14 resultados para laboratory method
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
This study evaluated the correlation between three strip-type, colorimetric tests and two laboratory methods with respect to the analysis of salivary buffering. The strip-type tests were saliva-check buffer, Dentobuff strip and CRT(®) Buffer test. The laboratory methods included Ericsson's laboratory method and a monotone acid/base titration to create a reference scale for the salivary titratable acidity. Additionally, defined buffer solutions were prepared and tested to simulate the carbonate, phosphate and protein buffer systems of saliva. The correlation between the methods was analysed by the Spearman's rank test. Disagreement was detected between buffering capacity values obtained with three strip-type tests that was more pronounced in case of saliva samples with medium and low buffering capacities. All strip-type tests were able to assign the hydrogencarbonate, di-hydrogenphosphate and 0.1% protein buffer solutions to the correct buffer categories. However, at 0.6% total protein concentrations, none of the test systems worked accurately. Improvements are necessary for strip-type tests because of certain disagreement with the Ericsson's laboratory method and dependence on the protein content of saliva.
Resumo:
There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.
Resumo:
A total of 2538 quarter milk samples from 638 lactating dairy cows from 47 farms in the canton of Bern, Switzerland, were investigated for streptococci. A novel, simple and inexpensive laboratory method was used for the differentiation of Streptococcus species, and a risk factor analysis was carried out. The prevalence in the quarter milk samples was 0.2 per cent for Streptococcus agalactiae, 1.3 per cent for Streptococcus uberis, 1.3 per cent for Streptococcus dysgalactiae, 0.1 per cent for Enterococcus species and 2.9 per cent for minor Streptococcus species (designated Streptococcus-Lactococcus-Enterococcus [SLE] group). Based on the somatic cell count (SCC), S uberis and S dysgalactiae were classified as 'major' pathogens and the bacteria in the SLE group as 'minor' pathogens. For S uberis, S dysgalactiae and bacteria in the SLE group, the most significant risk factor was an intramammary infection (IMI) of a neighbouring quarter by the same pathogen. Other significant risk factors for S uberis infection were a positive California Mastitis Test (CMT) result and a SCC of more than 100,000 cells/ml. Significant risk factors for IMI with S dysgalactiae were a positive CMT result, teat injury and palpable abnormalities in the udder. Infection with bacteria in the SLE group was significantly associated with a SCC of more than 100,000 cells/ml, a lactation number of more than 2, the right rear quarter (as the location of infection) and a positive CMT result.
Multicentre evaluation of a new point-of-care test for the determination of NT-proBNP in whole blood
Resumo:
BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.
Resumo:
A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.
Resumo:
OBJECTIVE: Measuring peritoneal lactate concentrations could be useful for detecting splanchnic hypoperfusion. The aims of this study were to evaluate the properties of a new membrane-based microdialyzer in vitro and to assess the ability of the dialyzer to detect a clinically relevant decrease in splanchnic blood flow in vivo. DESIGN: A membrane-based microdialyzer was first validated in vitro. The same device was tested afterward in a randomized, controlled animal experiment. SETTING: University experimental research laboratory. SUBJECTS: Twenty-four Landrace pigs of both genders. INTERVENTIONS: In vitro: Membrane microdialyzers were kept in warmed sodium lactate baths with lactate concentrations between 2 and 8 mmol/L for 10-120 mins, and microdialysis lactate concentrations were measured repeatedly (210 measurements). In vivo: An extracorporeal shunt with blood reservoir and roller pump was inserted between the proximal and distal abdominal aorta, and a microdialyzer was inserted intraperitoneally. In 12 animals, total splanchnic blood flow (measured by transit time ultrasound) was reduced by a median 43% (range, 13% to 72%) by activating the shunt; 12 animals served as controls. MEASUREMENTS AND MAIN RESULTS: In vitro: The fractional lactate recovery was 0.59 (0.32-0.83) after 60 mins and 0.82 (0.71-0.87) after 90 mins, with no further increase thereafter. At 60 and 90 mins, the fractional recovery was independent of the lactate concentration. In vivo: Abdominal blood flow reduction resulted in an increase in peritoneal microdialysis lactate concentration from 1.7 (0.3-3.8) mmol/L to 2.8 (1.3-6.2) mmol/L (p = .006). At the same time, mesenteric venous-arterial lactate gradient increased from 0.1 (-0.2-0.8) mmol/L to 0.3 (-0.3 -1.8) mmol/L (p = .032), and mesenteric venous-arterial Pco2 gradients increased from 12 (8-19) torr to 21 (11-54) torr (p = .005). CONCLUSIONS: Peritoneal membrane microdialysis provides a method for the assessment of splanchnic ischemia, with potential for clinical application.
Resumo:
PURPOSE: A microangiographical technique is described, which allows visualization of small and capillary blood vessels and quantification of fasciocutaneous blood vessels by means of digital computer analysis in very small laboratory animals. MATERIALS AND METHODS: The left carotid artery of 20 nu/nu mice was cannulated (26 gauge) and a mixture of gelatin, bariumsulfate, and green ink was injected according to standardized protocol. Fasciocutaneous blood vessels were visualized by digital mammography and analyzed for vessel length and vessel surface area as standardized units [SU] by computer program. RESULTS: With the described microangiography method, fasciocutaneous blood vessels down to capillary size level can be clearly visualized. Regions of interest (ROIs) can be defined and the containing vascular network quantified. Comparable results may be obtained by calculating the microvascular area index (MAI) and the microvascular length index (MLI), related to the ROIs size. Identical ROIs showed a high reproducibility for measured [SU] < 0.01 +/- 0.0012%. CONCLUSION: Combining microsurgical techniques, pharmacological knowledge, and modern digital image technology, we were able to visualize small and capillary blood vessels even in small laboratory animals. By using our own computer analytical program, quantification of vessels was reliable, highly reproducible, and fast.
Resumo:
This study compared the results of reverse transcription-polymerase chain reaction (RT-PCR) and traditional virus isolation on cell culture in detection of viral haemorrhagic septicaemia virus (VHSV) and infectious haematopoietic necrosis virus (IHNV). RT-PCR was used for 172 tissue sample pools (total of 859 fish) originating from a field survey on the occurrence of VHSV and IHNV in farmed and wild salmonids in Switzerland. These samples represented all sites with fish that were either identified as virus-positive by means of virus isolation (three sites, four positive tissue sample pools) and/or demonstrated positive anti-VHSV-antibody titres (83 sites, 121 positive blood samples) in a serum plaque neutralization test (SPNT). The RT-PCR technique confirmed the four VHSV-positive tissue sample pools detected by virus isolation and additionally identified one VHSV-positive sample that showed positive anti-VHSV-AB titres, but was negative in virus isolation. With IHNV, RT-PCR detected two positive samples not identified by virus isolation while in these fish the SPNT result had been questionable. One of the IHNV-positive samples represents the first detection of IHNV-RNA in wild brown trout in Switzerland. Compared to SPNT, the RT-PCR method detected, as with virus isolation, a much lower number of positive cases; reasons for this discrepancy are discussed. Our results indicate that RT-PCR can not only be successfully applied in field surveys, but may also be slightly more sensitive than virus isolation. However, in a titration experiment under laboratory conditions, the sensitivity of RT-PCR was not significantly higher when compared with virus isolation.
Resumo:
A new technique to porewater extraction from claystone employs advective displacement of the in situ porewater by traced artificial porewater. Monitoring of tracer breakthrough yields species-specific transport properties. Results for Opalinus Clay from the Mont Terri Research Laboratory indicate that the chemical disturbances due to the method are minimal, and the observed significant differences in transport properties for Br– and 2H are in agreement with existing data. Sampling times are 2–4 months, and observation of tracer breakthrough takes 12–24 months at hydraulic conductivity of ∼10-13 m/s.
Resumo:
OBJECTIVE To analytically validate a gas concentration of chromatography-mass spectrometry (GC-MS) method for measurement of 6 amino acids in canine serum samples and to assess the stability of each amino acid after sample storage. SAMPLES Surplus serum from 80 canine samples submitted to the Gastrointestinal Laboratory at Texas A&M University and serum samples from 12 healthy dogs. PROCEDURES GC-MS was validated to determine precision, reproducibility, limit of detection, and percentage recovery of known added concentrations of 6 amino acids in surplus serum samples. Amino acid concentrations in serum samples from healthy dogs were measured before (baseline) and after storage in various conditions. RESULTS Intra- and interassay coefficients of variation (10 replicates involving 12 pooled serum samples) were 13.4% and 16.6% for glycine, 9.3% and 12.4% for glutamic acid, 5.1% and 6.3% for methionine, 14.0% and 15.1% for tryptophan, 6.2% and 11.0% for tyrosine, and 7.4% and 12.4% for lysine, respectively. Observed-to-expected concentration ratios in dilutional parallelism tests (6 replicates involving 6 pooled serum samples) were 79.5% to 111.5% for glycine, 80.9% to 123.0% for glutamic acid, 77.8% to 111.0% for methionine, 85.2% to 98.0% for tryptophan, 79.4% to 115.0% for tyrosine, and 79.4% to 110.0% for lysine. No amino acid concentration changed significantly from baseline after serum sample storage at -80°C for ≤ 7 days. CONCLUSIONS AND CLINICAL RELEVANCE GC-MS measurement of concentration of 6 amino acids in canine serum samples yielded precise, accurate, and reproducible results. Sample storage at -80°C for 1 week had no effect on GC-MS results.
Resumo:
Five test runs were performed to assess possible bias when performing the loss on ignition (LOI) method to estimate organic matter and carbonate content of lake sediments. An accurate and stable weight loss was achieved after 2 h of burning pure CaCO3 at 950 °C, whereas LOI of pure graphite at 530 °C showed a direct relation to sample size and exposure time, with only 40-70% of the possible weight loss reached after 2 h of exposure and smaller samples losing weight faster than larger ones. Experiments with a standardised lake sediment revealed a strong initial weight loss at 550 °C, but samples continued to lose weight at a slow rate at exposure of up to 64 h, which was likely the effect of loss of volatile salts, structural water of clay minerals or metal oxides, or of inorganic carbon after the initial burning of organic matter. A further test-run revealed that at 550 °C samples in the centre of the furnace lost more weight than marginal samples. At 950 °C this pattern was still apparent but the differences became negligible. Again, LOI was dependent on sample size. An analytical LOI quality control experiment including ten different laboratories was carried out using each laboratory's own LOI procedure as well as a standardised LOI procedure to analyse three different sediments. The range of LOI values between laboratories measured at 550 °C was generally larger when each laboratory used its own method than when using the standard method. This was similar for 950 °C, although the range of values tended to be smaller. The within-laboratory range of LOI measurements for a given sediment was generally small. Comparisons of the results of the individual and the standardised method suggest that there is a laboratory-specific pattern in the results, probably due to differences in laboratory equipment and/or handling that could not be eliminated by standardising the LOI procedure. Factors such as sample size, exposure time, position of samples in the furnace and the laboratory measuring affected LOI results, with LOI at 550 °C being more susceptible to these factors than LOI at 950 °C. We, therefore, recommend analysts to be consistent in the LOI method used in relation to the ignition temperatures, exposure times, and the sample size and to include information on these three parameters when referring to the method.