15 resultados para interferences

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary zone electrophoresis (CZE) in fused-silica capillaries is an effective analytical approach for the separation and determination of the transferrin (Tf) isoforms and thus carbohydrate-deficient transferrin (CDT) in human serum. Sera of patients with progressed liver cirrhosis are prone to interferences in the beta region which prevent the proper determination of CDT by CZE without additional sample preparation. Efforts to identify, reduce or even eliminate these interferences have been undertaken. Data obtained by ultrafiltration, affinity subtraction procedures using protein A, protein L and antibodies against immunoglobulins or Tf, and immunopurification of Tf suggest that the interferences in the patient sera are caused by increased levels of IgA and IgM and are best eliminated by immunopurification. Avian IgY antibody spin column immunocapture of serum Tf followed by CZE analysis of the stripped and concentrated fraction is shown to provide an attractive approach for CDT monitoring in sera with beta region interferences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Recent anatomical-functional studies have transformed our understanding of cerebral motor control away from a hierarchical structure and toward parallel and interconnected specialized circuits. Subcortical electrical stimulation during awake surgery provides a unique opportunity to identify white matter tracts involved in motor control. For the first time, this study reports the findings on motor modulatory responses evoked by subcortical stimulation and investigates the cortico-subcortical connectivity of cerebral motor control. Experimental design: Twenty-one selected patients were operated while awake for frontal, insular, and parietal diffuse low-grade gliomas. Subcortical electrostimulation mapping was used to search for interference with voluntary movements. The corresponding stimulation sites were localized on brain schemas using the anterior and posterior commissures method. Principal observations: Subcortical negative motor responses were evoked in 20/21 patients, whereas acceleration of voluntary movements and positive motor responses were observed in three and five patients, respectively. The majority of the stimulation sites were detected rostral of the corticospinal tract near the vertical anterior-commissural line, and additional sites were seen in the frontal and parietal white matter. Conclusions: The diverse interferences with motor function resulting in inhibition and acceleration imply a modulatory influence of the detected fiber network. The subcortical stimulation sites were distributed veil-like, anterior to the primary motor fibers, suggesting descending pathways originating from premotor areas known for negative motor response characteristics. Further stimulation sites in the parietal white matter as well as in the anterior arm of the internal capsule indicate a large-scale fronto-parietal motor control network. Hum Brain Mapp, 2012. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Irreversible, nonenzymatic glycation of the haemoglobin A beta chain leads to the formation of haemoglobin A1c (HbA1c), a stable minor haemoglobin component with enhanced electrophoretic mobility. The rate of formation of HbA1c is directly proportional to the ambient glucose concentration. HbA1c is commonly used to assess long-term blood glucose control in patients with diabetes mellitus, because the HbA1c value has been shown to predict the risk for the development of many of the chronic complications in diabetes. There are currently four principal glycohaemoglobin assay techniques (ion-exchange chromatography, electrophoresis, affinity chromatography and immunoassays) and over 20 methods that measure different glycated products. The ranges indicating good and poor glycaemic control can vary markedly between different assays. At the moment values differ between methodologies and even between different laboratories using the same methodology. Optimal use of HbA1c testing requires standardisation. There is progress towards international standardisation and improved precision of HbA1c which will lead to all assays reporting results in a standardised way. Clinicians ordering HbA1c testing for their patients should be aware of the type of assay method used, the reference interval, potential assay interferences (e.g. haemoglobinopathies, chronic alcohol ingestion, carbamylation products in uraemia) and assay performance. And they should know that a variety of factors have been shown to directly influence HbA1c values, e.g. iron deficiency anaemia, chronic renal failure and shortened red blood cell life span.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data obtained with two CZE assays for determining carbohydrate-deficient transferrin (CDT) in human serum under routine conditions, the CAPILLARYS CDT and the high-resolution CEofix (HR-CEofix) CDT methods, are in agreement with patient sera that do not exhibit interferences, high trisialo-transferrin (Tf) levels or genetic variants. HR-CEofix CDT levels are somewhat higher compared to those obtained with the CAPILLARYS method and this bias corresponds to the difference of the upper reference values of the two assays. The lower resolution between disialo-Tf and trisialo-Tf observed in the CAPILLARYS system (mean: 1.24) compared to HR-CEofix (mean: 1.74) is believed to be the key for this difference. For critical sera with high trisialo-Tf levels, genetic variants, or certain interferences in the beta-region, the HR-CEofix approach is demonstrated to perform better than CAPILLARYS. However, the determination of CDT with the HR-CEofix method can also be hampered with interferences. Results with disialo-Tf values larger than 3% in the absence of asialo-Tf should be evaluated with immunosubtraction of Tf and possibly also confirmed with another CZE method or by HPLC. Furthermore, data gathered with the N Latex CDT direct immunonephelometric assay suggest that this assay can be used for screening purposes. To reduce the number of false negative results, CDT data above 2.0% should be confirmed using a separation method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wireless Mesh Networks (WMN) have proven to be a key technology for increased network coverage of Internet infrastructures. The development process for new protocols and architectures in the area of WMN is typically split into evaluation by network simulation and testing of a prototype in a test-bed. Testing a prototype in a real test-bed is time-consuming and expensive. Irrepressible external interferences can occur which makes debugging difficult. Moreover, the test-bed usually supports only a limited number of test topologies. Finally, mobility tests are impractical. Therefore, we propose VirtualMesh as a new testing architecture which can be used before going to a real test-bed. It provides instruments to test the real communication software including the network stack inside a controlled environment. VirtualMesh is implemented by capturing real traffic through a virtual interface at the mesh nodes. The traffic is then redirected to the network simulator OMNeT++. In our experiments, VirtualMesh has proven to be scalable and introduces moderate delays. Therefore, it is suitable for predeployment testing of communication software for WMNs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vielfach konnte in den letzten Jahren die Bedeutung einer langen letzten Fixation vor Bewegungsbeginn – des sogenannten "Quiet Eye" – für die sportmotorische Leistung aufgezeigt werden. Obgleich dieses Phänomens breit untersucht wurde, mangelt es bislang an einer zufriedenstellenden Erklärung. In diesem Beitrag werden daher aktuelle Erklärungsversuche diskutiert. Es zeigt sich, dass vorliegende Beiträge aus der Kognitions- und der ökologischen Psychologie konzeptuelle oder methodische Mängel aufweisen. Aus diesen Gründen wird – zunächst für Aufgaben mit hohen Präzisionsanforderungen – ein Inhibitionsmechanismus zur Erklärung des Quiet-Eye-Phänomens vorgeschlagen mit der zentralen Aussage, dass die Verarbeitung leistungsrelevanter Hinweisreize durch ein "ruhiges Auge" von Störungen abgeschirmt wird. Abschließend kann gezeigt werden, dass sich der vorgeschlagene Mechanismus mit der bestehenden Befundlage als kompatibel erweist und er die Ableitung weitergehender Vorhersagen erlaubt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of the large variability in the pharmacokinetics of anti-HIV drugs, therapeutic drug monitoring in patients may contribute to optimize the overall efficacy and safety of antiretroviral therapy. An LC–MS/MS method for the simultaneous assay in plasma of the novel antiretroviral agents rilpivirine (RPV) and elvitegravir (EVG) has been developed to that endeavor. Plasma samples (100 μL) extraction is performed by protein precipitation with acetonitrile, and the supernatant is subsequently diluted 1:1 with 20-mM ammonium acetate/MeOH 50:50. After reverse-phase chromatography, quantification of RPV and EVG, using matrix-matched calibration samples, is performed by electrospray ionization–triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The stable isotopic-labeled compounds RPV-13C6 and EVG-D6 were used as internal standards. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<6.4%), as well as EVG and RPV short and long-term stability in plasma. Calibration curves were validated over the clinically relevant concentrations ranging from 5 to 2500 ng/ml for RPV and from 50 to 5000 ng/ml for EVG. The method is precise (inter-day CV%: 3–6.3%) and accurate (3.8–7.2%). Plasma samples were found to be stable (<15%) in all considered conditions (RT/48 h, +4°C/48 h, −20°C/3 months and 60°C/1 h). Selected metabolite profiles analysis in patients' samples revealed the presence of EVG glucuronide, that was well separated from parent EVG, allowing to exclude potential interferences through the in-source dissociation of glucuronide to parent drug. This new, rapid and robust LCMS/MS assay for the simultaneous quantification of plasma concentrations of these two major new anti-HIV drugs EVG and RPV offers an efficient analytical tool for clinical pharmacokinetics studies and routine therapeutic drug monitoring service.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CZE-based assays for carbohydrate-deficient transferrin (CDT) in which serum is mixed with an Fe(III) ion-containing solution prior to analysis are effective approaches for the determination of CDT in patient samples. Sera of patients with progressed diseases, however, are prone to interferences comigrating with transferrin (Tf) that prevent the proper determination of CDT by CZE in these samples. The need of a simple and economic approach to immunoextract Tf from human serum prompted us to investigate the use of a laboratory-made anti-Tf spin column containing polyclonal rabbit anti-human Tf antibodies linked to Sepharose 4 Fast Flow beads. This article reports extraction column manufacturing and column characterization with sera having normal and elevated CDT levels. The developed procedure was applied to a number of relevant hepatology and dialysis patient samples and could thereby be shown to represent an effective method for extraction and concentration of all Tf isoforms. Furthermore, lipemic sera were delipidated using a mixture of diisopropyl ether and butanol prior to immunoextraction. CDT could unambiguously be determined in all pretreated samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mobile ad-hoc networks (MANETs) and wireless sensor networks (WSNs) have been attracting increasing attention for decades due to their broad civilian and military applications. Basically, a MANET or WSN is a network of nodes connected by wireless communication links. Due to the limited transmission range of the radio, many pairs of nodes in MANETs or WSNs may not be able to communicate directly, hence they need other intermediate nodes to forward packets for them. Routing in such types of networks is an important issue and it poses great challenges due to the dynamic nature of MANETs or WSNs. On the one hand, the open-air nature of wireless environments brings many difficulties when an efficient routing solution is required. The wireless channel is unreliable due to fading and interferences, which makes it impossible to maintain a quality path from a source node to a destination node. Additionally, node mobility aggravates network dynamics, which causes frequent topology changes and brings significant overheads for maintaining and recalculating paths. Furthermore, mobile devices and sensors are usually constrained by battery capacity, computing and communication resources, which impose limitations on the functionalities of routing protocols. On the other hand, the wireless medium possesses inherent unique characteristics, which can be exploited to enhance transmission reliability and routing performance. Opportunistic routing (OR) is one promising technique that takes advantage of the spatial diversity and broadcast nature of the wireless medium to improve packet forwarding reliability in multihop wireless communication. OR combats the unreliable wireless links by involving multiple neighboring nodes (forwarding candidates) to choose packet forwarders. In opportunistic routing, a source node does not require an end-to-end path to transmit packets. The packet forwarding decision is made hop-by-hop in a fully distributed fashion. Motivated by the deficiencies of existing opportunistic routing protocols in dynamic environments such as mobile ad-hoc networks or wireless sensor networks, this thesis proposes a novel context-aware adaptive opportunistic routing scheme. Our proposal selects packet forwarders by simultaneously exploiting multiple types of cross-layer context information of nodes and environments. Our approach significantly outperforms other routing protocols that rely solely on a single metric. The adaptivity feature of our proposal enables network nodes to adjust their behaviors at run-time according to network conditions. To accommodate the strict energy constraints in WSNs, this thesis integrates adaptive duty-cycling mechanism to opportunistic routing for wireless sensor nodes. Our approach dynamically adjusts the sleeping intervals of sensor nodes according to the monitored traffic load and the estimated energy consumption rate. Through the integration of duty cycling of sensor nodes and opportunistic routing, our protocol is able to provide a satisfactory balance between good routing performance and energy efficiency for WSNs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The recently described complex nature of some dehydrin-coding sequences in Trifolium repens could explain the considerable variability among transcripts originating from a single gene.1 For some of the sequences the existence of natural antisense transcripts (NAT s), which could form sense-antisense (SAS) pairs, was predicted. The present study demonstrates that cis-natural antisense transcripts of 2 dehydrin types (YnKn and YnSKn) accumulate in white clover plants subjected to treatments with polyethylene glycol (PEG), abscisic acid (ABA), and high salt concentration. The isolated YnKn cis-NAT s mapped to sequence site enriched in alternative start codons. Some of the sense-antisense pairs exhibited inverse expression with differing profiles which depended on the applied stress. A natural antisense transcript coding for an ABC F family protein (a trans-NAT) which shares short sequence homology with YnSKn dehydrin was identified in plants subjected to salt stress. Forthcoming experiments will evaluate the impact of NAT s on transcript abundances, elucidating the role of transcriptional and post-transcriptional interferences in the regulation of dehydrin levels under various abiotic stresses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ketamine and norketamine are being transported across the blood brain barrier and are also entering from blood into cerebrospinal fluid (CSF). Enantioselective distributions of these compounds in brain and CSF have never been determined. The enantioselective CE based assay previously developed for equine plasma was adapted to the analysis of these compounds in equine brain via use of an acidic pre-extraction of interferences prior to liquid/liquid extraction at alkaline pH. CSF can be treated as plasma. With 100 mg of brain tissue and 0.5 mL of CSF or plasma, assay conditions for up to 30 nmol/g and 6 μM, respectively, of each enantiomer with LOQs of 0.5 nmol/g and 0.1 μM, respectively, were established and the assays were applied to equine samples. CSF and plasma samples analyzed stemmed from anesthetized patient horses and brain, CSF and plasma were obtained from anesthetized horses that were euthanized with an overdose of pentobarbital. Data obtained indicate that ketamine and norketamine enantiomers are penetrating into brain and CSF with those of ketamine being more favorably transported than norketamine, whereas metabolites of norketamine are hindered. More work is required to properly investigate possible stereoselectivities of the ketamine metabolism and transport of metabolites from blood into brain tissue and CSF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND A large cohort study recently reported high pain scores after caesarean section (CS). The aim of this study was to analyse how pain after CS interferes with patients' activities and to identify possible causes of insufficient pain treatment. METHODS We analysed pain scores, pain-related interferences (with movement, deep breathing, mood and sleep), analgesic techniques, analgesic consumption, adverse effects and the wish to have received more analgesics during the first 24 h after surgery. To better evaluate the severity of impairment by pain, the results of CS patients were compared with those of patients undergoing hysterectomy. RESULTS CS patients (n = 811) were compared with patients undergoing abdominal, laparoscopic-assisted vaginal or vaginal hysterectomy (n = 2406, from 54 hospitals). Pain intensity, wish for more analgesics and most interference outcomes were significantly worse after CS compared with hysterectomies. CS patients with spinal or general anaesthesia and without patient-controlled analgesia (PCA) received significantly less opioids on the ward (62% without any opioid) compared with patients with PCA (p < 0.001). Patients with PCA reported pain-related interference with movement and deep breathing between 49% and 52% compared with patients without PCA (between 68% and 73%; p-values between 0.004 and 0.013; not statistically significant after correction for multiple testing). CONCLUSION In daily clinical practice, pain after CS is much higher than previously thought. Pain management was insufficient compared with patients undergoing hysterectomy. Unfavourable outcome was mainly associated with low opioid administration after CS. Contradictory pain treatment guidelines for patients undergoing CS and for breastfeeding mothers might contribute to reluctance of opioid administration in CS patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present precise iron stable isotope ratios measured by multicollector-ICP mass spectrometry (MC-ICP-MS) of human red blood cells (erythrocytes) and blood plasma from 12 healthy male adults taken during a clinical study. The accurate determination of stable isotope ratios in plasma first required substantial method development work, as minor iron amounts in plasma had to be separated from a large organic matrix prior to mass-spectrometric analysis to avoid spectroscopic interferences and shifts in the mass spectrometer's mass-bias. The 56Fe/54Fe ratio in erythrocytes, expressed as permil difference from the “IRMM-014” iron reference standard (δ56/54Fe), ranges from −3.1‰ to −2.2‰, a range typical for male Caucasian adults. The individual subject erythrocyte iron isotope composition can be regarded as uniform over the 21 days investigated, as variations (±0.059 to ±0.15‰) are mostly within the analytical precision of reference materials. In plasma, δ56/54Fe values measured in two different laboratories range from −3.0‰ to −2.0‰, and are on average 0.24‰ higher than those in erythrocytes. However, this difference is barely resolvable within one standard deviation of the differences (0.22‰). Taking into account the possible contamination due to hemolysis (iron concentrations are only 0.4 to 2 ppm in plasma compared to approx. 480 ppm in erythrocytes), we model the pure plasma δ56/54Fe to be on average 0.4‰ higher than that in erythrocytes. Hence, the plasma iron isotope signature lies between that of the liver and that of erythrocytes. This difference can be explained by redox processes involved during cycling of iron between transferrin and ferritin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The isotope composition of selenium (Se) can provide important constraints on biological, geochemical, and cosmochemical processes taking place in different reservoirs on Earth and during planet formation. To provide precise qualitative and quantitative information on these processes, accurate and highly precise isotope data need to be obtained. The currently applied ICP-MS methods for Se isotope measurements are compromised by the necessity to perform a large number of interference corrections. Differences in these correction methods can lead to discrepancies in published Se isotope values of rock standards which are significantly higher than the acclaimed precision. An independent analytical approach applying a double spike (DS) and state-of-the-art TIMS may yield better precision due to its smaller number of interferences and could test the accuracy of data obtained by ICP-MS approaches. This study shows that the precision of Se isotope measurements performed with two different Thermo Scientific™ Triton™ Plus TIMS is distinctly deteriorated by about ±1‰ (2 s.d.) due to δ80/78Se by a memory Se signal of up to several millivolts and additional minor residual mass bias which could not be corrected for with the common isotope fractionation laws. This memory Se has a variable isotope composition with a DS fraction of up to 20% and accumulates with increasing number of measurements. Thus it represents an accumulation of Se from previous Se measurements with a potential addition from a sample or machine blank. Several cleaning techniques of the MS parts were tried to decrease the memory signal, but were not sufficient to perform precise Se isotope analysis. If these serious memory problems can be overcome in the future, the precision and accuracy of Se isotope analysis with TIMS should be significantly better than those of the current ICP-MS approaches.