101 resultados para mean arterial pressure

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

THE AIM OF THE STUDY There are limited data on blood pressure targets and vasopressor use following cardiac arrest. We hypothesized that hypotension and high vasopressor load are associated with poor neurological outcome following out-of-hospital cardiac arrest (OHCA). METHODS We included 412 patients with OHCA included in FINNRESUSCI study conducted between 2010 and 2011. Hemodynamic data and vasopressor doses were collected electronically in one, two or five minute intervals. We evaluated thresholds for time-weighted (TW) mean arterial pressure (MAP) and outcome by receiver operating characteristic (ROC) curve analysis, and used multivariable analysis adjusting for co-morbidities, factors at resuscitation, an illness severity score, TW MAP and total vasopressor load (VL) to test associations with one-year neurologic outcome, dichotomized into either good (1-2) or poor (3-5) according to the cerebral performance category scale. RESULTS Of 412 patients, 169 patients had good and 243 patients had poor one-year outcomes. The lowest MAP during the first six hours was 58 (inter-quartile range [IQR] 56-61) mmHg in those with a poor outcome and 61 (59-63) mmHg in those with a good outcome (p<0.01), and lowest MAP was independently associated with poor outcome (OR 1.02 per mmHg, 95% CI 1.00-1.04, p=0.03). During the first 48h the median (IQR) of the TW mean MAP was 80 (78-82) mmHg in patients with poor, and 82 (81-83) mmHg in those with good outcomes (p=0.03) but in multivariable analysis TWA MAP was not associated with outcome. Vasopressor load did not predict one-year neurologic outcome. CONCLUSIONS Hypotension occurring during the first six hours after cardiac arrest is an independent predictor of poor one-year neurologic outcome. High vasopressor load was not associated with poor outcome and further randomized trials are needed to define optimal MAP targets in OHCA patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The objective of this study was to evaluate the effects of two different mean arterial blood pressure (MAP) targets on needs for resuscitation, organ dysfunction, mitochondrial respiration and inflammatory response in a long-term model of fecal peritonitis. METHODS: Twenty-four anesthetized and mechanically ventilated pigs were randomly assigned (n = 8/group) to a septic control group (septic-CG) without resuscitation until death or one of two groups with resuscitation performed after 12 hours of untreated sepsis for 48 hours, targeting MAP 50-60 mmHg (low-MAP) or 75-85 mmHg (high-MAP). RESULTS: MAP at the end of resuscitation was 56 ± 13 mmHg (mean ± SD) and 76 ± 17 mmHg respectively, for low-MAP and high-MAP groups. One animal each in high- and low-MAP groups, and all animals in septic-CG died (median survival time: 21.8 hours, inter-quartile range: 16.3-27.5 hours). Norepinephrine was administered to all animals of the high-MAP group (0.38 (0.21-0.56) mcg/kg/min), and to three animals of the low-MAP group (0.00 (0.00-0.25) mcg/kg/min; P = 0.009). The high-MAP group had a more positive fluid balance (3.3 ± 1.0 mL/kg/h vs. 2.3 ± 0.7 mL/kg/h; P = 0.001). Inflammatory markers, skeletal muscle ATP content and hemodynamics other than MAP did not differ between low- and high-MAP groups. The incidence of acute kidney injury (AKI) after 12 hours of untreated sepsis was, respectively for low- and high-MAP groups, 50% (4/8) and 38% (3/8), and in the end of the study 57% (4/7) and 0% (P = 0.026). In septic-CG, maximal isolated skeletal muscle mitochondrial Complex I, State 3 respiration increased from 1357 ± 149 pmol/s/mg to 1822 ± 385 pmol/s/mg, (P = 0.020). In high- and low-MAP groups, permeabilized skeletal muscle fibers Complex IV-state 3 respiration increased during resuscitation (P = 0.003). CONCLUSIONS: The MAP targets during resuscitation did not alter the inflammatory response, nor affected skeletal muscle ATP content and mitochondrial respiration. While targeting a lower MAP was associated with increased incidence of AKI, targeting a higher MAP resulted in increased net positive fluid balance and vasopressor load during resuscitation. The long-term effects of different MAP targets need to be evaluated in further studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association between arterial blood pressure (ABP) during the first 24 h and mortality in sepsis. DESIGN: Retrospective cohort study. SETTING: Multidisciplinary intensive care unit (ICU). PATIENTS AND PARTICIPANTS: A total of 274 septic patients. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: Hemodynamic, and laboratory parameters were extracted from a PDMS database. The hourly time integral of ABP drops below clinically relevant systolic arterial pressure (SAP), mean arterial pressure (MAP), and mean perfusion pressure (MPP = MAP - central venous pressure) levels was calculated for the first 24 h after ICU admission and compared with 28-day-mortality. Binary and linear regression models (adjusted for SAPS II as a measure of disease severity), and a receiver operating characteristic (ROC) analysis were applied. The areas under the ROC curve were largest for the hourly time integrals of ABP drops below MAP 60 mmHg (0.779 vs. 0.764 for ABP drops below MAP 55 mmHg; P < or = 0.01) and MPP 45 mmHg. No association between the hourly time integrals of ABP drops below certain SAP levels and mortality was detected. One or more episodes of MAP < 60 mmHg increased the risk of death by 2.96 (CI 95%, 1.06-10.36, P = 0.04). The area under the ROC curve to predict the need for renal replacement therapy was highest for the hourly time integral of ABP drops below MAP 75 mmHg. CONCLUSIONS: A MAP level > or = 60 mmHg may be as safe as higher MAP levels during the first 24 h of ICU therapy in septic patients. A higher MAP may be required to maintain kidney function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arterial pressure-based cardiac output monitors (APCOs) are increasingly used as alternatives to thermodilution. Validation of these evolving technologies in high-risk surgery is still ongoing. In liver transplantation, FloTrac-Vigileo (Edwards Lifesciences) has limited correlation with thermodilution, whereas LiDCO Plus (LiDCO Ltd.) has not been tested intraoperatively. Our goal was to directly compare the 2 proprietary APCO algorithms as alternatives to pulmonary artery catheter thermodilution in orthotopic liver transplantation (OLT). The cardiac index (CI) was measured simultaneously in 20 OLT patients at prospectively defined surgical landmarks with the LiDCO Plus monitor (CI(L)) and the FloTrac-Vigileo monitor (CI(V)). LiDCO Plus was calibrated according to the manufacturer's instructions. FloTrac-Vigileo did not require calibration. The reference CI was derived from pulmonary artery catheter intermittent thermodilution (CI(TD)). CI(V)-CI(TD) bias ranged from -1.38 (95% confidence interval = -2.02 to -0.75 L/minute/m(2), P = 0.02) to -2.51 L/minute/m(2) (95% confidence interval = -3.36 to -1.65 L/minute/m(2), P < 0.001), and CI(L)-CI(TD) bias ranged from -0.65 (95% confidence interval = -1.29 to -0.01 L/minute/m(2), P = 0.047) to -1.48 L/minute/m(2) (95% confidence interval = -2.37 to -0.60 L/minute/m(2), P < 0.01). For both APCOs, bias to CI(TD) was correlated with the systemic vascular resistance index, with a stronger dependence for FloTrac-Vigileo. The capability of the APCOs for tracking changes in CI(TD) was assessed with a 4-quadrant plot for directional changes and with receiver operating characteristic curves for specificity and sensitivity. The performance of both APCOs was poor in detecting increases and fair in detecting decreases in CI(TD). In conclusion, the calibrated and uncalibrated APCOs perform differently during OLT. Although the calibrated APCO is less influenced by changes in the systemic vascular resistance, neither device can be used interchangeably with thermodilution to monitor cardiac output during liver transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To examine whether high levels of self-efficacy for problem-focused coping were significantly related to several resting BP measures in spousal Alzheimer's disease caregivers. Design. Cross-sectional. Methods. Participants included 100 older caregivers (mean age = 73.8 ± 8.14 years) providing in home care for a spouse with Alzheimer's disease. All participants completed a 13-item short form of the Coping Self-Efficacy Scale and underwent an in-home assessment where a visiting nurse took the average of three serial BP readings. Multiple regression was used to examine the relationship between self-efficacy and mean arterial pressure (MAP), systolic BP (SBP), diastolic BP (DBP), and pulse pressure (PP) after controlling for age, gender, smoking history, body mass index, the care recipient's clinical dementia rating, diabetes, alcohol use, and the use of antihypertensive medications. Results. Overall, high levels of self-efficacy for problem-focused coping were associated with lower MAP, SBP, and PP. Self-efficacy for problem-focused coping was marginally associated with resting DBP, but not significant. In addition, we conducted secondary analyses of the other two self-efficacy scales to explore the relationship between each dimension and MAP. We found that there were no significant relationships found between MAP and self-efficacy for stopping unpleasant thoughts/emotions or self-efficacy for getting social support. Conclusions. The present study adds to the current body of literature by illustrating the possibility that higher self-efficacy can have physiological advantages, perhaps by buffering chronic stress's impact on resting BP. Another contribution of the current study is its attempt to understand the role of each individual component of self-efficacy. These findings invite future research to investigate whether caregivers might experience cardiovascular benefits from interventions aimed at enhancing self-efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: A combination of high engagement in pleasurable activities and low perceived activity restriction is potentially protective for a number of health and quality of life outcomes. This study tests the newly proposed Pleasant Events and Activity Restriction (PEAR) model to explain level of blood pressure (BP) in a sample of elderly dementia caregivers. Methods: This cross-sectional study included 66 caregivers, ≥55 years of age, providing in-home care to a relative with dementia. Planned comparisons were made to assess group differences in BP between caregivers reporting high engagement in pleasant events plus low perceived activity restriction (HPLR; n = 22) to those with low pleasure plus high restriction (LPHR; n = 23) or those with either high pleasure plus high restriction or low pleasure plus low restriction (HPHR/LPLR; n = 21). Results: After adjustments for age, sex, body mass index, use of antihypertensive medication, physical activity, and number of health problems, HPLR participants (86.78 mm|Hg) had significantly lower mean arterial pressure compared with LPHR participants (94.70 mm|Hg) (p = .01, Cohen's d = 0.89) and HPHR/LPLR participants (94.84 mm|Hg) (p = .023, d = 0.91). Similar results were found in post hoc comparisons of both systolic and diastolic BP. Conclusions: This study extends support for the PEAR model to physical health outcomes. Differences in BP between the HPLR group and other groups were of large magnitude and thus clinically meaningful. The findings may inform intervention studies aimed at investigating whether increasing pleasant events and lowering perceived activity restriction may lower BP. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Digital volume pulse (DVP), a noninvasive method for indirect assessment of arterial stiffness, was not tested previously in patients with end-stage renal disease (ESRD). Therefore, we compared the DVP-derived stiffness index (SI(DVP)) with aortic pulse wave velocity (PWV) determined by means of Doppler ultrasonography in 2 groups of patients with ESRD and analyzed the correlation between SI(DVP) and comorbidity. METHODS: Photoplethysmography was performed on the index finger of the dominant hand or the hand from the nonfistula arm in 49 renal transplant (TX) recipients and 48 hemodialysis (HD) patients. Pulse curves were analyzed with computer assistance. Comorbidity was assessed by using an established index. RESULTS: The intrasubject variability of SI(DVP) was 5.7%. SI(DVP) and aortic PWV values correlated significantly (r = 0.66; P = 0.001) in patients with ESRD. SI(DVP) could not be assessed reliably in 25% and 6% of HD patients and TX recipients, respectively. Multivariate regression analyses showed that SI(DVP) increased with age in both HD patients and TX recipients (r = 0.61; P < 0.001) and with systolic blood pressure (r = 0.53; P < 0.025), mean arterial pressure (r = 0.47; P < 0.05), and pulse pressure (r = 0.52; P = 0.02) in TX recipients. Severity of comorbid status was associated highly with individual residuals of age-adjusted SI(DVP) in HD patients and TX recipients (P < 0.001). CONCLUSION: DVP allows the measurement of arterial stiffness in most, but not all, patients with ESRD. SI(DVP) values correlate with comorbidity in HD patients and TX recipients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Insufficient blood flow and oxygenation in the intestinal tract is associated with increased incidence of postoperative complications after bowel surgery. High fluid volume administration may prevent occult regional hypoperfusion and intestinal tissue hypoxia. We tested the hypothesis that high intraoperative fluid volume administration increases intestinal wall tissue oxygen pressure during laparotomy. METHODS: In all, 27 pigs were anaesthetized, ventilated and randomly assigned to one of the three treatment groups (n = 9 in each) receiving low (3 mL kg-1 h-1), medium (7 mL kg-1 h-1) or high (20 mL kg-1 h-1) fluid volume treatment with lactated Ringer's solution. All animals received 30% and 100% inspired oxygen in random order. Cardiac index was measured with thermodilution and tissue oxygen pressure with a micro-oximetry system in the jejunum and colon wall and subcutaneous tissue. RESULTS: Groups receiving low and medium fluid volume treatment had similar systemic haemodynamics. The high fluid volume group had significantly higher mean arterial pressure, cardiac index and subcutaneous tissue oxygenation. Tissue oxygen pressures in the jejunum and colon were comparable in all three groups. CONCLUSIONS: The three different fluid volume regimens tested did not affect tissue oxygen pressure in the jejunum and colon, suggesting efficient autoregulation of intestinal blood flow in healthy subjects undergoing uncomplicated abdominal surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: INTRODUCTION: Low blood pressure, inadequate tissue oxygen delivery and mitochondrial dysfunction have all been implicated in the development of sepsis-induced organ failure. This study evaluated the effect on liver mitochondrial function of using norepinephrine to increase blood pressure in experimental sepsis. METHODS: Thirteen anaesthetized pigs received endotoxin (Escherichia coli lipopolysaccharide B0111:B4; 0.4 mug/kg per hour) and were subsequently randomly assigned to norepinephrine treatment or placebo for 10 hours. Norepinephrine dose was adjusted at 2-hour intervals to achieve 15 mmHg increases in mean arterial blood pressure up to 95 mmHg. Systemic (thermodilution) and hepatosplanchnic (ultrasound Doppler) blood flow were measured at each step. At the end of the experiment, hepatic mitochondrial oxygen consumption (high-resolution respirometry) and citrate synthase activity (spectrophotometry) were assessed. RESULTS: Mean arterial pressure (mmHg) increased only in norepinephrine-treated animals (from 73 [median; range 69 to 81] to 63 [60 to 68] in controls [P = 0.09] and from 83 [69 to 93] to 96 [86 to 108] in norepinephrine-treated animals [P = 0.019]). Cardiac index and systemic oxygen delivery (DO2) increased in both groups, but significantly more in the norepinephrine group (P < 0.03 for both). Cardiac index (ml/min per.kg) increased from 99 (range: 72 to 112) to 117 (110 to 232) in controls (P = 0.002), and from 107 (84 to 132) to 161 (147 to 340) in norepinephrine-treated animals (P = 0.001). DO2 (ml/min per.kg) increased from 13 (range: 11 to 15) to 16 (15 to 24) in controls (P = 0.028), and from 16 (12 to 19) to 29 (25 to 52) in norepinephrine-treated animals (P = 0.018). Systemic oxygen consumption (systemic VO2) increased in both groups (P < 0.05), whereas hepatosplanchnic flows, DO2 and VO2 remained stable. The hepatic lactate extraction ratio decreased in both groups (P = 0.05). Liver mitochondria complex I-dependent and II-dependent respiratory control ratios were increased in the norepinephrine group (complex I: 3.5 [range: 2.1 to 5.7] in controls versus 5.8 [4.8 to 6.4] in norepinephrine-treated animals [P = 0.015]; complex II: 3.1 [2.3 to 3.8] in controls versus 3.7 [3.3 to 4.6] in norepinephrine-treated animals [P = 0.09]). No differences were observed in citrate synthase activity. CONCLUSION: Norepinephrine treatment during endotoxaemia does not increase hepatosplanchnic flow, oxygen delivery or consumption, and does not improve the hepatic lactate extraction ratio. However, norepinephrine increases the liver mitochondria complex I-dependent and II-dependent respiratory control ratios. This effect was probably mediated by a direct effect of norepinephrine on liver cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fluid optimization is a major contributor to improved outcome in patients. Unfortunately, anesthesiologists are often in doubt whether an additional fluid bolus will improve the hemodynamics of the patient or not as excess fluid may even jeopardize the condition. This article discusses physiological concepts of liberal versus restrictive fluid management followed by a discussion on the respective capabilities of various monitors to predict fluid responsiveness. The parameter difference in pulse pressure (dPP), derived from heart-lung interaction in mechanically ventilated patients is discussed in detail. The dPP cutoff value of 13% to predict fluid responsiveness is presented together with several assessment techniques of dPP. Finally, confounding variables on dPP measurements, such as ventilation parameters, pneumoperitoneum and use of norepinephrine are also mentioned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most medical implants run on batteries, which require costly and tedious replacement or recharging. It is believed that micro-generators utilizing intracorporeal energy could solve these problems. However, such generators do not, at this time, meet the energy requirements of medical implants.This paper highlights some essential aspects of designing and implementing a power source that scavenges energy from arterial expansion and contraction to operate an implanted medical device. After evaluating various potentially viable transduction mechanisms, the fabricated prototype employs an electromagnetic transduction mechanism. The artery is inserted into a laboratory-fabricated flexible coil which is permitted to freely deform in a magnetic field. This work also investigates the effects of the arterial wall's material properties on energy harvesting potential. For that purpose, two types of arteries (Penrose X-ray tube, which behave elastically, and an artery of a Göttinger minipig, which behaves viscoelastically) were tested. No noticeable difference could be observed between these two cases. For the pig artery, average harvestable power was 42 nW. Moreover, peak power was 2.38 μW. Both values are higher than those of the current state of the art (6 nW/16 nW). A theoretical modelling of the prototype was developed and compared to the experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. In the field of information technology (IT) time pressure is common. Working with tight deadlines together on the same task increases the risk of social stressors referring to tensions and conflicts at work. Purpose. This field study tested both the association of time pressure and social stressors with blood pressure during work. Method. Seven employees – staff of a small IT enterprise – participated in repeated ambulatory blood pressure measurements over the course of one week. Time pressure and social stressors at work were assessed by questionnaire at the beginning of the study. Results. Multilevel regression analyses of 138 samples revealed higher levels of time pressure to be related to marginally significant increases in mean arterial blood pressure at noon and in the afternoon. In addition, higher levels of social stressors at work were significantly associated to elevated mean arterial pressure in the afternoon. Conclusion. Findings support the view that threats to the social self play an important role in occupational health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A successful pregnancy requires an accommodating environment. Salt and water availability are critical for plasma volume expansion. Any changes in sodium intake would alter aldosterone, a hormone previously described beneficial in pregnancy. To date, it remains ambiguous whether high aldosterone or high salt intake is preferable. We hypothesized that increased aldosterone is a rescue mechanism and appropriate salt availability is equally effective in maintaining a normotensive blood pressure (BP) phenotype in pregnancy. We compared normotensive pregnant women (n=31) throughout pregnancy with young healthy female individuals (n=31–62) and performed salt sensitivity testing within the first trimester. Suppression of urinary tetrahydro-aldosterone levels by salt intake as measured by gas chromatography–mass spectrometry and urinary sodium excretion corrected for creatinine, respectively, was shifted toward a higher salt intake in pregnancy (P<0.0001). In pregnancy, neither high urinary tetrahydro-aldosterone nor sodium excretion was correlated with higher BP. In contrast, in nonpregnant women, systolic BP rose with aldosterone (P<0.05). Testing the impact of salt on BP, we performed salt sensitivity testing in a final cohort of 19 pregnant and 24 nonpregnant women. On salt loading, 24-hour mean arterial pressure rose by 3.6±1.5 and dropped by –2.8±1.5 mm Hg favoring pregnant women (P<0.01; χ2=6.04; P<0.02). Our data suggest first that salt responsiveness of aldosterone is alleviated in conditions of pregnancy without causing aldosterone-induced hypertension. Second, salt seems to aid in BP lowering in pregnancy for reasons incompletely elucidated, yet involving renin suppression and potentially placental sensing mechanisms. Further research should identify susceptible individuals and clarify effector mechanisms.