21 resultados para instrumentation: miscellaneous

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Root canal treatment is a frequently performed dental procedure and is carried out on teeth in which irreversible pulpitis has led to necrosis of the dental pulp. Removal of the necrotic tissue remnants and cleaning and shaping of the root canal are important phases of root canal treatment. Treatment options include the use of hand and rotary instruments and methods using ultrasonic or sonic equipment. OBJECTIVES: The objectives of this systematic review of randomized controlled trials were to determine the relative clinical effectiveness of hand instrumentation versus ultrasonic instrumentation alone or in conjunction with hand instrumentation for orthograde root canal treatment of permanent teeth. MATERIAL AND METHODS: The search strategy retrieved 226 references from the Cochrane Oral Health Group Trials Register (7), the Cochrane Central Register of Controlled Trials (CENTRAL) (12), MEDLINE (192), EMBASE (8) and LILACS (7). No language restriction was applied. The last electronic search was conducted on December 13th, 2007. Screening of eligible studies was conducted in duplicate and independently. RESULTS: Results were to be expressed as fixed-effect or random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. No eligible randomized controlled trials were identified. CONCLUSIONS: This review illustrates the current lack of published or ongoing randomized controlled trials and the unavailability of high-level evidence based on clinically relevant outcomes referring to the effectiveness of ultrasonic instrumentation used alone or as an adjunct to hand instrumentation for orthograde root canal treatment. In the absence of reliable research-based evidence, clinicians should base their decisions on clinical experience, individual circumstances and in conjunction with patients' preferences where appropriate. Future randomized controlled trials might focus more closely on evaluating the effectiveness of combinations of these interventions with an emphasis on not only clinically relevant, but also patient-centered outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors conducted a retrospective study on 24 consecutive adolescent scoliosis patients, 11 of whom were instrumented with hooks and 13 with hooks and screws (hybrid technique). The mean preoperative Cobb angle was 62.2 degrees (range: 48 degrees-96 degrees). The mean correction of the primary curve was 56.6% at followup after +/- 1.18 years ; there was no statistically significant difference between groups. Special attention was given to the postoperative quality of life (QOL) by means of the following scores: COMI patient self-assessment, SF-36, ODI, and VAS. Again, there was no statistical difference between groups but, interestingly, there was no correlation between QOL and degree of correction, after a follow-up period of +/- 2.1 years. Nevertheless, on the COMI patient self-assessment, there was a high level of satisfaction with treatment. Further studies should concentrate on how to achieve a high QOL, and abandon the best possible correction as a primary endpoint of success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positron emission tomography (PET) has proven to be a clinically valuable imaging modality, particularly for oncology staging and therapy follow-up. The introduction of combined PET/CT imaging has helped address challenging imaging situations when anatomical information on PET-only was inadequate for accurate lesion localization. After a decade of PET/CT these combined systems have matured technically. Today, whole-body oncology staging is available with PET/CT in 15 min, or less. This review details recent developments in combined PET/CT instrumentation and points to implications for major applications in clinical oncology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment, is predominantly a domain of in vitro experiments on spinal loading simulators. Most existing approaches to measure spinal stiffness intraoperatively in an in vivo environment use a distractor. However, these concepts usually assume a planar loading and motion. The objective of our study was to develop and validate an apparatus, that allows to perform intraoperative in vivo measurements to determine both the applied force and the resulting motion in three dimensional space. The proposed setup combines force measurement with an instrumented distractor and motion tracking with an optoelectronic system. As the orientation of the applied force and the three dimensional motion is known, not only force-displacement, but also moment-angle relations could be determined. The validation was performed using three cadaveric lumbar ovine spines. The lateral bending stiffness of two motion segments per specimen was determined with the proposed concept and compared with the stiffness acquired on a spinal loading simulator which was considered to be gold standard. The mean values of the stiffness computed with the proposed concept were within a range of ±15% compared to data obtained with the spinal loading simulator under applied loads of less than 5 Nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract. This article provides the reader with practical information to be applied to the various remaining causes of macular edema. Some macular edemas linked to ocular diseases like radiotherapy after ocular melanomas remained of poor functional prognosis due to the primary disease. On the contrary, macular edemas occurring after retinal detachment or after some systemic or local treatment use are often temporary. Macular edema associated with epiretinal membranes or vitreomacular traction is the main cause of poor functional recovery. However, the delay to observe a significant improvement of vision after surgery should be long, as usually observed in tractional myopic vitreoschisis. Finally, some circumstances of macular edemas such as hemangiomas or macroaneurysms should be treated, if symptomatic, with the treatments currently used in diabetic macular edema or exudative macular degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter provides the reader with practical information to be applied to the various remaining causes of macular edema. Some clinical cases of macular edema linked to ocular diseases like postradiotherapy for ocular melanomas remained of poor functional prognosis due to the primary disease. On the contrary, macular edema occurring after retinal detachment or after diverse systemic or local treatment use is often temporary. Macular edema associated with epiretinal membranes or vitreomacular traction is the main cause of poor functional recovery. In other cases, as in tractional myopic vitreoschisis, the delay to observe a significant improvement of the vision after surgery should be long. Finally, macular edema associated with hemangiomas or macroaneurysms should be treated, if symptomatic, using the same current treatment as in diabetic macular edema or exudative macular degeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The objective of the study was to evaluate the efficacy of an additional usage of a diamond-coated curette on surface roughness, adhesion of periodontal ligament (PDL) fibroblasts, and of Streptococcus gordonii in vitro. MATERIALS AND METHODS: Test specimens were prepared from extracted teeth and exposed to instrumentation with conventional Gracey curettes with or without additional use of diamond-coated curettes. Surface roughness (Ra and Rz) was measured before and following treatment. In addition, the adhesion of PDL fibroblasts for 72 h and adhesion of S. gordonii ATCC 10558 for 2 h have been determined. RESULTS: Instrumentation with conventional Gracey curettes reduced surface roughness (median Ra before: 0.36 μm/after: 0.25 μm; p < 0.001; median Rz before: 2.34 μm/after: 1.61 μm; p < 0.001). The subsequent instrumentation with the diamond-coated curettes resulted in a median Ra of 0.31 μm/Rz of 2.06 μm (no significance in comparison to controls). The number of attached PDL fibroblasts did not change following scaling with Gracey curettes. The additional instrumentation with the diamond-coated curettes resulted in a two-fold increase in the number of attached PDL fibroblasts but not in the numbers of adhered bacteria. CONCLUSIONS: Treatment of root surfaces with conventional Gracey curettes followed by subsequent polishing with diamond-coated curettes may result in a root surface which provides favorable conditions for the attachment of PDL fibroblasts without enhancing microbial adhesion. CLINICAL RELEVANCE: The improved attachment of PDL fibroblasts and the limited microbial adhesion on root surfaces treated with scaling with conventional Gracey curettes followed by subsequent polishing with diamond-coated curettes may favor periodontal wound healing.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spinal instrumentation basically means the implantation of more or less rigid metallic or non-metallic devices which are attached to the spine. These devices function to provide spinal stability and thus facilitate bone healing leading to spinal fusion (spondylodesis). Fundamental biomechanical knowledge and its application serves to improve the performance of the individual spine surgeon with respect to the rate of bony fusion, implant failure or degree of deformity correction. However, biomechanics is inherently linked with (mechano-)biology. And there is still an incomplete understanding of spinal biomechanics and even more so of the underlying biology. Moreover, apparently advantageous biomechanical concepts do not necessarily lead to a better patient outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The definition of spinal instability is still controversial. For this reason, it is essential to better understand the difference in biomechanical behaviour between healthy and degenerated human spinal segments in vivo. A novel computer-assisted instrument was developed with the objective to characterize the biomechanical parameters of the spinal segment. Investigation of the viscoelastic properties as well as the dynamic spinal stiffness was performed during a minimally invasive procedure (microdiscectomy) on five patients. Measurements were performed intraoperatively and the protocol consisted of a dynamic part, where spinal stiffness was computed, and a static part, where force relaxation of the segment under constant elongation was studied. The repeatability of the measurement procedure was demonstrated with five replicated tests. The spinal segment tissues were found to have viscoelastic properties. Preliminary tests confirmed a decrease in stiffness after decompression surgery. Patients with non-relaxed muscles showed higher stiffness and relaxation rate compared to patients with relaxed muscles, which can be explained by the contraction and relaxation reflex of muscles under fast and then static elongation. The results show the usefulness of the biomechanical characterization of the human lumbar spinal segment to improve the understanding of the contribution of individual anatomical structures to spinal stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.