Discrepancies in finite-element model predictions of bone strength may be attributed to the simplified modeling of bone as an isotropic structure due to the resolution limitations of clinical-level Computed Tomography (CT) data. The aim of this study is to calculate the preferential orientations of bone (the principal directions) and the extent to which bone is deposited more in one direction compared to another (degree of anisotropy). Using 100 femoral trabecular samples, the principal directions and degree of anisotropy were calculated with a Gradient Structure Tensor (GST) and a Sobel Structure Tensor (SST) using clinical-level CT. The results were compared against those calculated with the gold standard Mean-Intercept-Length (MIL) fabric tensor using micro-CT. There was no significant difference between the GST and SST in the calculation of the main principal direction (median error=28°), and the error was inversely correlated to the degree of transverse isotropy (r=−0.34, p<0.01). The degree of anisotropy measured using the structure tensors was weakly correlated with the MIL-based measurements (r=0.2, p<0.001). Combining the principal directions with the degree of anisotropy resulted in a significant increase in the correlation of the tensor distributions (r=0.79, p<0.001). Both structure tensors were robust against simulated noise, kernel sizes, and bone volume fraction. We recommend the use of the GST because of its computational efficiency and ease of implementation. This methodology has the promise to predict the structural anisotropy of bone in areas with a high degree of anisotropy, and may improve the in vivo characterization of bone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics and during the early phases of healing and incorporation of Straumann dental implants with an SLA surface. MATERIAL AND METHODS: 17 Straumann 4.1 mm implants (10 mm) and 7 Straumann 4.8 mm implants (10 mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1 mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). RESULTS: Pocket probing depths ranged from 2-4 mm and bleeding on probing from 5-20%. At baseline, BVD varied between 24% and 65% and BTC between 4.9 and 25.4 for the 4.1 mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8 mm diameter implants baseline ISQ values ranged from 57-70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1 mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. CONCLUSION: ISQ values of 57-70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since the decrease occurred after the fact.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: - to monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics during the early phases of healing and incorporation of Straumann® dental implants with an SLA surface. Material and methods: 17 Straumann 4.1mm implants (10mm) and 7 Straumann 4.8mm implants (10mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). Results: Pocket probing depths ranged between 2-4mm and bleeding on probing between 5-20%. At baseline, BVD varied between 24 and 65% and BTC between 4.9 and 25.4 for the 4.1mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8mm diameter implants baseline ISQ values ranged from 57 – 70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. Conclusion: ISQ values of 57 – 70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since decease occurred after the fact.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Vasa vasorum (VV) have been implicated to play a role in the pathogenesis of atherosclerosis. This study was designed to describe the distribution of VV density in different vascular beds in humans and to investigate the association between VV density and the known distribution of atherosclerosis in human arteries. METHODS: Forty-two human arteries, harvested at autopsy or after explantation, were analyzed by three-dimensional microscopic-computed tomography (micro-CT). VV density, endothelial-surface-fraction (Sigma VV endothelial-surface-area/vessel-wall-volume) and vascular-area-fraction (Sigma VV area/vessel-wall-area) were calculated for coronary, renal and femoral arteries. Representatively five coronary, renal and femoral arteries were stained for endothelial cells (von Willebrand-Factor), macrophages (CD68), vascular endothelial growth factor (VEGF) and collagen (Sirius Red). RESULTS: Coronary arteries showed a higher VV density compared to renal and femoral arteries (2.12+/-0.26 n/mm(2) versus 0.61+/-0.06 n/mm(2) and 0.66+/-0.11 n/mm(2); P<0.05 for both) as well as a higher endothelial-surface-fraction and vascular-area-fraction. Histology showed a positive correlation between histologically derived VV density and CD68-positive cells/area (r=0.54, P<0.01), VEGF-immunoreactivity/area (r=0.55, P<0.01) and a negative correlation between VV density and collagen I content (r=0.66, P<0.05). CONCLUSION: This micro-CT study highlights a higher VV density in coronary than in peripheral arteries, supporting the relation between VV density and the susceptibility to atherosclerosis in different vascular beds in humans.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Vertebral cement augmentation can restore the stiffness and strength of a fractured vertebra and relieve chronic pain. Previous finite element analysis, biomechanical tests and clinical studies have indirectly associated new adjacent vertebral fractures following augmentation to altered loading. The aim of this repeated measures in situ biomechanical study was to determine the changes in the adjacent and augmented endplate deformation following cement augmentation of human cadaveric functional spine units (FSU) using micro-computed tomography (micro-CT). The surrounding soft tissue and posterior elements of 22 cadaveric human FSU were removed. FSU were assigned to two groups, control (n = 8) (loaded on day 1 and day 2) and augmented (n = 14) (loaded on day 1, augmented 20% cement fill, and loaded on day 2). The augmented group was further subdivided into a prophylactic augmentation group (n = 9), and vertebrae which spontaneously fractured during loading on day 1 (n = 5). The FSU were axially loaded (200, 1,000, 1,500-2,000 N) within a custom made radiolucent, saline filled loading device. At each loading step, FSUs were scanned using the micro-CT. Endplate heights were determined using custom software. No significant increase in endplate deformation following cement augmentation was noted for the adjacent endplate (P > 0.05). The deformation of the augmented endplate was significantly reduced following cement augmentation for both the prophylactic and fracture group (P < 0.05, P < 0.01, respectively). Endplate deformation of the controls showed no statistically significant differences between loading on day 1 and day 2. A linear relationship was noted between the applied compressive load and endplate deflection (R (2) = 0.58). Evidence of significant endplate deformation differences between unaugmented and augmented FSU, while evident for the augmented endplate, was not present for the adjacent endplate. This non-invasive micro-CT method may also be useful to investigate endplate failure, and parameters that predict vertebral failure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pulmonary airways are subdivided into conducting and gas-exchanging airways. An acinus is defined as the small tree of gas-exchanging airways, which is fed by the most distal purely conducting airway. Until now a dissector of five consecutive sections or airway casts were used to count acini. We developed a faster method to estimate the number of acini in young adult rats. Right middle lung lobes were critical point dried or paraffin embedded after heavy metal staining and imaged by X-ray micro-CT or synchrotron radiation-based X-rays tomographic microscopy. The entrances of the acini were counted in three-dimensional (3D) stacks of images by scrolling through them and using morphological criteria (airway wall thickness and appearance of alveoli). Segmentation stopper were placed at the acinar entrances for 3D visualizations of the conducting airways. We observed that acinar airways start at various generations and that one transitional bronchiole may serve more than one acinus. A mean of 5612 (±547) acini per lung and a mean airspace volume of 0.907 (±0.108) μL per acinus were estimated. In 60-day-old rats neither the number of acini nor the mean acinar volume did correlate with the body weight or the lung volume.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right-left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland-Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Despite the worldwide increased prevalence of osteoporosis, no data are available evaluating the effect of an enamel matrix derivative (EMD) on the healing of periodontal defects in patients with osteoporosis. This study aims to evaluate whether the regenerative potential of EMD may be suitable for osteoporosis-related periodontal defects. METHODS Forty female Wistar rats (mean body weight: 200 g) were used for this study. An osteoporosis animal model was carried out by bilateral ovariectomy (OVX) in 20 animals. Ten weeks after OVX, bilateral fenestration defects were created at the buccal aspect of the first mandibular molar. Animals were randomly assigned to four groups of 10 animals per group: 1) control animals with unfilled periodontal defects; 2) control animals with EMD-treated defects; 3) OVX animals with unfilled defects; and 4) OVX animals with EMD-treated defects. The animals were euthanized 28 days later, and the percentage of defect fill and thickness of newly formed bone and cementum were assessed by histomorphometry and microcomputed tomography (micro-CT) analysis. The number of osteoclasts was determined by tartrate-resistant acid phosphatase (TRAP), and angiogenesis was assessed by analyzing formation of blood vessels. RESULTS OVX animals demonstrated significantly reduced bone volume in unfilled defects compared with control defects (18.9% for OVX animals versus 27.2% for control animals) as assessed by micro-CT. The addition of EMD in both OVX and control animals resulted in significantly higher bone density (52.4% and 69.2%, respectively) and bone width (134 versus 165μm) compared with untreated defects; however, the healing in OVX animals treated with EMD was significantly lower than that in control animals treated with EMD. Animals treated with EMD also demonstrated significantly higher cementum formation in both control and OVX animals. The number of TRAP-positive osteoclasts did not vary between untreated and EMD-treated animals; however, a significant increase was observed in all OVX animals. The number of blood vessels and percentage of new vessel formation was significantly higher in EMD-treated samples. CONCLUSIONS The results from the present study suggest that: 1) an osteoporotic phenotype may decrease periodontal regeneration; and 2) EMD may support greater periodontal regeneration in patients suffering from the disease. Additional clinical studies are necessary to fully elucidate the possible beneficial effect of EMD for periodontal regeneration in patients suffering from osteoporosis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Facial nerve segmentation plays an important role in surgical planning of cochlear implantation. Clinically available CBCT images are used for surgical planning. However, its relatively low resolution renders the identification of the facial nerve difficult. In this work, we present a supervised learning approach to enhance facial nerve image information from CBCT. A supervised learning approach based on multi-output random forest was employed to learn the mapping between CBCT and micro-CT images. Evaluation was performed qualitatively and quantitatively by using the predicted image as input for a previously published dedicated facial nerve segmentation, and cochlear implantation surgical planning software, OtoPlan. Results show the potential of the proposed approach to improve facial nerve image quality as imaged by CBCT and to leverage its segmentation using OtoPlan.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM Vitamin D deficiency is considered to diminish bone regeneration. Yet, raising the serum levels takes months. A topic application of the active vitamin D metabolite, calcitriol, may be an effective approach. Thus, it becomes important to know the effect of vitamin D deficiency and local application on alveolar bone regeneration. MATERIAL AND METHODS Sixty rats were divided into three groups; two vitamin depletion groups and a control group. Identical single defects (2 mm diameter) were created in the maxilla and mandible treated with calcitriol soaked collagen in one deficiency group while in the other two groups not. Histomorphometric analysis and micro CTs were performed after 1 and 3 weeks. Serum levels of 25(OH)D3 and PTH were determined. RESULTS Bone formation rate significantly increased within the observation period in all groups. Bone regeneration was higher in the maxilla than in the mandible. However, bone regeneration was lower in the control group compared to vitamin depletion groups, with no significant effects by local administration of calcitriol (micro CT mandible p = 0.003, maxilla p < 0.001; histomorphometry maxilla p = 0.035, mandible p = 0.18). CONCLUSION Vitamin D deficiency not necessarily impairs bone regeneration in the rat jaw and a single local calcitriol application does not enhance healing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION Since the initial publication in 2000, Angiotensin II-infused mice have become one of the most popular models to study abdominal aortic aneurysm in a pre-clinical setting. We recently used phase contrast X-ray based computed tomography to demonstrate that these animals develop an apparent luminal dilatation and an intramural hematoma, both related to mural ruptures in the tunica media in the vicinity of suprarenal side branches. AIMS The aim of this narrative review was to provide an extensive overview of small animal applicable techniques that have provided relevant insight into the pathogenesis and morphology of dissecting AAA in mice, and to relate findings from these techniques to each other and to our recent PCXTM-based results. Combining insights from recent and consolidated publications we aimed to enhance our understanding of dissecting AAA morphology and anatomy. RESULTS AND CONCLUSION We analyzed in vivo and ex vivo images of aortas obtained from macroscopic anatomy, histology, high-frequency ultrasound, contrast-enhanced micro-CT, micro-MRI and PCXTM. We demonstrate how in almost all publications the aorta has been subdivided into a part in which an intact lumen lies adjacent to a remodeled wall/hematoma, and a part in which elastic lamellae are ruptured and the lumen appears to be dilated. We show how the novel paradigm fits within the existing one, and how 3D images can explain and connect previously published 2D structures. We conclude that PCXTM-based findings are in line with previous results, and all evidence points towards the fact that dissecting AAAs in Angiotensin II-infused mice are actually caused by ruptures of the tunica media in the immediate vicinity of small side branches.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The regenerative pathways during periosteal distraction osteogenesis may be influenced by the local environment composed by cells, growth factors, nutrition and mechanical load. The aim of the present study was to evaluate the influence of two protocols of periosteal distraction on bone formation. Custom made distraction devices were surgically fixed onto the calvariae of 60 rabbits. After an initial healing period of 7 days, two groups of animals were submitted to distraction rates of 0.25 and 0.5 mm/24 h for 10 days, respectively. Six animals per group were sacrificed 10 (mid-distraction), 17 (end-distraction), 24 (1-week consolidation), 31 (2-week consolidation) and 77 days (2-month consolidation) after surgery. Newly formed bone was assessed by means of micro-CT and histologically. Expression of transcripts encoding tissue-specific genes (BMP-2, RUNX2, ACP5, SPARC, collagen I α1, collagen II α1 and SOX9) was analyzed by quantitative PCR. Two patterns of bone formation were observed, originating from the old bone surface in Group I and from the periosteum in Group II. Bone volume (BV) and bone mineral density (BMD) significantly increased up to the 2-month consolidation period within the groups (p < 0.05). Significantly more bone was observed in Group II compared to Group I at the 2-month consolidation period (p < 0.001). Expression of transcripts encoding osteogenic genes in bone depended on the time-point of observation (p < 0.05). Low level of transcripts reveals an indirect role of periosteum in the osteogenic process. Two protocols of periosteal distraction in the present model resulted in moderate differences in terms of bone formation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The interest in automatic volume meshing for finite element analysis (FEA) has grown more since the appearance of microfocus CTCT), due to its high resolution, which allows for the assessment of mechanical behaviour at a high precision. Nevertheless, the basic meshing approach of generating one hexahedron per voxel produces jagged edges. To prevent this effect, smoothing algorithms have been introduced to enhance the topology of the mesh. However, whether smoothing also improves the accuracy of voxel-based meshes in clinical applications is still under question. There is a trade-off between smoothing and quality of elements in the mesh. Distorted elements may be produced by excessive smoothing and reduce accuracy of the mesh. In the present work, influence of smoothing on the accuracy of voxel-based meshes in micro-FE was assessed. An accurate 3D model of a trabecular structure with known apparent mechanical properties was used as a reference model. Virtual CT scans of this reference model (with resolutions of 16, 32 and 64 μm) were then created and used to build voxel-based meshes of the microarchitecture. Effects of smoothing on the apparent mechanical properties of the voxel-based meshes as compared to the reference model were evaluated. Apparent Young’s moduli of the smooth voxel-based mesh were significantly closer to those of the reference model for the 16 and 32 μm resolutions. Improvements were not significant for the 64 μm, due to loss of trabecular connectivity in the model. This study shows that smoothing offers a real benefit to voxel-based meshes used in micro-FE. It might also broaden voxel-based meshing to other biomechanical domains where it was not used previously due to lack of accuracy. As an example, this work will be used in the framework of the European project ContraCancrum, which aims at providing a patient-specific simulation of tumour development in brain and lungs for oncologists. For this type of clinical application, such a fast, automatic, and accurate generation of the mesh is of great benefit.