapy in the management of acute lower gastrointestinal (LGI) hemorrhage, including any bleeding distal to the ligament of Treitz. MATERIALS AND METHODS: Between June and August 2007, 20 patients with acute LGI bleeding underwent superselective transcatheter arterial embolization (TAE) at the authors' institution. The bleeding had different causes. All patients were treated with use of microcatheters. The following embolic agents were used: microcoils (n = 16), polyvinyl alcohol (PVA) particles (n = 2), and a combination of microcoils and PVA particles (n = 2). Outcome measures included technical success (complete cessation of bleeding as documented at completion angiography), clinical success (resolution of signs or symptoms of LGI bleeding within 30 days after TAE), and the rate of major and minor complications. RESULTS: The identified bleeding sources were as follows: jejunal branch, branch of middle colic artery, branch of ileocolic artery, ileal branch, branch of left colic artery, branch of sigmoid artery, branch of the superior rectal artery, and branch of the middle rectal artery. Technical success with effective control of active bleeding was achieved in all patients (100%). Clinical success attributed to TAE was documented in 18 of the 20 patients (90%). Major complications included death due to pulmonary embolism, heart infarction, and multiorgan failure in the 3rd week after TAE; a procedure-related colonic infarction occurred in one patient. A minor complication occurred in one patient who developed a groin hematoma. CONCLUSIONS: Superselective embolization may be used for effective, minimally invasive control of acute LGI bleeding.
Resumo:
What's known on the subject? and What does the study add? The EndoSew® prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew® suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew®. The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. Objective To evaluate the feasibility and safety of the novel prototype sewing device EndoSew® in placing an extracorporeal resorbable running suture for ileal conduits. Patients and Methods We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew® running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew® only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. Results A complete EndoSew® running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew® suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3–10) min and the median (range) suture length was 4.5 (2–5.5) cm. There were no suture-related complications. Conclusions The EndoSew® procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew® has the potential to facilitate the intracorporeal construction of urinary diversions.
Resumo:
OBJECTIVE: To test a new tiny-tipped intraoperative diagnostic tool that was designed to provide the surgeon with reliable stiffness data on the motion segment during microdiscectomy. A decrease in stiffness after nuclectomy and a measurable influence of muscle tension were assumed. If the influence of muscle tension on the motion segment could at least be ruled out, there should be no difference with regard to stiffness between women and men. If these criteria are met, this new intraoperative diagnostic tool could be used in further studies for objective decision-making regarding additional stabilization systems after microdiscectomy. METHODS: After evaluation of the influence of muscle relaxation during in vivo measurements with a spinal spreader between the spinous processes, 21 motion segments were investigated in 21 patients. Using a standardized protocol, including quantified muscle relaxation, spinal stiffness was measured before laminotomy and after nuclectomy. RESULTS: The decrease in stiffness after microdiscectomy was highly significant. There were no statistically significant differences between men and women. The average stiffness value before discectomy was 33.7 N/mm, and it decreased to 25.6 N/mm after discectomy. The average decrease in stiffness was 8.1 N/mm (24%). CONCLUSION: In the moderately degenerated spine, stiffness decreases significantly after microdiscectomy. Control for muscle relaxation is essential when measuring in vivo spinal stiffness. The new spinal spreader was found to provide reliable data. This spreader could be used in further studies for objective decision-making about additional stabilization systems after microdiscectomy.
Resumo:
Objectives: To investigate substance loss and bond strength capacity of sclerotic, non-carious cervical dentin after airborne-particle abrasion or diamond bur preparation. Methods: Fifteen non-sclerotic dentin specimens were made from crowns of extracted human incisors of which the labial surfaces had been ground with silicon carbide papers (non-sclerotic control; Group 1). Forty-five sclerotic dentin specimens (n=15/group) were made from the labial, non-carious cervical root part of extracted human incisors and underwent either no pre-treatment (sclerotic control; Group 2), pre-treatment with airborne-particle abrasion (CoJet Prep [3M ESPE] and 50 µm aluminium oxide; Group 3), or with diamond bur preparation (40 µm grit size; Group 4). Substance loss after pre-treatment was measured in Groups 3 and 4. Subsequently, Scotchbond Universal (3M ESPE) and resin composite (CeramX [DENTSPLY DeTrey]) were applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by Wilcoxon rank sum tests. Results: Substance loss (medians) was 19 µm in Group 3 and 113 µm in Group 4. SBS-values (MPa; medians) in Group 2 (9.24) were significantly lower than in Group 1 (13.15; p=0.0069), Group 3 (13.05; p=0.01), and Group 4 (13.02; p=0.0142). There were no significant differences in SBS between Groups 1, 3, and 4 (p≥0.8063). Conclusion: Airborne-particle abrasion and diamond bur preparation restored bond strength of Scotchbond Universal to sclerotic dentin to the level of non-sclerotic dentin, with airborne-particle abrasion being less invasive than diamond bur preparation.