3 resultados para laboratory experiences

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neospora caninum represents one of the most frequent abortifaciant organisms worldwide. The parasite is diaplacentally transmitted from the pregnant cow to the fetus, where it normally leads to the delivery of a healthy, however persistently infected calf. Abortion thus is a relative rare event. The transmission of bovine neosporosis occurs in more than 90% of the cases vertically due to the endogenous reactivation of a persistently infected mother. Exogenous infections are therefore responsible for less than 10% of the cases.The question arises about which infection sources may be relevant in this context. In Switzerland, the role of dogs as definitive hosts has been shown to be of low significance in that respect. Recently, discussion focused on the potential of infectious bull semen following natural or artificial insemination. Thus, a few years ago a report documented the detectability of N. caninum-DNA in the semen of naturally infected bulls by nested-PCR. As a consequence, we decided to gain own experience by investigating 5 separate semen specimens per animal, originating from 20 N. caninum-seropositive bulls used for artificial insemination in Switzerland. All probes turned out to be negative by nested PCR. Based upon our laboratory experiences, the potential bull semen-associated Neospora-problem seems not to affect the Swiss bull population, thus there is no evidence to include further respective means of control.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The exponential increase in cardioverter-defibrillator implantations has resulted in a need for safe implantations that do not require long waiting periods. We report intraoperative and follow-up results in 48 patients with ventricular tachyarrhythmias who underwent cardioverter-defibrillator implantation in the catheterization laboratory. Twenty-six (54%) patients had their first cardioverter-defibrillator implant (group 1), and 22 (46%) patients underwent pulse-generator replacement (group 2). In all patients, cardioverter-defibrillator implant or pulse-generator replacement was performed with the patient under general anesthesia. In 25 (96%) of 26 patients in group 1, cardioverter-defibrillator implantation was possible with a mean defibrillation threshold of 13 +/- 8 J. One patient had a defibrillation threshold of > 25 J, and therefore cardioverter-defibrillator implant was not achieved. This patient underwent epicardial device implantation 1 day later. Another patient in group 1 had vessel rupture (vena subclavia) intraoperatively. During a mean follow-up of 2 +/- 1 months, two patients died from congestive heart failure 2 and 4 months after device implantation. An infection occurred in one patient in group 2, 3 months after generator replacement. In conclusion, these data show that in the majority of patients cardioverter-defibrillator implantation in the catheterization laboratory is safe and has a low complication rate and therefore can generally be recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Implementation of user-friendly, real-time, electronic medical records for patient management may lead to improved adherence to clinical guidelines and improved quality of patient care. We detail the systematic, iterative process that implementation partners, Lighthouse clinic and Baobab Health Trust, employed to develop and implement a point-of-care electronic medical records system in an integrated, public clinic in Malawi that serves HIV-infected and tuberculosis (TB) patients. METHODS Baobab Health Trust, the system developers, conducted a series of technical and clinical meetings with Lighthouse and Ministry of Health to determine specifications. Multiple pre-testing sessions assessed patient flow, question clarity, information sequencing, and verified compliance to national guidelines. Final components of the TB/HIV electronic medical records system include: patient demographics; anthropometric measurements; laboratory samples and results; HIV testing; WHO clinical staging; TB diagnosis; family planning; clinical review; and drug dispensing. RESULTS Our experience suggests that an electronic medical records system can improve patient management, enhance integration of TB/HIV services, and improve provider decision-making. However, despite sufficient funding and motivation, several challenges delayed system launch including: expansion of system components to include of HIV testing and counseling services; changes in the national antiretroviral treatment guidelines that required system revision; and low confidence to use the system among new healthcare workers. To ensure a more robust and agile system that met all stakeholder and user needs, our electronic medical records launch was delayed more than a year. Open communication with stakeholders, careful consideration of ongoing provider input, and a well-functioning, backup, paper-based TB registry helped ensure successful implementation and sustainability of the system. Additional, on-site, technical support provided reassurance and swift problem-solving during the extended launch period. CONCLUSION Even when system users are closely involved in the design and development of an electronic medical record system, it is critical to allow sufficient time for software development, solicitation of detailed feedback from both users and stakeholders, and iterative system revisions to successfully transition from paper to point-of-care electronic medical records. For those in low-resource settings, electronic medical records for integrated care is a possible and positive innovation.