12 resultados para laser shock processing (LSP)

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The African trypanosome, Trypanosoma brucei, has been used as a model to study the biosynthesis of GPI (glycosylphosphatidylinositol) anchors. In mammalian (bloodstream)-form parasites, diacyl-type GPI precursors are remodelled in their lipid moieties before attachment to variant surface glycoproteins. In contrast, the GPI precursors of insect (procyclic)-form parasites, consisting of lyso-(acyl)PI (inositol-acylated acyl-lyso-phosphatidylinositol) species, remain unaltered before protein attachment. By using a combination of metabolic labelling, cell-free assays and complementary MS analyses, we show in the present study that GPI-anchored glycoconjugates in T. congolense procyclic forms initially receive tri-acylated GPI precursors, which are subsequently de-acylated either at the glycerol backbone or on the inositol ring. Chemical and enzymatic treatments of [3H]myristate-labelled lipids in combination with ESI-MS/MS (electrospray ionization-tandem MS) and MALDI-QIT-TOF-MS3 (matrix-assisted laser-desorption ionization-quadrupole ion trap-time-of-flight MS) analyses indicate that the structure of the lipid moieties of steady-state GPI lipids from T. congolense procyclic forms consist of a mixture of lyso-(acyl)PI, diacyl-PI and diacyl-(acyl)PI species. Interestingly, some of these species are myristoylated at the sn-2 position. To our knowledge, this is the first demonstration of lipid remodelling at the level of protein- or polysaccharide-linked GPI anchors in procyclic-form trypanosomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Vasopressin has been shown to increase blood pressure in catecholamine-resistant septic shock. The aim of this study was to measure the effects of low-dose vasopressin on regional (hepato-splanchnic and renal) and microcirculatory (liver, pancreas, and kidney) blood flow in septic shock. METHODS: Thirty-two pigs were anesthetized, mechanically ventilated, and randomly assigned to one of four groups (n = 8 in each). Group S (sepsis) and group SV (sepsis/vasopressin) were exposed to fecal peritonitis. Group C and group V were non-septic controls. After 240 minutes, both septic groups were resuscitated with intravenous fluids. After 300 minutes, groups V and SV received intravenous vasopressin 0.06 IU/kg per hour. Regional blood flow was measured in the hepatic and renal arteries, the portal vein, and the celiac trunk by means of ultrasonic transit time flowmetry. Microcirculatory blood flow was measured in the liver, kidney, and pancreas by means of laser Doppler flowmetry. RESULTS: In septic shock, vasopressin markedly decreased blood flow in the portal vein, by 58% after 1 hour and by 45% after 3 hours (p < 0.01), whereas flow remained virtually unchanged in the hepatic artery and increased in the celiac trunk. Microcirculatory blood flow decreased in the pancreas by 45% (p < 0.01) and in the kidney by 16% (p < 0.01) but remained unchanged in the liver. CONCLUSION: Vasopressin caused marked redistribution of splanchnic regional and microcirculatory blood flow, including a significant decrease in portal, pancreatic, and renal blood flows, whereas hepatic artery flow remained virtually unchanged. This study also showed that increased urine output does not necessarily reflect increased renal blood flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Vasopressin increases arterial pressure in septic shock even when alpha-adrenergic agonists fail. The authors studied the effects of vasopressin on microcirculatory blood flow in the entire gastrointestinal tract in anesthetized pigs during early septic shock. METHODS: Thirty-two pigs were intravenously anesthetized, mechanically ventilated, and randomly assigned to one of four groups (n=8 in each; full factorial design). Group S (sepsis) and group SV (sepsis-vasopressin) were made septic by fecal peritonitis. Group C and group V were nonseptic control groups. After 300 min, group V and group SV received intravenous infusion of 0.06 U.kg.h vasopressin. In all groups, cardiac index and superior mesenteric artery flow were measured. Microcirculatory blood flow was recorded with laser Doppler flowmetry in both mucosa and muscularis of the stomach, jejunum, and colon. RESULTS: While vasopressin significantly increased arterial pressure in group SV (P<0.05), superior mesenteric artery flow decreased by 51+/-16% (P<0.05). Systemic and mesenteric oxygen delivery and consumption decreased and oxygen extraction increased in the SV group. Effects on the microcirculation were very heterogeneous; flow decreased in the stomach mucosa (by 23+/-10%; P<0.05), in the stomach muscularis (by 48+/-16%; P<0.05), and in the jejunal mucosa (by 27+/-9%; P<0.05), whereas no significant changes were seen in the colon. CONCLUSION: Vasopressin decreased regional flow in the superior mesenteric artery and microcirculatory blood flow in the upper gastrointestinal tract. This reduction in flow and a concomitant increase in the jejunal mucosa-to-arterial carbon dioxide gap suggest compromised mucosal blood flow in the upper gastrointestinal tract in septic pigs receiving low-dose vasopressin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Volume resuscitation is one of the primary therapeutic goals in hemorrhagic shock, but data on microcirculatory effects of different colloidal fluid resuscitation regimen are sparse. We investigated sublingual mucosal microcirculatory parameters during hemorrhage and after fluid resuscitation with gelatin, hydroxyethyl starch, or hypertonic saline and hydroxyethyl starch in pigs. METHODS: To induce hemorrhagic shock, 60% of calculated blood volume was withdrawn. Microvascular blood flow was assessed by laser Doppler velocimetry. Microcirculatory hemoglobin oxygen saturation was measured with a tissue reflectance spectrophotometry, and side darkfield imaging was used to visualize the microcirculation and to quantify the flow quality. Systemic hemodynamic variables, systemic acid base and blood gas variables, and lactate measurements were recorded. Measurements were performed at baseline, after hemorrhage, and after fluid resuscitation with a fixed volume regimen. RESULTS: Systemic hemodynamic parameters returned or even exceeded to baseline values in all three groups after fluid resuscitation, but showed significantly higher filling pressures and cardiac output values in animals treated with isotonic colloids. Microcirculatory parameters determined in gelatin and hydroxyethyl starch resuscitated animals, and almost all parameters except microvascular hemoglobin oxygen saturation in animals treated with hypertonic saline and hydroxyethyl starch, were restored after treatment. DISCUSSION: Hemorrhaged pigs can be hemodynamically stabilized with either isotonic or hypertonic colloidal fluids. The main finding is an adequate restoration of sublingual microcirculatory blood flow and flow quality in all three study groups, but only gelatin and hydroxyethyl starch improved microvascular hemoglobin oxygen saturation, indicating some inadequate oxygen supply/demand ratio maybe due to a better restoration of systemic hemodynamics in isotonic colloidal resuscitated animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a derivation and, based on it, an extension of a model originally proposed by V.G. Niziev to describe continuous wave laser cutting of metals. Starting from a local energy balance and by incorporating heat removal through heat conduction to the bulk material, we find a differential equation for the cutting profile. This equation is solved numerically and yields, besides the cutting profiles, the maximum cutting speed, the absorptivity profiles, and other relevant quantities. Our main goal is to demonstrate the model’s capability to explain some of the experimentally observed differences between laser cutting at around 1 and 10 μm wavelengths. To compare our numerical results to experimental observations, we perform simulations for exactly the same material and laser beam parameters as those used in a recent comparative experimental study. Generally, we find good agreement between theoretical and experimental results and show that the main differences between laser cutting with 1- and 10-μm beams arise from the different absorptivity profiles and absorbed intensities. Especially the latter suggests that the energy transfer, and thus the laser cutting process, is more efficient in the case of laser cutting with 1-μm beams.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laser pulses are largely used for processing and analysis of materials and in particular for nano-particle synthesis. This paper addresses fundamentals of the generation of nano-materials following specific thermodynamic paths of the irradiated material. Computer simulations using the hydro code MULTI and the SESAME equation of state have been performed to follow the dynamics of a target initially heated by a short laser pulse over a distance comparable to the metal skin depth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We process 20 years of SLR observations to GPS and GLONASS satellites using the reprocessed 3-day and 1-day microwave orbits provided by the Center for Orbit Determination in Europe (CODE) for the period 1994-2013. We study the dependency of the SLR residuals on the type, size, and a number of corner cubes in satellite laser reflector arrays (LRA). We show that the mean SLR residuals and the RMS of residuals depend on the coating of LRA and the block or type of GNSS satellites. The SLR mean residuals are also a function of the equipment used at SLR stations including detector types and detecting modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Satellite laser ranging (SLR) to the satellites of the global navigation satellite systems (GNSS) provides substantial and valuable information about the accuracy and quality of GNSS orbits and allows for the SLR-GNSS co-location in space. In the framework of the NAVSTAR-SLR experiment two GPS satellites of Block-IIA were equipped with laser retroreflector arrays (LRAs), whereas all satellites of the GLONASS system are equipped with LRAs in an operational mode. We summarize the outcome of the NAVSTAR-SLR experiment by processing 20 years of SLR observations to GPS and 12 years of SLR observations to GLONASS satellites using the reprocessed microwave orbits provided by the center for orbit determination in Europe (CODE). The dependency of the SLR residuals on the size, shape, and number of corner cubes in LRAs is studied. We show that the mean SLR residuals and the RMS of residuals depend on the coating of the LRAs and the block or type of GNSS satellites. The SLR mean residuals are also a function of the equipment used at SLR stations including the single-photon and multi-photon detection modes. We also show that the SLR observations to GNSS satellites are important to validate GNSS orbits and to assess deficiencies in the solar radiation pressure models. We found that the satellite signature effect, which is defined as a spread of optical pulse signals due to reflection from multiple reflectors, causes the variations of mean SLR residuals of up to 15 mm between the observations at nadir angles of 0∘ and 14∘. in case of multi-photon SLR stations. For single-photon SLR stations this effect does not exceed 1 mm. When using the new empirical CODE orbit model (ECOM), the SLR mean residual falls into the range 0.1–1.8 mm for high-performing single-photon SLR stations observing GLONASS-M satellites with uncoated corner cubes. For best-performing multi-photon stations the mean SLR residuals are between −12.2 and −25.6 mm due to the satellite signature effect.