52 resultados para intuitive robot programming
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We have developed a haptic-based approach for retraining of interjoint coordination following stroke called time-independent functional training (TIFT) and implemented this mode in the ARMin III robotic exoskeleton. The ARMin III robot was developed by Drs. Robert Riener and Tobias Nef at the Swiss Federal Institute of Technology Zurich (Eidgenossische Technische Hochschule Zurich, or ETH Zurich), in Zurich, Switzerland. In the TIFT mode, the robot maintains arm movements within the proper kinematic trajectory via haptic walls at each joint. These arm movements focus training of interjoint coordination with highly intuitive real-time feedback of performance; arm movements advance within the trajectory only if their movement coordination is correct. In initial testing, 37 nondisabled subjects received a single session of learning of a complex pattern. Subjects were randomized to TIFT or visual demonstration or moved along with the robot as it moved though the pattern (time-dependent [TD] training). We examined visual demonstration to separate the effects of action observation on motor learning from the effects of the two haptic guidance methods. During these training trials, TIFT subjects reduced error and interaction forces between the robot and arm, while TD subject performance did not change. All groups showed significant learning of the trajectory during unassisted recall trials, but we observed no difference in learning between groups, possibly because this learning task is dominated by vision. Further testing in stroke populations is warranted.
Resumo:
When healthy observers make a saccade that is erroneously directed toward a distracter stimulus, they often produce a corrective saccade within 100ms after the end of the primary saccade. Such short inter-saccadic intervals indicate that programming of the secondary saccade has been initiated prior to the execution of the primary saccade and hence that the two saccades have been programmed concurrently. Here we show that concurrent saccade programming is bilaterally impaired in left spatial neglect, a strongly lateralized disorder of visual attention resulting from extensive right cerebral damage. Neglect patients were asked to make saccades to targets presented left or right of fixation while disregarding a distracter presented in the opposite hemifield. We examined those experimental trials on which participants first made a saccade to the distracter, followed by a secondary (corrective) saccade to the target. Compared to healthy and right-hemisphere damaged control participants the proportion of secondary saccades directing gaze to the target instead of bringing it even closer to the distracter was bilaterally reduced in neglect patients. In addition, the characteristic reduction of secondary saccade latency observed in both control groups was absent in neglect patients, whether the secondary saccade was directed to the left or right hemifield. This pattern is consistent with a severe, bilateral impairment of concurrent saccade programming in left spatial neglect.
Knowing the future: partial foreknowledge effects on the programming of prosaccades and antisaccades
Resumo:
Foreknowledge about the demands of an upcoming trial may be exploited to optimize behavioural responses. In the current study we systematically investigated the benefits of partial foreknowledge--that is, when some but not all aspects of a future trial are known in advance. For this we used an ocular motor paradigm with horizontal prosaccades and antisaccades. Predictable sequences were used to create three partial foreknowledge conditions: one with foreknowledge about the stimulus location only, one with foreknowledge about the task set only, and one with foreknowledge about the direction of the required response only. These were contrasted with a condition of no-foreknowledge and a condition of complete foreknowledge about all three parameters. The results showed that the three types of foreknowledge affected saccadic efficiency differently. While foreknowledge about stimulus-location had no effect on efficiency, task foreknowledge had some effect and response-foreknowledge was as effective as complete foreknowledge. Foreknowledge effects on switch costs followed a similar pattern in general, but were not specific for switching of the trial attribute for which foreknowledge was available. We conclude that partial foreknowledge has a differential effect on efficiency, most consistent with preparatory activation of a motor schema in advance of the stimulus, with consequent benefits for both switched and repeated trials.
Resumo:
Conclusion: A robot built specifically for stereotactic cochlear implantation provides equal or better accuracy levels together with a better integration into a clinical environment, when compared to existing approaches based on industrial robots. Objectives: To evaluate the technical accuracy of a robotic system developed specifically for lateral skull base surgery in an experimental setup reflecting the intended clinical application. The invasiveness of cochlear electrode implantation procedures may be reduced by replacing the traditional mastoidectomy with a small tunnel slightly larger in diameter than the electrode itself. Methods: The end-to-end accuracy of the robot system and associated image-guided procedure was evaluated on 15 temporal bones of whole head cadaver specimens. The main components of the procedure were as follows: reference screw placement, cone beam CT scan, computer-aided planning, pair-point matching of the surgical plan, robotic drilling of the direct access tunnel, and post-operative cone beam CT scan and accuracy assessment. Results: The mean accuracy at the target point (round window) was 0.56 ± 41 mm with an angular misalignment of 0.88 ± 0.41°. The procedural time of the registration process through the completion of the drilling procedure was 25 ± 11 min. The robot was fully operational in a clinical environment.
Resumo:
The historical context in which saccades are made influences their latency and error rates, but less is known about how context influences their spatial parameters. We recently described a novel spatial bias for antisaccades, in which the endpoints of these responses deviate towards alternative goal locations used in the same experimental block, and showed that expectancy (prior probability) is at least partly responsible for this 'alternate-goal bias'. In this report we asked whether trial history also plays a role. Subjects performed antisaccades to a stimulus randomly located on the horizontal meridian, on a 40° angle downwards from the horizontal meridian, or on a 40° upward angle, with all three locations equally probable on any given trial. We found that the endpoints of antisaccades were significantly displaced towards the goal location of not only the immediately preceding trial (n - 1) but also the penultimate (n - 2) trial. Furthermore, this bias was mainly present for antisaccades with a short latency of <250 ms and was rapidly corrected by secondary saccades. We conclude that the location of recent antisaccades biases the spatial programming of upcoming antisaccades, that this historical effect persists over many seconds, and that it influences mainly rapidly generated eye movements. Because corrective saccades eliminate the historical bias, we suggest that the bias arises in processes generating the response vector, rather than processes generating the perceptual estimate of goal location.
Resumo:
There exists an association between pathologic events occurring during early life and the development of cardiovascular disease in adulthood. For example, transient perinatal hypoxemia predisposes to exaggerated hypoxic pulmonary hypertension and preeclampsia predisposes the offspring to pulmonary and systemic endothelial dysfunction later in life. The latter finding offers a scientific basis for observations demonstrating an increased risk for premature cardiovascular morbidity in this population. Very recently, we showed that offspring of assisted reproductive technologies also display generalized vascular dysfunction and early arteriosclerosis. Studies in animal models have provided evidence that oxidative stress and/or epigenetic alterations play an important pathophysiological role in the fetal programming of cardiovascular disease.
Resumo:
High altitude constitutes an exciting natural laboratory for medical research. While initially, the aim of high-altitude research was to understand the adaptation of the organism to hypoxia and find treatments for altitude-related diseases, over the past decade or so, the scope of this research has broadened considerably. Two important observations led to the foundation for the broadening of the scientific scope of high-altitude research. First, high-altitude pulmonary edema (HAPE) represents a unique model which allows studying fundamental mechanisms of pulmonary hypertension and lung edema in humans. Secondly, the ambient hypoxia associated with high-altitude exposure facilitates the detection of pulmonary and systemic vascular dysfunction at an early stage. Here, we review studies that, by capitalizing on these observations, have led to the description of novel mechanisms underpinning lung edema and pulmonary hypertension and to the first direct demonstration of fetal programming of vascular dysfunction in humans.
Resumo:
PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.