7 resultados para loading test
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To gain better insight in the most current diagnosis and treatment practices for phenylketonuria (PKU) from a broad group of experts, a European PKU survey was performed. The questionnaire, consisting of 33 questions, was sent to 243 PKU professionals in 165 PKU centers in 23 European countries. The responses were compiled and descriptive analyses were performed. One hundred and one questionnaires were returned by 93/165 centers (56%) from 19/23 European countries (83%). The majority of respondents (77%) managed patients of all age groups and more than 90% of PKU teams included physicians or dieticians/nutritionists. The greatest variability existed especially in the definition of PKU phenotypes, therapeutic blood phenylalanine (Phe) target concentrations, and follow-up practices for PKU patients. The tetrahydrobiopterin (BH4; sapropterin) loading test was performed by 54% of respondents, of which 61% applied a single dose test (20mg/kg over 24h). BH4 was reported as a treatment option by 34%. This survey documents differences in diagnostic and treatment practices for PKU patients in European centers. In particular, recommendations for the treatment decision varied greatly between different European countries. There is an urgent need to pool long-term data in PKU registries in order to generate an evidence-based international guideline.
Resumo:
The aim of this study was to assess the prevalence of incomplete distal renal tubular acidosis (idRTA) in men with recurrent calcium nephrolithiasis and its potential impact on bone mineral density. We conducted a retrospective analysis of 150 consecutive, male idiopathic recurrent calcium stone formers (RCSFs), which had originally been referred to the tertiary care stone center of the University Hospital of Berne for further metabolic evaluation. All RCSFs had been maintained on a free-choice diet while collecting two 24-h urine samples and delivered second morning urine samples after 12 h fasting. Among 12 RCSFs with a fasting urine pH >5.8, a modified 3-day ammonium chloride loading test identified idRTA in 10 patients (urine pH >5.32, idRTA group). We matched to each idRTA subject 5 control subjects from the 150 RCSFs, primary by BMI and then by age, i.e., 50 patients, without any acidification defect (non-RTA group) for comparative biochemistry and dual energy X-ray absorptiometry (DEXA) analyses. The prevalence of primary idRTA among RCSFs was 6.7% (10/150). Patients with idRTA had significantly higher 2-h fasting and 24-h urine pH (2-h urine pH: 6.6 ± 0.4 vs. 5.2 ± 0.1, p = 0.001; 24-h urine pH: 6.1 ± 0.2 vs. 5.3 ± 0.3, p = 0.001), 24-h urinary calcium excretion (7.70 ± 1.75 vs. 5.69 ± 1.73 mmol/d, p = 0.02), but significantly lower 24-h urinary urea excretion (323 ± 53 vs. 399 ± 114 mmol/d, p = 0.01), urinary citrate levels (2.32 ± 0.82 vs. 3.01 ± 0.72 mmol/d, p = 0.04) and renal phosphate threshold normalized for the glomerular filtration rate (TmPO(4)/GFR: 0.66 ± 0.17 vs. 0.82 ± 0.21, p = 0.03) compared to non-RTA patients. No significant difference in bone mineral density (BMD) was found between idRTA and non-RTA patients for the lumbar spine (LS BMD (g/cm(2)): 1.046 ± 0.245 SD vs. 1.005 ± 0.119 SD, p = 0.42) or femoral neck (FN BMD (g/cm(2)): 0.830 ± 0.135 SD vs. 0.852 ± 0.127 SD). Thus, idRTA occurs in 1 in 15 male RCSFs and should be sought in all recurrent calcium nephrolithiasis patients. Bone mineral density, however, does not appear to be significantly affected by idRTA.
Resumo:
It is generally agreed that the mechanical environment of intervertebral disc cells plays an important role in maintaining a balanced matrix metabolism. The precise mechanism by which the signals are transduced into the cells is poorly understood. Osmotic changes in the extracellular matrix (ECM) are thought to be involved. Current in-vitro studies on this topic are mostly short-term and show conflicting data on the reaction of disc cells subjected to osmotic changes which is partially due to the heterogenous and often substantially-reduced culture systems. The aim of the study was therefore to investigate the effects of cyclic osmotic loading for 4 weeks on metabolism and matrix gene expression in a full-organ intervertebral disc culture system. Intervertebral disc/endplate units were isolated from New Zealand White Rabbits and cultured either in iso-osmotic media (335 mosmol/kg) or were diurnally exposed for 8 hours to hyper-osmotic conditions (485 mosmol/kg). Cell viability, metabolic activity, matrix composition and matrix gene expression profile (collagen types I/II and aggrecan) were monitored using Live/Dead cell viability assay, tetrazolium reduction test (WST 8), proteoglycan and DNA quantification assays and quantitative PCR. The results show that diurnal osmotic stimulation did not have significant effects on proteoglycan content, cellularity and disc cell viability after 28 days in culture. However, hyperosmolarity caused increased cell death in the early culture phase and counteracted up-regulation of type I collagen gene expression in nucleus and annulus cells. Moreover, the initially decreased cellular dehydrogenase activity recovered with osmotic stimulation after 4 weeks and aggrecan gene down-regulation was delayed, although the latter was not significant according to our statistical criteria. In contrast, collagen type II did not respond to the osmotic changes and was down-regulated in both groups. In conclusion, diurnal hyper-osmotic stimulation of a whole-organ disc/endplate culture partially inhibits a matrix gene expression profile as encountered in degenerative disc disease and counteracts cellular metabolic hypo-activity.
Resumo:
PURPOSE: The aim of the present clinical trial was to evaluate the 12-month success rate of titanium dental implants placed in the posterior mandible and immediately loaded with 3-unit fixed partial dentures. MATERIALS AND METHODS: Patients with missing mandibular premolars and molars were enrolled in this study. To be included in the study, the implants had to show good primary stability. Implant stability was measured with resonance frequency analysis using the Osstell device (Integration Diagnostics). Implants were included in the study when the stability quotient (ISQ) exceeded 62. Clinical measurements, such as width of keratinized tissue, ISQ, and radiographic assessment of peri-implant bone crest levels, were performed at baseline and at the 12-month follow-up. The comparison between the baseline and the 12-month visits was performed with the Student t test for paired data (statistically significant at a level of alpha = 0.05). RESULTS: Forty implants with a sandblasted, large grit, acid-etched (SLA) surface (Straumann) were placed in 20 patients. At 12 months, only 1 implant had been lost because of an acute infection. The remaining 39 implants were successful, resulting in a 1-year success rate of 97.5%. Neither peri-implant bone levels, measured radiographically, nor implant stability changed significantly from baseline to the 12-month follow-up (P > .05). DISCUSSION: The immediate functional loading of implants placed in this case series study resulted in a satisfactory success rate. CONCLUSION: The findings from this clinical study showed that the placement of SLA transmucosal implants in the mandibular area and their immediate loading with 3-unit fixed partial dentures may be a safe and successful procedure.
Resumo:
OBJECTIVES: The aim of the present split-mouth study is to assess the peri-implant conditions around early-loaded sandblasted and acid-etched (SLA) implants, 5 years after abutment connection and to compare, in the same patients, the results obtained with a standard protocol using identical implants with a TPS surface. MATERIAL AND METHODS: Surgical procedure was performed by the same operator and was identical at test (SLA) and control (TPS) sites, in 32 healthy patients. Abutment connection was carried out at 35 N cm 6 weeks postsurgery for test sites and 12 weeks for the controls. Patients were seen regularly, for control and professional cleaning. At 60 months, clinical measures and radiographic bone changes were recorded by the same operator, blind to the type of surface of the implant, on 27 patients, as five patients were lost to follow-up. RESULTS: A total number of 106 implants were examined. No implant was lost. No significant differences were found with respect to the presence of plaque [modified plaque index (mPI) 0.27+/-0.56 vs. 0.32+/-0.54], bleeding on probing (29% vs. 32%), mean pocket depth (3.2+/-1 vs. 3.2+/-1 mm) or mean marginal bone loss (0.32+/-1.04 vs. 0.44+/-1.12 mm) between test and control. Four implants that presented 'spinning' at the time of abutment connection presented no significant differences from the rest of the test sites. CONCLUSION: The results of this prospective study confirm that SLA implants, under defined conditions, are suitable for early loading at 6 weeks in both the mandible and the maxilla. Limited implant spinning, occasionally found at abutment connection, produces no detrimental effect on the clinical outcome when properly handled.
Resumo:
PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.
Resumo:
INTRODUCTION An accurate description of the biomechanical behavior of the spine is crucial for the planning of scoliotic surgical correction as well as for the understanding of degenerative spine disorders. The current clinical assessments of spinal mechanics such as side-bending or fulcrum-bending tests rely on the displacement of the spine observed during motion of the patient. Since these tests focused solely on the spinal kinematics without considering mechanical loads, no quantification of the mechanical flexibility of the spine can be provided. METHODS A spinal suspension test (SST) has been developed to simultaneously monitor the force applied on the spine and the induced vertebral displacements. The system relies on cervical elevation of the patient and orthogonal radiographic images are used to measure the position of the vertebras. The system has been used to quantify the spinal flexibility on five AIS patients. RESULTS Based on the SST, the overall spinal flexibility varied between 0.3 °/Nm for the patient with the stiffer curve and 2 °/Nm for the less rigid curve. A linear correlation was observed between the overall spinal flexibility and the change in Cobb angle. In addition, the segmental flexibility calculated for five segments around the apex was 0.13 ± 0.07 °/Nm, which is similar to intra-operative stiffness measurements previously published. CONCLUSIONS In summary, the SST seems suitable to provide pre-operative information on the complex functional behavior and stiffness of spinal segments under physiological loading conditions. Such tools will become increasingly important in the future due to the ever-increasing complexity of the surgical instrumentation and procedures.