38 resultados para low-heating-rate sintering

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-based localization techniques such as multilateration are favoured for positioning to wide-band signals. Applying the same techniques with narrow-band signals such as GSM is not so trivial. The process is challenged by the needs of synchronization accuracy and timestamp resolution both in the nanoseconds range. We propose approaches to deal with both challenges. On the one hand, we introduce a method to eliminate the negative effect of synchronization offset on time measurements. On the other hand, we propose timestamps with nanoseconds accuracy by using timing information from the signal processing chain. For a set of experiments, ranging from sub-urban to indoor environments, we show that our proposed approaches are able to improve the localization accuracy of TDOA approaches by several factors. We are even able to demonstrate errors as small as 10 meters for outdoor settings with narrow-band signals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Patients with ilio-femoral deep-vein thrombosis (DVT) are at high risk of developing the post-thrombotic syndrome (PTS). In comparison to anticoagulation therapy alone, extended venography-guided catheter-directed thrombolysis without routine stenting of venous stenosis in patients with ilio-femoral DVT is associated with an increased risk of bleeding and a moderate reduction of PTS. We performed a prospective single-centre study to investigate safety, patency and incidence of PTS in patients with acute ilio-femoral DVT treated with fixed-dose ultrasound-assisted catheter-directed thrombolysis (USAT; 20 mg rt-PA during 15 hours) followed by routing stenting of venous stenosis, defined as residual luminal narrowing >50%, absent antegrade flow, or presence of collateral flow at the site of suspected stenosis. A total of 87 patients (age 46 ± 21 years, 60% women) were included. At 15 hours, thrombolysis success ≥50% was achieved in 67 (77%) patients. Venous stenting (mean 1.9 ± 1.3 stents) was performed in 70 (80%) patients, with the common iliac vein as the most frequent stenting site (83%). One major (1%; 95% CI, 0-6%) and 6 minor bleedings (7%; 95%CI, 3-14%) occurred. Primary and secondary patency rates at 1 year were 87% (95% CI, 74-94%) and 96% (95% CI, 88-99%), respectively. At three months, 88% (95% CI, 78-94%) of patients were free from PTS according to the Villalta scale, with a similar rate at one year (94%, 95% CI, 81-99%). In conclusion, a fixed-dose USAT regimen followed by routine stenting of underlying venous stenosis in patients with ilio-femoral DVT was associated with a low bleeding rate, high patency rates, and a low incidence of PTS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Norcamphor (C7H10O) was subjected to plane strain simple shear in a see-through deformation rig at four different strain rate and temperature conditions. Two transient stages in the microfabric evolution to steady state are distinguished. The grain scale mechanisms associated with the microstructural and textural evolution vary with the applied temperature, strain rate and strain. In high-temperature-low-strain-rate experiments, computer integrated polarization microscopy reveals that the texture evolution is closely related to the crystallographic rotation paths and rotation rates of individual grains. High c-axis rotation rates at low to intermediate shear strains are related to the development of a symmetrical c-axis cross girdle by the end of the first transient stage (γ = 1.5 to 2). During the second transient stage (γ = 1.5 to 6), the cross girdle yields to an oblique c-axis single girdle as c-axis rotation rates decrease and the relative activity of grain boundary migration recrystallization increases. Steady state (γ > 8) is characterized by a stable end orientation of the sample texture and the cyclic growth, rotation and consumption of individual grains within the aggregate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mechanical thrombectomy in ischemic stroke is of increasing interest as it is a promising strategy for fast and efficient recanalization. Several thrombectomy devices have been introduced to the armentarium of mechanical thrombectomy. Currently, new devices are under development and are continuously added to the neurointerventional tool box. Each device advocated so far has a different design and mechanical properties in terms of thrombus-device interaction. Therefore, a systematic evaluation under standardized conditions in vivo of these new devices is needed. The purpose of this study was to evaluate the efficiency, thrombus-device interaction, and potential complications of the novel Phenox CRC for distal mechanical thrombectomy in vivo. The device was evaluated in an established animal model in the swine. Recanalization rate, thromboembolic events, vasospasm, and complications were assessed. Radiopaque thrombi (2 cm length) were used for the visualization of thrombus-device interaction during retrieval. The Phenox CRC (4 mm diameter) was assessed in 15 vessel occlusions. For every occlusion a maximum of 3 retrieval attempts were performed. Complete recanalization (TICI 3/TIMI 3) was achieved in 86.7% of vessel occlusions. In 66.7% (10/15), the first retrieval attempt was successful, and in 20% (3/15), the second attempt led to complete recanalization of the parent artery. In 2 cases (13.3%) thrombus retrieval was not successful (TICI 0/TIMI 0). In 1 case (6.7%) a minor embolic event occurred in a small side branch. No distal thromboembolic event was observed during the study. Thrombus-device interaction illustrated the entrapment of the thrombus by the microfilaments and the proximal cage of the device. No significant thrombus compression was observed. No vessel perforation, dissection, or fracture of the device occurred. In this small animal study, the Phenox CRC was a safe and effective device for mechanical thrombectomy. The unique design with a combination of microfilaments and proximal cage reduces thrombus compression with a consequently high recanalization and low complication rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In groves of ectomycorrhizal caesalpiniaceous species in the Atlantic coastal forest of Central Africa the dominant tree Microberlinia bisulcata, which is shade-intolerant as a seedling but highly light-responding as a sapling, shows very limited regeneration. M. bisulcata saplings were mapped in an 82.5-ha plot at Korup and found to be located significantly far (>40 m) away from adults, a result confirmed by direct testing in a second 56-ha plot. Sapling growth over 6 years, the distribution of newly emerging seedlings around adults, recruitment of saplings in a large opening and the outward extent of seedlings at the grove edge were also investigated. Two processes appear to have been operating: (1) a very strong and consistent restriction of the very numerous seedlings establishing after masting close to adults, and (2) a strong but highly spatially variable promotion of distant survivors by increased light from the deaths of large trees of species other than M. bisulcata (which itself has very low mortality rate). This leads to an apparent escape-from-adults effect. To maintain saplings in the shade between multiple short periods of release ectomycorrhizal connections to other co-occurring caesalp species may enable a rachet-type mechanism. The recorded sapling dynamics currently contribute an essential part of the long-term cycling of the groves. M. bisulcata is an interesting example of an important group of tropical trees, particularly in Africa, which are both highly light-demanding when young yet capable also of forming very large forest emergents. To more comprehensively explain tropical tree responses, the case is made for adding a new dimension to the trade-off concept of early tree light-response versus adult longevity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Where one or a few tree species reach local high abundance, different ecological factors may variously facilitate or hinder their regeneration. Plant pathogens are thought to be one of those possible agents which drive intraspecific density-dependent mortality of tree seedlings in tropical forests. Experimental evidence for this is scarce, however. In an African rain forest at Korup, we manipulated the density of recently established seedlings (~5–8 wk old; low vs. high-density) of two dominant species of contrasting recruitment potential, and altered their exposure to pathogens using a broad-spectrum fungicide. Seedling mortality of the abundantly recruiting subcanopy tree Oubanguia alata was strongly density-dependent after 7 mo, yet fungicide-treated seedlings had slightly higher mortality than controls. By contrast, seedling mortality of the poorly recruiting large canopy-emergent tree Microberlinia bisulcata was unaffected by density or fungicide. Ectomycorrhizal colonization of M. bisulcata was not affected by density or fungicide either. For O. alata, adverse effects of fungicide on its vesicular arbuscular mycorrhizas may have offset any possible benefit of pathogen removal. We tentatively conclude that fungal pathogens are not a likely major cause of density dependence in O. alata, or of early post-establishment mortality in M. bisulcata. They do not explain the latter's currently very low recruitment rate at Korup.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OPINION STATEMENT: • In acute spinal cord ischemia syndrome (ASCIS), treatment recommendations are derived from data of cerebral ischemic stroke, atherosclerotic vascular disease and acute spinal cord injury. Besides acute management, secondary prevention is of major importance. Pathologies affecting the aorta as well as underlying cerebrovascular conditions should be treated whenever possible.• ASCIS may occur after aortic surgery, less often after thoracic endovascular aortic repair (TEVAR). Protocols are proposed.• Acute spinal cord hemorrhage can be treated surgically and/or pharmacologically.• Symptomatic treatment in patients with a spinal cord lesion is of major importance. Depending on level and extension of the lesion, there is a risk for systemic and neurological complications, which may be life-threatening.• Each spinal vascular malformation is a unique lesion that needs an individualized treatment algorithm. In case of a symptomatic vascular malformation, endovascular intervention is the primary treatment option.• Spinal dural Arteriovenous fistula (AVF) may be treated endovascularly or surgically. If preoperative localization of the fistula is possible, surgery is feasible with a low complication rate. In comparison, endovascular approaches are less invasive.• Spinal AVM are rather treated endovascularly than surgically or in a stepwise multidisciplinary approach.• Symptomatic and exophytic spinal cavernous angiomas should be treated surgically. Deep spinal cavernous angiomas that are asymptomatic or only show mild symptoms can be observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Most adults infected with HIV achieve viral suppression within a year of starting combination antiretroviral therapy (cART). It is important to understand the risk of AIDS events or death for patients with a suppressed viral load. Methods and Findings Using data from the Collaboration of Observational HIV Epidemiological Research Europe (2010 merger), we assessed the risk of a new AIDS-defining event or death in successfully treated patients. We accumulated episodes of viral suppression for each patient while on cART, each episode beginning with the second of two consecutive plasma viral load measurements <50 copies/µl and ending with either a measurement >500 copies/µl, the first of two consecutive measurements between 50–500 copies/µl, cART interruption or administrative censoring. We used stratified multivariate Cox models to estimate the association between time updated CD4 cell count and a new AIDS event or death or death alone. 75,336 patients contributed 104,265 suppression episodes and were suppressed while on cART for a median 2.7 years. The mortality rate was 4.8 per 1,000 years of viral suppression. A higher CD4 cell count was always associated with a reduced risk of a new AIDS event or death; with a hazard ratio per 100 cells/µl (95% CI) of: 0.35 (0.30–0.40) for counts <200 cells/µl, 0.81 (0.71–0.92) for counts 200 to <350 cells/µl, 0.74 (0.66–0.83) for counts 350 to <500 cells/µl, and 0.96 (0.92–0.99) for counts ≥500 cells/µl. A higher CD4 cell count became even more beneficial over time for patients with CD4 cell counts <200 cells/µl. Conclusions Despite the low mortality rate, the risk of a new AIDS event or death follows a CD4 cell count gradient in patients with viral suppression. A higher CD4 cell count was associated with the greatest benefit for patients with a CD4 cell count <200 cells/µl but still some slight benefit for those with a CD4 cell count ≥500 cells/µl.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Mechanical thrombectomy is a promising new modality of interventional stroke treatment. The various devices differ with regard to where they apply force on the thrombus, taking a proximal approach such as aspiration devices or a distal approach such as basket-like devices. The study compares the in vivo effectiveness and thrombus-device interaction of these 2 approaches. METHODS: Angiography and embolization with a radioopaque whole blood thrombus was performed in 10 swine. Mechanical thrombectomy was performed in 20 cranial vessels using a proximal aspiration device (Vasco35) and a distal basket-like device (Catch) with and without proximal balloon occlusion. Fifty-six retrieval attempts were made. RESULTS: The proximal device allowed fast repeated application with a low risk of thromboembolic events (3%) and vasospasm, but it had a significantly lower success rate (39.4%) in retrieving thrombotic material than the distal device (DD) (82.6%; odds ratio, 7.3; 95% CI, 2.0 to 26.4). The compaction of the thrombus during retrieval with DD increased the risk of vessel wall irritation significantly (P<0.01) and complicated retrieval into the guiding catheter. The number of embolic events was significantly higher with DD (26%; odds ratio, 11.3; 95% CI, 1.35 to 101.6) unless proximal balloon occlusion was used. CONCLUSIONS: The proximal and the distal approaches to mechanical thrombectomy proved to be effective at achieving recanalization of cranial vessels. The proximal device is faster in application and allowed repeated attempts with a low complication rate. The DD is more successful at removing thrombotic material, but its method of application and attendant thrombus compaction increase the risk of thromboembolic events and vasospasms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spindle cell oncocytoma (SCO) is a recently described, rare neoplasm of the anterior pituitary. Clinically and radiologically simulating a non-functioning macroadenoma, its eponymous fusiform cells display a non-epithelial phenotype with conspicuous cytoplasmic accumulation of mitochondria. We report a case of SCO retrospectively identified in a biopsy specimen 16 years after transsphenoidal operation of a 48-year-old woman. Presenting symptoms were adynamia and transient decrease of visual acuity. Neuroimaging showed an isointense, enhancing, sellar-centered mass 1.8 cm in diameter without evidence of invasive growth. No postoperative adjuvant therapy was administered. The patient was left with panhypopituitarism, yet no recurrence was seen during follow-up. Initially diagnosed as a null cell adenoma of oncocytic type, repeat immunohistochemistry showed the characteristic coexpression of S100 protein, vimentin, and epithelial membrane antigen. Oncocytic granula stained intensely with antimitochondrial antibody 113-1, and were negative with the lysosomal marker CD68. Anterior pituitary hormones tested negative, and there was no evidence of neuroendocrine differentiation using antibodies to synaptophysin and chromogranin. Few cells stained for glial fibrillary acidic protein (GFAP). SCO has been proposed to represent a neoplasm of folliculo-stellate cells (FSCs). While the dynamic properties of the latter are incompletely characterized, and indeed no specific marker allows for their identification, overlapping features of SCO with look alikes, in particular pituicytoma, point to FSCs being a potential adult stem cell. The favorable outcome of the present case further argues for SCO to be considered a low-grade neoplasm. Moderate tumor size, lack of invasiveness, and low proliferation rate are likely predictors of benign behavior.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The Nobel Direct implant (Nobel Biocare AB, Göteborg, Sweden) was developed to minimize marginal bone resorption and to result in "soft tissue integration" for an optimized aesthetic outcome. However, conflicting results have been presented in the literature. The aim of this present study was to evaluate the clinical and microbiologic outcomes of Nobel Direct implants. MATERIALS AND METHODS: Ten partially edentulous subjects without evidence of active periodontitis (mean age 55 years) received 12 Nobel Direct implants. Implants were loaded with single crowns after a healing period of 3 to 6 months. Treatment outcomes were assessed at month 24. Routine clinical assessments, intraoral radiographs, and microbiologic samplings were made. Histologic analysis of one failing implant and chemical spectroscopy around three unused implants was performed. Paired Wilcoxon signed-rank test was used for the evaluation of bone loss; otherwise, descriptive analysis was performed. RESULTS: Implants were functionally loaded after 3 to 6 months. At 2 years, the mean bone loss of remaining implants was 2.0 mm (SD +/- 1.1 mm; range: 0.0-3.4 mm). Three out of 12 implants with an early mean bone loss >3 mm were lost. The surviving implants showed increasing bone loss between 6 and 24 months (p = .028). Only 3 out of the 12 implants were considered successful and showed bone loss of <1.7 mm after 2 years. High rates of pathogens, including Aggregatibacter actinomycetemcomitans, Fusobacterium spp., Porphyromonas gingivalis, Pseudomonas aeruginosa, and Tanerella forsythia, were found. Chemical spectroscopy revealed, despite the normal signals from Ti, O, and C, also peaks of P, F, S, N, and Ca. A normal histologic image of osseointegration was observed in the apical part of the retrieved implant. CONCLUSION: Radiographic evidence and 25% implant failures are indications of a low success rate. High counts and prevalence of significant pathogens were found at surviving implants. Although extensive bone loss had occurred in the coronal part, the apical portion of the implant showed some bone to implant integration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Prolonged sacral neuromodulation (SNM) testing is more reliable for accurate patient selection than the usual test period of 4-7 days. However, prolonged testing was suspected to result in a higher complication rate due to infection via the percutaneous passage of the extension wire. Therefore, we prospectively assessed the complications associated with prolonged tined lead testing. PATIENTS AND METHODS: A consecutive series of 44 patients who underwent prolonged tined lead testing for at least 14 days between May 2002 and April 2007 were evaluated. Complications during prolonged tined lead testing, during and after tined lead explantation and during follow-up after implantation of the implantable pulse generator (IPG) were registered prospectively. RESULTS: Four patients suffered from urgency-frequency syndrome, 13 from urge incontinence, 18 from non-obstructive chronic urinary retention and nine from chronic pelvic pain syndrome. The median test phase was 30 days (interquartile range [IQR] 21-36). Thirty-two of the 44 patients (73%) had successful prolonged tined lead testing and 31 of these (97%) underwent the implantation of the IPG. The median follow-up of the IPG implanted patients was 31 months (IQR 20-41). The complication rate was 5% (2/44) during prolonged tined lead testing and 16% (5/31) during follow-up of the IPG implanted patients, respectively. None of the complications could be attributed to prolonged testing. No infections were observed during the study period. CONCLUSIONS: This prospective, observational non-randomised study suggests prolonged SNM tined lead testing is a safe procedure. Based on the low complication rate and the increased reliability for accurate patient selection, this method is proposed as a possible standard test procedure, subject to confirmation by further randomised, controlled clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The exponential increase in cardioverter-defibrillator implantations has resulted in a need for safe implantations that do not require long waiting periods. We report intraoperative and follow-up results in 48 patients with ventricular tachyarrhythmias who underwent cardioverter-defibrillator implantation in the catheterization laboratory. Twenty-six (54%) patients had their first cardioverter-defibrillator implant (group 1), and 22 (46%) patients underwent pulse-generator replacement (group 2). In all patients, cardioverter-defibrillator implant or pulse-generator replacement was performed with the patient under general anesthesia. In 25 (96%) of 26 patients in group 1, cardioverter-defibrillator implantation was possible with a mean defibrillation threshold of 13 +/- 8 J. One patient had a defibrillation threshold of > 25 J, and therefore cardioverter-defibrillator implant was not achieved. This patient underwent epicardial device implantation 1 day later. Another patient in group 1 had vessel rupture (vena subclavia) intraoperatively. During a mean follow-up of 2 +/- 1 months, two patients died from congestive heart failure 2 and 4 months after device implantation. An infection occurred in one patient in group 2, 3 months after generator replacement. In conclusion, these data show that in the majority of patients cardioverter-defibrillator implantation in the catheterization laboratory is safe and has a low complication rate and therefore can generally be recommended.