13 resultados para lithium composed

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oncocytomas are defined as tumors containing in excess of 50% large mitochondrion-rich cells, irrespective of histogenesis and dignity. Along the central neuraxis, oncocytomas are distinctly uncommon but relevant to the differential diagnosis of neoplasia marked by prominent cytoplasmic granularity. We describe an anaplastic ependymoma (WHO grade III) with a prevailing oncocytic component that was surgically resected from the right fronto-insular region of a 43-year-old female. Preoperative imaging showed a fairly circumscribed, partly cystic, contrast-enhancing mass of 2 cm × 2 cm × 1.7 cm. Histology revealed a biphasic neoplasm wherein conventional ependymal features coexisted with plump epithelioid cells replete with brightly eosinophilic granules. Whereas both components displayed an overtly ependymal immunophenotype, including positivity for S100 protein and GFAP, as well as "dot-like" staining for EMA, the oncocytic population also tended to intensely react with the antimitochondrial antibody 113-1. Conversely, failure to bind CD68 indicated absence of significant lysosomal storage. Negative reactions for both pan-cytokeratin (MNF 116) and low molecular weight cytokeratin (CAM 5.2), as well as synaptophysin and thyroglobulin, further assisted in ruling out metastatic carcinoma. In addition to confirming the presence of "zipper-like" intercellular junctions and microvillus-bearing cytoplasmic microlumina, electron microscopy allowed for the pervasive accumulation of mitochondria in tumor cells to be directly visualized. A previously not documented variant, oncocytic ependymoma, is felt to add a reasonably relevant novel item to the differential diagnosis of granule-bearing central nervous system neoplasia, in particular oncocytic meningioma, granular cell astrocytoma, as well as metastatic deposits by oncocytic malignancies from extracranial sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HeLa cells expressing wild-type connexin43, connexin40 or connexin45 and connexins fused with a V5/6-His tag to the carboxyl terminus (CT) domain (Cx43-tag, Cx40-tag, Cx45-tag) were used to study connexin expression and the electrical properties of gap junction channels. Immunoblots and immunolabeling indicated that tagged connexins are synthesized and targeted to gap junctions in a similar manner to their wild-type counterparts. Voltage-clamp experiments on cell pairs revealed that tagged connexins form functional channels. Comparison of multichannel and single-channel conductances indicates that tagging reduces the number of operational channels, implying interference with hemichannel trafficking, docking and/or channel opening. Tagging provoked connexin-specific effects on multichannel and single-channel properties. The Cx43-tag was most affected and the Cx45-tag, least. The modifications included (1) V j-sensitive gating of I j (V j, gap junction voltage; I j, gap junction current), (2) contribution and (3) kinetics of I j deactivation and (4) single-channel conductance. The first three reflect alterations of fast V j gating. Hence, they may be caused by structural and/or electrical changes on the CT that interact with domains of the amino terminus and cytoplasmic loop. The fourth reflects alterations of the ion-conducting pathway. Conceivably, mutations at sites remote from the channel pore, e.g., 6-His-tagged CT, affect protein conformation and thus modify channel properties indirectly. Hence, V5/6-His tagging of connexins is a useful tool for expression studies in vivo. However, it should not be ignored that it introduces connexin-dependent changes in both expression level and electrophysiological properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate whether equine serum amyloid A (SAA) concentrations could be reliably measured in plasma with a turbidimetric immunoassay previously validated for equine SAA concentrations in serum. Paired serum and lithium-heparin samples obtained from 40 horses were evaluated. No difference was found in SAA concentrations between serum and plasma using a paired t test (P=0.48). The correlation between paired samples was 0.97 (Spearman's rank P<0.0001; 95% confidence interval 0.95-0.99). Passing-Bablok regression analyses revealed no differences between paired samples. Bland-Altman plots revealed a positive bias in plasma compared to serum but the difference was not considered clinically significant. The results indicate that lithium-heparin plasma samples are suitable for measurement of equine SAA using this method. Use of either serum or plasma allows for greater flexibility when it comes to sample collection although care should be taken when comparing data between measurements from different sample types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiac output (CO) measurement with lithium dilution (COLD) has not been fully validated in sheep using precise ultrasonic flow probe technology (COUFP). Sheep generate important cardiovascular research models and the use of COLD has become more popular in experimental settings. METHODS: Ultrasonic transit-time perivascular flow probes were surgically implanted on the pulmonary artery of 13 sheep. Paired COLD readings were taken at six time points, before and after implantation of a left ventricular assist device (LVAD) and compared with COUFP recorded just after lithium injection. RESULTS: The mean COLD was 5.7 litre min(-1) (range 3.8-9.6 litre min(-1)) and mean COUFP 5.9 litre min(-1) (range 4.0-9.2 litre min(-1)). The bias (standard deviation) was 0.3 (1.0) litre min(-1) [5.1 (16.9)%] and limits of agreement (LOA) were -1.7 to 2.3 litre min(-1) (-28.8 to 39.0%) with a percentage error (PE) of 34.4%. Data to assess trending [rate (95% confidence intervals)] included a 78 (62-93)% concordance rate in the four-quadrant plot (n=27). In the half moon polar plot (n=19), the mean polar angle was +5°, the radial LOA were -49 to +35° and 68 (47-89)% of data points fell within 22.5° of the mean polar angle. Both tests indicated moderate to poor trending ability. CONCLUSION: COLD is not precise when evaluated against COUFP in sheep based on the statistical criteria set, but the results are comparable with previously published animal studies. KEYWORDS:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pneumococcal meningitis is associated with high morbidity and mortality rates. Brain damage caused by this disease is characterized by apoptosis in the hippocampal dentate gyrus, a morphological correlate of learning deficits in experimental paradigms. The mood stabilizer lithium has previously been found to attenuate brain damage in ischemic and inflammatory diseases of the brain. An infant rat model of pneumococcal meningitis was used to investigate the neuroprotective and neuroregenerative potential of lithium. To assess an effect on the acute disease, LiCl was administered starting five days prior to intracisternal infection with live Streptococcus pneumoniae. Clinical parameters were recorded, cerebrospinal fluid (CSF) was sampled, and the animals were sacrificed 42 hours after infection to harvest the brain and serum. Cryosections of the brains were stained for Nissl substance to quantify brain injury. Hippocampal gene expression of Bcl-2, Bax, p53, and BDNF was analyzed. Lithium concentrations were measured in serum and CSF. The effect of chronic lithium treatment on spatial memory function and cell survival in the dentate gyrus was evaluated in a Morris water maze and by quantification of BrdU incorporation after LiCl treatment during 3 weeks following infection. In the hippocampus, LiCl significantly reduced apoptosis and gene expression of Bax and p53 while it increased expression of Bcl-2. IL-10, MCP-1, and TNF were significantly increased in animals treated with LiCl compared to NaCl. Chronic LiCl treatment improved spatial memory in infected animals. The mood stabilizer lithium may thus be a therapeutic alternative to attenuate neurofunctional deficits as a result of pneumococcal meningitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lithium abundances and isotope compositions are reported for a suite of martian meteorites that span the range of petrological and geochemical types recognized to date for Mars. Samples include twenty-one bulk-rock enriched, intermediate and depleted shergottites, six nakhlites, two chassignites, the orthopyroxenite Allan Hills (ALH) 84001 and the polymict breccia Northwest Africa (NWA) 7034. Shergottites unaffected by terrestrial weathering exhibit a range in δ7Li from 2.1 to 6.2‰, similar to that reported for pristine terrestrial peridotites and unaltered mid-ocean ridge and ocean island basalts. Two chassignites have δ7Li values (4.0‰) intermediate to the shergottite range, and combined, these meteorites provide the most robust current constraints on δ7Li of the martian mantle. The polymict breccia NWA 7034 has the lowest δ7Li (−0.2‰) of all terrestrially unaltered martian meteorites measured to date and may represent an isotopically light surface end-member. The new data for NWA 7034 imply that martian crustal surface materials had both a lighter Li isotope composition and elevated Li abundance compared with their associated mantle. These findings are supported by Li data for olivine-phyric shergotitte NWA 1068, a black glass phase isolated from the Tissint meteorite fall, and some nakhlites, which all show evidence for assimilation of a low-δ7Li crustal component. The range in δ7Li for nakhlites (1.8 to 5.2‰), and co-variations with chlorine abundance, suggests crustal contamination by Cl-rich brines. The differences in Li isotope composition and abundance between the martian mantle and estimated crust are not as large as the fractionations observed for terrestrial continental crust and mantle, suggesting a difference in the styles of alteration and weathering between water-dominated processes on Earth versus possibly Cl–S-rich brines on Mars. Using high-MgO shergottites (>15 wt.% MgO) it is possible to estimate the δ7Li of Bulk Silicate Mars (BSM) to be 4.2 ± 0.9‰ (2σ). This value is at the higher end of estimates for the Bulk Silicate Earth (BSE; 3.5 ± 1.0‰, 2σ), but overlaps within uncertainty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.