5 resultados para mechanical pre-dewatering

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the peri-operative analgesic efficacy of intra-articular bupivacaine administered before or after stifle arthrotomy. STUDY DESIGN: Prospective, randomized, blind, placebo-controlled experimental trial. ANIMALS: Thirty-nine healthy goats. METHODS: The goats were allocated randomly to one of three intra-articular treatment groups: group PRE (bupivacaine before and saline after surgery), group POST (saline before and bupivacaine after surgery) and group CON (saline before and after surgery). Anaesthesia was maintained with a constant end-tidal sevoflurane of 2.5%. Intra-operatively heart rate (HR), respiratory rate and mean arterial blood pressure (MAP) after critical surgical events (CSE) were recorded and compared with pre-incision values. Propofol requirements to maintain surgical anaesthesia were recorded. Flunixin was administered for 5 days. Post-operative pain assessment at 20 minutes, 2 hours, 4 hours after recovery and on day 2 and 3 included a multidimensional pain score (MPS), a lameness score and mechanical nociceptive threshold (MNT) testing. Rescue analgesia consisted of systemic opioids. Data were analysed using Kruskal-Wallis, Mann-Whitney, Friedman or chi-square tests as appropriate. RESULTS: Intra-operatively, group PRE had lower HR and MAP at several CSEs than groups POST/CON and required less propofol [0 mg kg(-1) (0-0 mg kg(-1))] than group POST/CON [0.3 mg kg(-1) (0-0.6 mg kg(-1))]. Post-operatively, group POST had significantly higher peri-articular MNTs than groups PRE and CON up to 4 hours after recovery. No treatment effect was detected for MPS, lameness scores and rescue analgesic consumption at any time point. CONCLUSIONS AND CLINICAL RELEVANCE: Pre-operative intra-articular bupivacaine provided notable intra-operative analgesia in goats undergoing stifle arthrotomy but did not reduce post-operative pain. Post-operative intra-articular bupivacaine provided a short lasting reduction of peri-articular hyperalgesia without affecting the requirements for systemic analgesia. Multimodal perioperative pain therapy is recommended to provide adequate analgesia for stifle arthrotomy in goats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Sevoflurane exerts effects on pulmonary cells that could protect against lung injury. We evaluated the potential of pretreatment with sevoflurane to attenuate lipopolysaccharide (LPS)-induced lung injury. Methods: LPS was administered intratracheally in Wistar rats to induce lung injury. Sevoflurane was administered for 30 min at 0.25, 0.5 or 1.0 MAC 15 min before LPS or for 30min at 0.5 MAC 24 hours before LPS. After initial analysis of bronchoalveolar lavage fluid (BALF) cells and total protein, the group of 0.5 MAC 15min before LPS was further analyzed for surfactant aggregates subfractions, plasma malondialdehyde levels and lung histology. Results: LPS instillation resulted in neutrophils sequestration in the lungs, loss of alveolar macrophages, increased BALF total protein and decreased large surfactant aggregates. Only inhalation of sevoflurane for 30min at 0.5 MAC 15min before LPS installation effectively reduced neutrophil accumulation, preserved alveolar epithelial cells and reduced total protein content in BALF. This regimen also reduced plasma malondialdehyde levels and increased large surfactant aggregates, despite the application of mechanical ventilation. This effect was preserved after LPS instillation and the favorable composition of surfactant was maintained. Conclusions: Pretreatment with sevoflurane effectively attenuates direct severe lung injury, possibly by inhibition of neutrophil accumulation and alteration of the surfactant composition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The finite element analysis is an accepted method to predict vertebral body compressive strength. This study compares measurements obtained from in vitro tests with the ones from two different simulation models: clinical quantitative computer tomography (QCT) based homogenized finite element (hFE) models and pre-clinical high-resolution peripheral QCT-based (HR-pQCT) hFE models. About 37 vertebral body sections were prepared by removing end-plates and posterior elements, scanned with QCT (390/450μm voxel size) as well as HR-pQCT (82μm voxel size), and tested in compression up to failure. Non-linear viscous damage hFE models were created from QCT/HT-pQCT images and compared to experimental results based on stiffness and ultimate load. As expected, the predictability of QCT/HR-pQCT-based hFE models for both apparent stiffness (r2=0.685/0.801r2=0.685/0.801) and strength (r2=0.774/0.924r2=0.774/0.924) increased if a better image resolution was used. An analysis of the damage distribution showed similar damage locations for all cases. In conclusion, HR-pQCT-based hFE models increased the predictability considerably and do not need any tuning of input parameters. In contrast, QCT-based hFE models usually need some tuning but are clinically the only possible choice at the moment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION An accurate description of the biomechanical behavior of the spine is crucial for the planning of scoliotic surgical correction as well as for the understanding of degenerative spine disorders. The current clinical assessments of spinal mechanics such as side-bending or fulcrum-bending tests rely on the displacement of the spine observed during motion of the patient. Since these tests focused solely on the spinal kinematics without considering mechanical loads, no quantification of the mechanical flexibility of the spine can be provided. METHODS A spinal suspension test (SST) has been developed to simultaneously monitor the force applied on the spine and the induced vertebral displacements. The system relies on cervical elevation of the patient and orthogonal radiographic images are used to measure the position of the vertebras. The system has been used to quantify the spinal flexibility on five AIS patients. RESULTS Based on the SST, the overall spinal flexibility varied between 0.3 °/Nm for the patient with the stiffer curve and 2 °/Nm for the less rigid curve. A linear correlation was observed between the overall spinal flexibility and the change in Cobb angle. In addition, the segmental flexibility calculated for five segments around the apex was 0.13 ± 0.07 °/Nm, which is similar to intra-operative stiffness measurements previously published. CONCLUSIONS In summary, the SST seems suitable to provide pre-operative information on the complex functional behavior and stiffness of spinal segments under physiological loading conditions. Such tools will become increasingly important in the future due to the ever-increasing complexity of the surgical instrumentation and procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hydrogels have been described as ideal scaffolds for cells of 3D tissue constructs and hold strong promises with respect to in vitro 3D-cell-culture, where cells are isolated from native extracellular matrix (ECM). Synthesized polyethyleneglycol (PEG) hydrogels are appealing with regard to potential for cell therapy or as vehicles for drug delivery or even to regenerate tissue with similar hydrogel-like properties such as the nucleus pulposus of the intervertebral disc (IVD). Here, we tested whether incorporation of RGD motive would hinder discogenic differentiation of primary bone marrow-derived human mesenchymal stem cells (hMSCs) but favor proliferation of undifferentiated hMSCs. HMSCs were embedded in +RGD containing or without RGD PEG hydrogel and pre-conditioned with or without growth and differentiation factor-5 (rhGDF-5) for 13 days. Afterwards, all hMSCs-PEG gels were subsequently cyclically loaded (15% strain, 1Hz) for 5 consecutive days in a bioreactor to generate an IVD-like phenotype. Higher metabolic activity (resazurin assay) was found in groups with rhGDF5 in both gel types with and without RGD. Cell viability and morphology measured by confocal laser microscopy and DNA content showed decreased values (~60%) after 18 days of culture. Real-time RT-PCR of an array of 15 key genes suspected to be distinctive for IVD cells revealed moderate response to rhGDF5 and mechanical loading as also shown by histology staining. Preconditioning and mechanical loading showed relatively moderate responses revealed from both RT-PCR and histology although hMSCs were demonstrated to be potent to differentiate into chondrocyte-progenitor cells in micro- mass and 3D alginate bead culture.