51 resultados para medication error
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The purpose of this study was (1) to determine frequency and type of medication errors (MEs), (2) to assess the number of MEs prevented by registered nurses, (3) to assess the consequences of ME for patients, and (4) to compare the number of MEs reported by a newly developed medication error self-reporting tool to the number reported by the traditional incident reporting system. We conducted a cross-sectional study on ME in the Cardiovascular Surgery Department of Bern University Hospital in Switzerland. Eligible registered nurses (n = 119) involving in the medication process were included. Data on ME were collected using an investigator-developed medication error self reporting tool (MESRT) that asked about the occurrence and characteristics of ME. Registered nurses were instructed to complete a MESRT at the end of each shift even if there was no ME. All MESRTs were completed anonymously. During the one-month study period, a total of 987 MESRTs were returned. Of the 987 completed MESRTs, 288 (29%) indicated that there had been an ME. Registered nurses reported preventing 49 (5%) MEs. Overall, eight (2.8%) MEs had patient consequences. The high response rate suggests that this new method may be a very effective approach to detect, report, and describe ME in hospitals.
Predictors of health care professionals' attitudes towards involvement in safety-relevant behaviours
Resumo:
BACKGROUND Patients can make valuable contributions towards promoting the safety of their health care. Health care professionals (HCPs) could play an important role in encouraging patient involvement in safety-relevant behaviours. However, to date factors that determine HCPs' attitudes towards patient participation in this area remain largely unexplored. OBJECTIVE To investigate predictors of HCPs' attitudes towards patient involvement in safety-relevant behaviours. DESIGN A 22-item cross-sectional fractional factorial survey that assessed HCPs' attitudes towards patient involvement in relation to two error scenarios relating to hand hygiene and medication safety. SETTING Four hospitals in London PARTICIPANTS Two hundred sixteen HCPs (116 doctors; 100 nurses) aged between 21 and 60 years (mean: 32): 129 female. OUTCOME MEASURES Approval of patient's behaviour, HCP response to the patient, anticipated effects on the patient-HCP relationship, support for being asked as a HCP, affective rating response to the vignettes. RESULTS HCPs elicited more favourable attitudes towards patients intervening about a medication error than about hand sanitation. Across vignettes and error scenarios, the strongest predictors of attitudes were how the patient intervened and how the HCP responded to the patient's behaviour. With regard to HCP characteristics, doctors viewed patients intervening less favourably than nurses. CONCLUSIONS HCPs perceive patients intervening about a potential error less favourably if the patient's behaviour is confrontational in nature or if the HCP responds to the patient intervening in a discouraging manner. In particular, if a HCP responds negatively to the patient (irrespective of whether an error actually occurred), this is perceived as having negative effects on the HCP-patient relationship.
Resumo:
OBJECTIVES: To analyse the frequency of and identify risk factors for patient-reported medical errors in Switzerland. The joint effect of risk factors on error-reporting probability was modelled for hypothetical patients. METHODS: A representative population sample of Swiss citizens (n = 1306) was surveyed as part of the Commonwealth Fund’s 2010 lnternational Survey of the General Public’s Views of their Health Care System’s Performance in Eleven Countries. Data on personal background, utilisation of health care, coordination of care problems and reported errors were assessed. Logistic regression analysis was conducted to identify risk factors for patients’ reports of medical mistakes and medication errors. RESULTS: 11.4% of participants reported at least one error in their care in the previous two years (8% medical errors, 5.3% medication errors). Poor coordination of care experiences was frequent. 7.8% experienced that test results or medical records were not available, 17.2% received conflicting information from care providers and 11.5% reported that tests were ordered although they had been done before. Age (OR = 0.98, p = 0.014), poor health (OR = 2.95, p = 0.007), utilisation of emergency care (OR = 2.45, p = 0.003), inpatient-stay (OR = 2.31, p = 0.010) and poor care coordination (OR = 5.43, p <0.001) are important predictors for reporting error. For high utilisers of care that unify multiple risk factors the probability that errors are reported rises up to p = 0.8. CONCLUSIONS: Patient safety remains a major challenge for the Swiss health care system. Despite the health related and economic burden associated with it, the widespread experience of medical error in some subpopulations also has the potential to erode trust in the health care system as a whole.
Resumo:
In clinical medicine, plane radiography is used for detecting the remains of medications in the stomach in oral medication intoxication cases. Since postmortem computed tomography (CT), performed prior to autopsy, is currently intensively entering the forensic routine, the technique was applied to three fatal cases of oral medication intoxication. Here we report CT and autopsy findings for these cases. In all three cases, hyperdense areas within the stomach content were documented. The measurement of Hounsfield Units (HU) beyond 74HU showed mean values of 338, 88 and 98HU. Postmortem CT also showed brain edema and pulmonary aspiration in one case. At autopsy, tablet remains in the stomach were detected microscopically in all three cases. The ex vivo CT scans of the ingested medicaments showed similar HU values. Despite the fact that further case studies are necessary beyond this one, and in spite of its limitations, postmortem CT was found to be a useful screening and documentation method for stomach contents in oral medication intoxication.
Resumo:
Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.
Resumo:
Children with attention-deficit/hyperactivity disorder (ADHD) show a marked temporal variability in their display of symptoms and neuropsychological performance. This could be explained in terms of an impaired glial supply of energy to support neuronal activity.
Resumo:
Patients can make contributions to the safety of chemotherapy administration but little is known about their motivations to participate in safety-enhancing strategies. The theory of planned behavior was applied to analyze attitudes, norms, behavioral control, and chemotherapy patients' intentions to participate in medical error prevention.
Resumo:
Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.
Resumo:
Purpose The accuracy, efficiency, and efficacy of four commonly recommended medication safety assessment methodologies were systematically reviewed. Methods Medical literature databases were systematically searched for any comparative study conducted between January 2000 and October 2009 in which at least two of the four methodologies—incident report review, direct observation, chart review, and trigger tool—were compared with one another. Any study that compared two or more methodologies for quantitative accuracy (adequacy of the assessment of medication errors and adverse drug events) efficiency (effort and cost), and efficacy and that provided numerical data was included in the analysis. Results Twenty-eight studies were included in this review. Of these, 22 compared two of the methodologies, and 6 compared three methods. Direct observation identified the greatest number of reports of drug-related problems (DRPs), while incident report review identified the fewest. However, incident report review generally showed a higher specificity compared to the other methods and most effectively captured severe DRPs. In contrast, the sensitivity of incident report review was lower when compared with trigger tool. While trigger tool was the least labor-intensive of the four methodologies, incident report review appeared to be the least expensive, but only when linked with concomitant automated reporting systems and targeted follow-up. Conclusion All four medication safety assessment techniques—incident report review, chart review, direct observation, and trigger tool—have different strengths and weaknesses. Overlap between different methods in identifying DRPs is minimal. While trigger tool appeared to be the most effective and labor-efficient method, incident report review best identified high-severity DRPs.
Resumo:
Medical errors are a serious threat to chemotherapy patients. Patients can make contributions to safety but little is known about the acceptability of error-preventing behaviors and its predictors.
Resumo:
PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0-not visualized; 3-excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3mm versus 4.9±1.3mm [P<0.05] and 3.7±1.3mm versus 2.6±0.5mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.