28 resultados para middle ear

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thiel-embalmed human whole head specimens represent an alternative model in middle ear research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To generate anatomical data on the human middle ear and adjacent structures to serve as a base for the development and optimization of new implantable hearing aid transducers. Implantable middle ear hearing aid transducers, i.e. the equivalent to the loudspeaker in conventional hearing aids, should ideally fit into the majority of adult middle ears and should utilize the limited space optimally to achieve sufficiently high maximal output levels. For several designs, more anatomical data are needed. METHODS: Twenty temporal bones of 10 formalin-fixed adult human heads were scanned by a computed tomography system (CT) using a slide thickness of 0.63 mm. Twelve landmarks were defined and 24 different distances were calculated for each temporal bone. RESULTS: A statistical description of 24 distances in the adult human middle ear which may limit or influence the design of middle ear transducers is presented. Significant inter-individual differences but no significant differences for gender, side, age or degree of pneumatization of the mastoid were found. Distances, which were not analyzed for the first time in this study, were found to be in good agreement with the results of earlier studies. CONCLUSION: A data set describing the adult human middle ear anatomy quantitatively from the point of view of designers of new implantable hearing aid transducers has been generated. In principle, the method employed in this study using standard CT scans could also be used preoperatively to rule out exclusion criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A life-size mechanical middle ear model and human temporal bones were used to evaluate three different middle ear transducers for implantable hearing aids: the driving rod transducer (DRT), the floating mass transducer (FMT) or vibrant sound bridge, and the contactless transducer (CLT). Results of the experiments with the mechanical model were within the range of the results for human temporal bones. However, results with the mechanical model showed better reproducibility. The handling of the mechanical model was considerably simpler and less time-consuming. Systematic variations of mounting parameters showed that the angle of the rod has virtually no effect on the output of the DRT, the mass loading on the cable of the FMT has a larger impact on the output than does the tightness of crimping, and the output level of the CLT can be increased by 10 dB by optimizing the mounting parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a case of a 28-year-old male with a seizure episode and a 4-year history of intermittent tinnitus on the left ear. On computed tomography and magnetic resonance imaging, a density with rim enhancement was found at the temporal lobe, associated with mastoid tegmen destruction and middle ear mass, indicating cholesteatoma with complicating brain abscess. Evacuation of the brain abscess was performed with a combined otolaryngologic and neurosurgical procedures (canal wall-down mastoidectomy and temporal craniotomy). The pathology turned out to be infestation with Echinococcus granulosus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thiel-embalmed human whole-head specimens offer a promising alternative model for bone conduction (BC) studies of middle ear structures. In this work we present the Thiel model’s linearity and stability over time as well as its possible use in the study of a fixed ossicle chain. Using laser Doppler vibrometry (LDV), the motion of the retroauricular skull, the promontory, the stapes footplate and the round window (RW) were measured. A bone-anchored hearing aid stimulated the ears with step sinus tones logarithmically spread between 0.1 and 10 kHz. Linearity of the model was verified using input levels in steps of 10 dBV. The stability of the Thiel model over time was examined with measurements repeated after hours and weeks. The influence of a cement-fixed stapes was assessed. The middle ear elements measured responded linearly in amplitude for the applied input levels (100, 32.6, and 10 mV). The variability of measurements for both short- (2 h) and long-term (4-16 weeks) repetitions in the same ear was lower than the interindividual difference. The fixation of the stapes induced a lowered RW displacement for frequencies near 750 Hz (-4 dB) and an increased displacement for frequencies above 1 kHz (max. +3.7 dB at 4 kHz). LDV assessment of BC-induced middle ear motion in Thiel heads can be performed with stable results. The vibratory RW response is affected by the fixation of the stapes, indicating a measurable effect of ossicle chain inertia on BC response in Thiel embalmed heads.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new hearing therapy based on direct acoustic cochlear stimulation was developed for the treatment of severe to profound mixed hearing loss. The device efficacy was validated in an initial clinical trial with four patients. This semi-implantable investigational device consists of an externally worn audio processor, a percutaneous connector, and an implantable microactuator. The actuator is placed in the mastoid bone, right behind the external auditory canal. It generates vibrations that are directly coupled to the inner ear fluids and that, therefore, bypass the external and the middle ear. The system is able to provide an equivalent sound pressure level of 125 dB over the frequency range between 125 and 8000 Hz. The hermetically sealed actuator is designed to provide maximal output power by keeping its dimensions small enough to enable implantation. A network model is used to simulate the dynamic characteristics of the actuator to adjust its transfer function to the characteristics of the middle ear. The geometry of the different actuator components is optimized using finite-element modeling.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although non-organic hearing losses are relatively rare, it is important to identify suspicious findings early to be able to administer specific tests, such as objective measurements and specific counseling. In this retrospective study, we searched for findings that were specific ti or typical for non-organic hearing losses. Patient records from a 6 year period (2003-2008) from the University ENT Department of Bern, Switzerland, were reviewed. In this period, 40 subjects were diagnosed with a non-organic hearing loss (22 children, ages 7-16, mean 10.6 years; 18 adults, ages 19-57, mean 39.7 years; 25 females and 15 males). Pure tone audiograms in children and adults showed predominantly sensorineural and frequency-independent hearing losses, mostly in the range of 40-60 dB. In all cases, objective measurements (otoacoustic emissions and/or auditory-evoked potentials) indicated normal or substantially better hearing thresholds than those found in pure tone audiometry. In nine subjects (22.5%; 2 children, 7 adults), hearing aids had been fitted before the first presentation at our center. Six children (27%) had a history of middle ear problems with a transient hearing loss and 11 (50%) knew a person with a hearing loss. Two new and hitherto unreported findings emerged from the analysis: it was observed that a small air-bone gap of 5-20 dB was typical for non-organic hearing losses and that speech audiometry might show considerably poorer results than expected from pure tone audiometry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Moraxella catarrhalis is an exclusively human commensal and mucosal pathogen. Its role as a disease-causing organism has long been questioned. Today, it is recognized as one of the major causes of acute otitis media in children, and its relative frequency of isolation from both the nasopharynx and the middle ear cavity has increased since the introduction of the heptavalent pneumococcal conjugate vaccine, which is associated with a shift in the composition of the nasopharyngeal flora in infants and young children. Although otitis media caused by M. catarrhalis is generally believed to be mild in comparison with pneumococcal disease, numerous putative virulence factors have now been identified and it has been shown that several surface components of M. catarrhalis induce mucosal inflammation. In adults with chronic obstructive pulmonary disease (COPD), M. catarrhalis is now a well-established trigger of approximately 10% of acute inflammatory exacerbations.Although the so-called cold shock response is a well-described bacterial stress response in species such as Escherichia coli, Bacillus subtilis or - more recently - Staphylococcus aureus, M. catarrhalis is the only typical nasopharyngeal pathogen in which this response has been investigated. Indeed, a 3-h 26°C cold shock, which may occur physiologically, when humans inspire cold air for prolonged periods of time, increases epithelial cell adherence and enhances proinflammatory host responses and may thus contribute to the symptoms referred to as common cold, which typically are attributed to viral infections.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to report a case of squamous cell carcinoma of the petrous part of the temporal bone associated with a long history of secondary acquired cholesteatoma in a 71-year-old man. PATIENTS AND METHODS: We present the case of a 71-year-old man diagnosed with secondary acquired cholesteatoma in 1950. Treatments consisted of repetitive surgery owing to several relapses. In 2004, he presented with progressive fetid otorrhea. Clinical and computed tomography findings were indicative for relapsing cholesteatoma and a subtotal petrosectomy was performed. RESULTS: Histologic work-up demonstrated a moderately differentiated squamous cell carcinoma. The staging revealed stadium pT3 cN0 cM0. Postoperative treatment consisted of local radiation therapy with intensity-modulated beam geometry with a total of 64.2 Gy in 30 fractions using a simultaneous integrated boost. CONCLUSION: Middle ear carcinoma can arise from acquired cholesteatoma. The pathogenesis of squamous cell carcinoma associated with cholesteatoma has not been elucidated satisfactorily. Due to the complex anatomic features, intensity-modulated radiation therapy is the technique of choice for postoperative radiotherapy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION Sound can reach the inner ear via at least two different pathways: air conduction and bone conduction (BC). BC hearing is used clinically for diagnostic purposes and for BC hearing aids. Research on the motion of the human middle ear in response to BC stimulation is typically conducted using cadaver models. We evaluated middle ear motion of Thiel-embalmed whole-head specimens in terms of linearity, reproducibility, and consistency with the reported middle ear motion of living subjects, fresh cadaveric temporal bones, and whole-heads embalmed with a Non-Thiel solution of salts. METHODS We used laser Doppler vibrometry to measure the displacement of the skull, the umbo, the cochlear promontory, the stapes, and the round window in seven ears from four human whole-head specimens embalmed according to Thiel's method. The ears were stimulated with a Baha(®) implanted behind the auricle. RESULTS The Thiel model shows promontory velocity similar to that reported in the literature for whole-heads embalmed with a Non-Thiel solution of salts (0- to 7-dB difference). The Thiel heads' relative velocity of the stapes with respect to the promontory was similar to that of fresh cadaver temporal bones (0- to 4-dB difference). The velocity of the umbo was comparable in Thiel-embalmed heads and living subjects (0- to 10-dB difference). The skull and all middle ear elements measured responded linearly to different stimulation levels, with an average difference less than 1 dB. The variability of repeated measurements for both short- (2 h; 4 dB) and long-term (4-16 weeks; 6 dB) repetitions in the same ear, and the difference between the two ears of the same donor (approximately 10 dB) were lower than the inter-individual difference (up to 25 dB). CONCLUSION Thiel-embalmed human whole-head specimens can be used as an alternative model for the study of human middle ear mechanics secondary to BC stimulation. At some frequencies, differences from living subjects must be considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

HYPOTHESIS A previously developed image-guided robot system can safely drill a tunnel from the lateral mastoid surface, through the facial recess, to the middle ear, as a viable alternative to conventional mastoidectomy for cochlear electrode insertion. BACKGROUND Direct cochlear access (DCA) provides a minimally invasive tunnel from the lateral surface of the mastoid through the facial recess to the middle ear for cochlear electrode insertion. A safe and effective tunnel drilled through the narrow facial recess requires a highly accurate image-guided surgical system. Previous attempts have relied on patient-specific templates and robotic systems to guide drilling tools. In this study, we report on improvements made to an image-guided surgical robot system developed specifically for this purpose and the resulting accuracy achieved in vitro. MATERIALS AND METHODS The proposed image-guided robotic DCA procedure was carried out bilaterally on 4 whole head cadaver specimens. Specimens were implanted with titanium fiducial markers and imaged with cone-beam CT. A preoperative plan was created using a custom software package wherein relevant anatomical structures of the facial recess were segmented, and a drill trajectory targeting the round window was defined. Patient-to-image registration was performed with the custom robot system to reference the preoperative plan, and the DCA tunnel was drilled in 3 stages with progressively longer drill bits. The position of the drilled tunnel was defined as a line fitted to a point cloud of the segmented tunnel using principle component analysis (PCA function in MatLab). The accuracy of the DCA was then assessed by coregistering preoperative and postoperative image data and measuring the deviation of the drilled tunnel from the plan. The final step of electrode insertion was also performed through the DCA tunnel after manual removal of the promontory through the external auditory canal. RESULTS Drilling error was defined as the lateral deviation of the tool in the plane perpendicular to the drill axis (excluding depth error). Errors of 0.08 ± 0.05 mm and 0.15 ± 0.08 mm were measured on the lateral mastoid surface and at the target on the round window, respectively (n =8). Full electrode insertion was possible for 7 cases. In 1 case, the electrode was partially inserted with 1 contact pair external to the cochlea. CONCLUSION The purpose-built robot system was able to perform a safe and reliable DCA for cochlear implantation. The workflow implemented in this study mimics the envisioned clinical procedure showing the feasibility of future clinical implementation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To present the anatomical and functional results of the inside-out technique applied in pediatric cholestetaoma surgery and to evaluate functionality with good hearing results against radicality with lower recurrence rate. METHODS Retrospective analysis and evaluation of the postoperative outcome in a consecutive series of 126 children or 130 ears operated between 1992 and 2008. With the inside-out technique, cholesteatoma is eradicated from the epitympanum toward the mastoid and, as a single stage procedure, functional reconstruction of the middle ear is achieved by tympanoossiculoplasty. RESULTS In 89.2% of all cases, the ear was dry postoperatively. 80.9% of the ears reached a postoperative air-bone gap of 30 dB or less and the median air conduction hearing threshold was 29 dB; in 60.9% of all cases, hearing was postoperatively improved. The recurrence rate was 16.2% in a mean postoperative follow-up 8.5 years. Altogether, 48 ears (36.9%) underwent revision surgery. The complication rate was 3.1% and involved only minor complications. CONCLUSION The inside-out technique allows a safe removal of cholesteatoma from the epitympanum toward the mastoid with a single-stage reconstruction of the ossicular chain. For this reason we support our individual approach, which allows creation of the smallest possible cavity for the size of the cholesteatoma. Our results confirm that the inside-out technique is effective in the treatment of pediatric cholesteatoma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES Cone beam computed tomography (CBCT) is frequently used in treatment planning for alveolar bone grafting (ABG) and orthognathic surgery in patients with cleft lip and palate (CLP). CBCT images may depict coincident findings. The aim of this study was to assess the prevalence of incidental findings on CBCT scans in CLP patients. SUBJECTS AND METHODS Initial CBCTs taken from consecutive patients (n = 187; mean age 11.7 years, range 6.9-45) with a non-syndromic orofacial cleft from January 2006 until June 2012 were systematically evaluated. Twenty-eight patients (mean age 19.3 years, range 13.2-30.9) had been subjected to ABG before their first CBCT was taken; 61 patients had a CBCT before and after ABG. Sinuses, nasopharynx, oropharynx, throat, skull, vertebrae, temporomandibular joint (TMJ), maxilla and mandible were checked for incidental findings. RESULTS On 95.1 % of the CBCTs, incidental findings were found. The most prevalent were airway/sinus findings (56.1 %), followed by dental problems, e.g. missing teeth (52 %), nasal septum deviation (34 %), middle ear and mastoid opacification, suggestive for otitis media (10 %) and (chronic) mastoiditis (9 %), abnormal TMJ anatomy (4.9 %) and abnormal vertebral anatomy (1.6 %). In the 28 patients whose first CBCT was taken at least 2 years after ABG, bone was still present in the reconstructed cleft area except in 2 out of 12 patients with a bilateral CLP. The ABG donor site (all bone grafts were taken from the chin area) was still recognizable in over 50 % of the patients. Based on the CBCT findings, 10 % of the patients were referred for further diagnosis and 9 % for further treatment related to dental problems. CONCLUSION Incidental findings are common on CBCTs. Compared with the literature, CLP patients have more dental, nasal and ear problems. Thus, whenever a CBCT is available, this scan should be reviewed by all specialists in the CLP team focusing on their specific background knowledge concerning symptoms and treatment of these patients. CLINICAL RELEVANCE The high number of findings indicates that CBCT imaging is a helpful tool in the treatment of CLP patients not only related to alveolar bone grafting and orthognathic surgery but it also provides diagnostic information for almost all specialties involved in CLP treatment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A retrospective evaluation of glass ionomer cement (GIC) in middle ear surgery with emphasis on short- and long-term safety was conducted at the tertiary referral center. GIC was applied between 1995 and 2006 in 444 patients in otologic surgery. Technical aspects, safety, benefits and complications due to GIC were analysed until 2011 (follow-up 5-16 years; mean 10 years). GIC was applied in stapes surgery (228 primary, 92 revisions), cochlear implants (108) and implantable hearing aids (7), ossiculoplasty (7), for coverage of opened mastoid air cells towards the external ear canal (1) and inner ear fistula closure (1). GIC turned out to be very handy in stapes surgery for optimal prosthesis fixation at the incus (260) and on the malleus handle (60) without complications. Results suggest that GIC may diminish the danger of incus necrosis in primary stapedotomy. In cochlear implants and implantable hearing aids, GIC was used for casing alone (74), casing and electrode fixation (27) and electrode alone fixation (14). Inflammatory reactions were observed in five cases (4.3 %), mostly after trauma. Broken cement fragments appeared to promote foreign body rejection. In seven cases an incudo-stapedial gap was repaired with GIC with excellent hearing gain; in three cases (43 %) revision surgery was needed due to cement breakage. In one case, GIC was applied for a watertight coverage of opened mastoid cells, and in the other for fistula closure of the lateral semi-circular canal over cartilage, covered with bone pathé; follow-up was uneventful. Targeted use of GIC in middle ear surgery rarely poses problems. GIC cannot be used in neuro-otosurgery in contact with cerebrospinal fluid because of possible aluminium encephalopathy.