7 resultados para inaccuracy

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

For embolized cerebral aneurysms, the initial occlusion rate is the most powerful parameter to predict aneurysm rerupture and recanalization. However, the occlusion rate is only estimated subjectively in clinical routine. To minimize subjective bias, computer occlusion-rating (COR) was successfully validated for 2D images. To minimize the remaining inaccuracy of 2D-COR, COR was applied to 1.5T 3D MR imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Several conversion tables and formulas have been suggested to correct applanation intraocular pressure (IOP) for central corneal thickness (CCT). CCT is also thought to represent an independent glaucoma risk factor. In an attempt to integrate IOP and CCT into a unified risk factor and avoid uncertain correction for tonometric inaccuracy, a new pressure-to-cornea index (PCI) is proposed. METHODS: PCI (IOP/CCT(3)) was defined as the ratio between untreated IOP and CCT(3) in mm (ultrasound pachymetry). PCI distribution in 220 normal controls, 53 patients with normal-tension glaucoma (NTG), 76 with ocular hypertension (OHT), and 89 with primary open-angle glaucoma (POAG) was investigated. PCI's ability to discriminate between glaucoma (NTG+POAG) and non-glaucoma (controls+OHT) was compared with that of three published formulae for correcting IOP for CCT. Receiver operating characteristic (ROC) curves were built. RESULTS: Mean PCI values were: Controls 92.0 (SD 24.8), NTG 129.1 (SD 25.8), OHT 134.0 (SD 26.5), POAG 173.6 (SD 40.9). To minimise IOP bias, eyes within the same 2 mm Hg range between 16 and 29 mm Hg (16-17, 18-19, etc) were separately compared: control and NTG eyes as well as OHT and POAG eyes differed significantly. PCI demonstrated a larger area under the ROC curve (AUC) and significantly higher sensitivity at fixed 80% and 90% specificities compared with each of the correction formulas; optimum PCI cut-off value 133.8. CONCLUSIONS: A PCI range of 120-140 is proposed as the upper limit of "normality", 120 being the cut-off value for eyes with untreated pressures or=22 mm Hg. PCI may reflect individual susceptibility to a given IOP level, and thus represent a glaucoma risk factor. Longitudinal studies are needed to prove its prognostic value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Few studies have addressed the interaction between instruction content and saccadic eye movement control. To assess the impact of instructions on top-down control, we instructed 20 healthy volunteers to deliberately delay saccade triggering, to make inaccurate saccades or to redirect saccades--i.e. to glimpse towards and then immediately opposite to the target. Regular pro- and antisaccade tasks were used for comparison. Bottom-up visual input remained unchanged and was a gap paradigm for all instructions. In the inaccuracy and delay tasks, both latencies and accuracies were detrimentally impaired by either type of instruction and the variability of latency and accuracy was increased. The intersaccadic interval (ISI) required to correct erroneous antisaccades was shorter than the ISI for instructed direction changes in the redirection task. The word-by-word instruction content interferes with top-down saccade control. Top-down control is a time consuming process, which may override bottom-up processing only during a limited time period. It is questionable whether parallel processing is possible in top-down control, since the long ISI for instructed direction changes suggests sequential planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Time is a basic dimension in psychology, underlying behavior and experience. Timing and time perception constitute implicit processes that are often inaccessible to the individual person. Research in this field has shown that timing is involved in many areas of clinical significance. In the projects presented here, we combine timing with seemingly different fields of research, such as psychopathology, perceptual grouping, and embodied cognition. Focusing on the time scale of the subjective present, we report findings from three different clinical studies: (1) We studied perceived causality in schizophrenia patients, finding that perceptual grouping (‘binding’, ‘Gestalt formation’), which leads to visual causality perceptions, did not distinguish between patients and healthy controls. Patients however did integrate context (provided by the temporal distribution of auditory context stimuli) less into perceptions, in significant contrast to controls. This is consistent with reports of higher inaccuracy in schizophrenia patients’ temporal processing. (2) In a project on auditory Gestalt perception we investigated auditory perceptual grouping in schizophrenia patients. The mean dwell time was positively related to how much patients were prone to auditory hallucinations. Dwell times of auditory Gestalts may be regarded as operationalizations of the subjective present; findings thus suggested that patients with hallucinations had a shorter present. (3) The movement correlations of interacting individuals were used to study the non-verbal synchrony between therapist and patient in psychotherapy sessions. We operationalized the duration of an embodied ‘social present’ by the statistical significance of such associations, finding a window of roughly 5.7 seconds in conversing dyads.We discuss that temporal scales of nowness may be modifiable, e.g., by mindfulness. This yields promising goals for future research on timing in the clinical context: psychotherapeutic techniques may alter binding processes, hence the subjective present of individuals, and may affect the social present in therapeutic interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb−1 of LHC proton–proton collision data taken at centre-of-mass energies of √s = 7 and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the Z resonance is used to set the absolute energy scale. For electrons from Z decays, the achieved calibration is typically accurate to 0.05% in most of the detector acceptance, rising to 0.2% in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2–1% for electrons with a transverse energy of 10 GeV, and is on average 0.3% for photons. The detector resolution is determined with a relative inaccuracy of less than 10% for electrons and photons up to 60 GeV transverse energy, rising to 40% for transverse energies above 500 GeV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background In patients with autoimmune diseases associated with antiphospholipid antibodies, precise management of anticoagulation during extracorporeal circulation (ECC) is complicated. It was the aim of the present study to determine whether antifactor Xa (aXa) activity is useful in guiding heparin therapy during ECC. Methods In 15 patients undergoing cardiac surgery, anticoagulation with unfractionated heparin (UFH) and its reversal with protamine were guided using activated clotting time (ACT) (>400 second during ECC; ≤100 second for UFH reversal). For each ACT, the corresponding aXa activity levels were measured. Results A total of 144 blood samples were obtained. ACT and aXa activity were significantly correlated (r = 0.771, p< 0.0001, Spearman rank-order correlation). Using receiver operating characteristic curve (ROC) analyses, the cutoffvalues for aXa activity were 1.14 IU/mL (area under the ROC curve [AUC]: 0.89; inaccuracy rate: 9.4%) to predict ACT > 400 seconds and 0.55 IU/mL (AUC: 0.85; inaccuracy rate: 13.3%) for ACT ≤ 100 seconds. Conclusion AXa activity is strongly correlated with ACT, and therefore may be feasible for managing anticoagulation with UFH during ECC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyzed observations of interstellar neutral helium (ISN He) obtained from the Interstellar Boundary Explorer (IBEX) satellite during its first six years of operation. We used a refined version of the ISN He simulation model, presented in the companion paper by Sokol et al. (2015b), along with a sophisticated data correlation and uncertainty system and parameter fitting method, described in the companion paper by Swaczyna et al. We analyzed the entire data set together and the yearly subsets, and found the temperature and velocity vector of ISN He in front of the heliosphere. As seen in the previous studies, the allowable parameters are highly correlated and form a four-dimensional tube in the parameter space. The inflow longitudes obtained from the yearly data subsets show a spread of similar to 6 degrees, with the other parameters varying accordingly along the parameter tube, and the minimum chi(2) value is larger than expected. We found, however, that the Mach number of the ISN He flow shows very little scatter and is thus very tightly constrained. It is in excellent agreement with the original analysis of ISN He observations from IBEX and recent reanalyses of observations from Ulysses. We identify a possible inaccuracy in the Warm Breeze parameters as the likely cause of the scatter in the ISN He parameters obtained from the yearly subsets, and we suppose that another component may exist in the signal or a process that is not accounted for in the current physical model of ISN He in front of the heliosphere. From our analysis, the inflow velocity vector, temperature, and Mach number of the flow are equal to lambda(ISNHe) = 255 degrees.8 +/- 0 degrees.5, beta(ISNHe) = 5 degrees.16 +/- 0 degrees.10, T-ISNHe = 7440 +/- 260 K, nu(SNHe) = 25.8 +/- 0.4 km s(-1), and M-ISNHe = 5.079 +/- 0.028, with uncertainties strongly correlated along the parameter tube.