222 resultados para implant esthetics
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Replacement of maxillary front teeth with a fixed, implant supported partial denture with a high laugh line is a demanding procedure. For an optimal esthetic result, no deficiency of bone or soft tissue is acceptable. Submerged implant healing has often been recommended for better predictability in esthetically demanding situations. This case report shows the rehabilitation with a fixed implant supported reconstruction in the upper front and a single implant supported crown in the premolar region. Teeth had to be extracted because of apical lesions, periodontal the gingiva. The technique of delayed, submerged implant placement in the region of 11, 21 and 22 was applied and in the region of 15 a transmucosal implant healing. With a fixed, implant supported partial denture the mucosa in the upper front was conditioned. Ten months after implantation the definitive screwed, fixed partial denture on SPI ELEMENT implants was successfully integrated. In the region 15 a single crown transversally screwed was fixed on a SPI ONE TIME implant. Radiographic data two years after implantation showed a well established periimplant crestal bone level. No prosthetic complications had occurred since the insertion of the reconstruction twelve months ago.
Resumo:
A minimal marginal bone loss around implants during early healing has been considered acceptable. However, the preservation of the marginal bone is related to soft tissue stability and esthetics. Implant designs and surfaces were evaluated to determine their impact on the behavior of the crestal bone. The purpose of this study is to evaluate histologic marginal bone level changes around early loaded, chemically modified, sandblasted acid-etched-surfaced implants with a machined collar (MC) or no MC (NMC).
Resumo:
The new Swiss implant system SPI became available three years ago and is used in combination with fixed and removable prosthetic reconstructions. In a pilot study the clinical procedures were evaluated and data of prosthetic complications of maintenance service were collected. 25 patients participated in the study with a total of 79 SPI implants during the time period from 2003-2004. 37 implants were located in the maxilla and 42 implants in the mandible. Two implants failed during the healing period, but no loaded implant was lost. Thus, the survival rate was 97.5% (77/79). 44 implants supported a fixed prosthesis, including nine single crowns and 33 implants were used in combination with removable partial denture. Four implants were used with ball anchor retention, 29 with bar support. The ELEMENT implant with the low implant shoulder allows very good esthetics. Prosthetic complications and maintenance service during the first year of function was comparable with other implant systems. Since the design of the abutment screws, healing caps and screwdriver was changed, the system has become easier in its application.
Resumo:
OBJECTIVE Recent review articles have shown that open debridement is more effective in the treatment of peri-implantitis than closed therapy. However, surgery may result in marginal recession and compromise esthetics. The purpose of this study was to assess the efficacy of nonsurgical antimicrobial photodynamic therapy (aPDT) in moderate vs severe defects. METHOD AND MATERIALS The study encompassed 16 patients with a total of 18 ailing implants. Ten of these implants showed moderate bone loss (< 5 mm; Group 1) and eight implants severe defects (5 through 8 mm; Group 2). All implants received aPDT without surgical intervention. At baseline and 2 weeks, 3 months, and 6 months after therapy, peri-implant health was assessed including sulcus bleeding index (SBI), probing depth (PD), distance from implant shoulder to marginal mucosa (DIM), and clinical attachment level (CAL). Radiographic evaluation of distance from implant to bone (DIB) allowed comparison of peri-implant hard tissues after 6 months. RESULTS Baseline values for SBI were comparable in both groups. Three months after therapy, in both groups, SBI and CAL decreased significantly. In contrast, after 6 months, CAL and DIB increased significantly in Group 2, not in Group 1. However, DIM-values were not statistically different 6 months after therapy in both groups. CONCLUSION Within the limits of this 6-month study, nonsurgical aPDT could stop bone resorption in moderate peri-implant defects but not in severe defects. However, marginal tissue recession was not significantly different in both groups at the end of the study. Therefore, especially in esthetically important sites, surgical treatment of severe peri-implantitis defects seems to remain mandatory.
Resumo:
OBJECTIVE The aim of the present prospective clinical study was to compare patient-reported outcomes for maxillary conventional dentures and maxillary implant-supported dentures. MATERIAL AND METHODS Twenty-one patients (6 women and 15 men) being edentulous in the maxilla and encountering problems with their existing dentures were included. Twelve patients (4 women and 8 men) received a new set of conventional dentures, due to insufficient dentures. In nine patients (2 women and 7 men), the existing dentures were adjusted by means of relining or rebasing. All patients received implant-supported dentures on two retentive anchors. In total, 42 implants were inserted in the anterior maxilla. The participants rated their satisfaction on their existing conventional dentures, 2 months after insertion of new conventional dentures and 2 months after insertion of implant-supported dentures. Thereby, patients responded to questionnaires capturing the oral health impact profile (OHIP) using visual analog scales. Seven domains (functional limitation, physical pain, psychological discomfort, physical, psychological and social disability and handicap) were assessed. Higher scores implied poorer patient satisfaction. In addition, the questionnaire involved the evaluation of cleaning ability, general satisfaction, speech, comfort, esthetics, stability, and chewing ability. Higher scores implied higher patient satisfaction. RESULTS Patient satisfaction significantly increased for implant-supported dentures compared with old dentures in all seven OHIP subgroups, as well as for cleaning ability, general satisfaction, ability to speak, comfort, esthetics, and stability (P < 0.05). The comparison of new conventional dentures and implant-supported dentures revealed a statistically significantly increased satisfaction for functional limitation (difference of 33.2 mm), psychological discomfort (difference of 36.7 mm), physical disability (difference of 36.3 mm), and social disability (difference of 23.5 mm), (P < 0.05). Additionally, general satisfaction, chewing ability, speech, and stability significantly improved in implant-supported dentures (P < 0.05). CONCLUSIONS Within the limits of this study, maxillary dentures retained by two implants provided some significant short-term improvements over conventional dentures in oral- and health-related quality of life.
Prediction of dental implant torque with a fast and automatic finite element analysis: a pilot study
Resumo:
Despite its importance, implant removal torque can be assessed at present only after implantation. This paper presents a new technique to help clinicians preoperatively evaluate implant stability.
Resumo:
Abstract Objectives: To investigate the influence of protein incorporation on the resistance of biomimetic calcium-phosphate coatings to the shear forces that are generated during implant insertion. Materials and Methods: Thirty-eight standard (5 x 13 mm) Osseotite((R)) implants were coated biomimetically with a layer of calcium phosphate, which either lacked or bore a co-precipitated (incorporated) depot of the model protein bovine serum albumin (BSA). The coated implants were inserted into either artificial bone (n=18) or the explanted mandibles of adult pigs (n=12). The former set-up was established for the measurement of torque and of coating losses during the insertion process. The latter set-up was established for the histological and histomorphometric analysis of the fate of the coatings after implantation. Results: BSA-bearing coatings had higher mean torque values than did those that bore no protein depot. During the insertion process, less material was lost from the former than from the latter type of coating. The histological and histomorphometric analysis revealed fragments of material to be sheared off from both types of coating at vulnerable points, namely, at the tips of the threads. The sheared-off fragments were retained within the peri-implant space. Conclusion: The incorporation of a protein into a biomimetically prepared calcium-phosphate coating increases its resistance to the shear forces that are generated during implant insertion. In a clinical setting, the incorporated protein would be an osteogenic agent, whose osteoinductive potential would not be compromised by the shearing off of coating material, and the osteoconductivity of an exposed implant surface would not be less than that of a coated one. To cite this article: Hägi TT, Enggist L, Michel D, Ferguson SJ, Liu Y, Hunziker EB. Mechanical insertion properties of calcium-phosphate implant coatings. Clin. Oral Impl. Res. xx, 2010; 000-000. doi: 10.1111/j.1600-0501.2010.01916.x.
Resumo:
OBJECTIVES: To determine (1) the optimal sites for mini-implant placement in the maxilla and the mandible based on dimensional mapping of the interradicular spaces and cortical bone thickness and (2) The effect of age and sex on the studied anatomic measurements. MATERIAL AND METHODS: The cone beam computed tomography images of 100 patients (46 males, 54 females) divided into two age groups (13-18 years), and (19-27 years) were used. The following interradicular measurements were performed: (1) Buccolingual bone thickness; (2) Mesiodistal spaces both buccally and palatally/lingually; and (3) Buccal and palatal/lingual cortical thicknesses. RESULTS: In the maxilla, the highest buccolingual thickness existed between first and second molars; the highest mesiodistal buccal/palatal distances were between the second premolar and the first molar. The highest buccal cortical thickness was between the first and second premolars. The highest palatal cortical thickness was between central and lateral incisors. In the mandible, the highest buccolingual and buccal cortical thicknesses were between the first and second molars. The highest mesiodistal buccal distance was between the second premolar and the first molar. The highest mesiodistal lingual distance was between the first and second premolars. The highest lingual cortical thickness was between the canine and the first premolar. The males and the older age group had significantly higher buccolingual, buccal, and palatal cortical thicknesses at specific sites and levels in the maxilla and the mandible. CONCLUSIONS: A clinical guideline for optimal sites for mini-implant placement is suggested. Sex and age affected the anatomic measurements in certain areas in the maxilla and the mandible.
Resumo:
Early implant placement is one of the treatment options after tooth extraction. Implant surgery is performed after a healing period of 4 to 8 weeks and combined with a simultaneous contour augmentation using the guided bone regeneration technique to rebuild stable esthetic facial hard- and soft-tissue contours.
Resumo:
PURPOSE: The mandibular implant overdenture is a popular treatment modality and is well documented in the literature. Follow-up studies with a long observation period are difficult to perform due to the increasing age of patients. The present data summarize a long-term clinical observation of patients with implant overdentures. MATERIALS AND METHODS: Between 1984 and 1997, edentulous patients were consecutively admitted for treatment with an implant overdenture. The dentures were connected to the implants by means of bars or ball anchors. Regular maintenance was provided with at least one or two scheduled visits per year. Recall attendance and reasons for dropout were analyzed based on the specific history of the patient. Denture maintenance service, relining, repair, and fabrication of new dentures were identified, and complications with the retention devices specified separately. RESULTS: In the time period from 1984 to 2008, 147 patients with a total of 314 implants had completed a follow-up period of >10 years. One hundred one patients were still available in 2008, while 46 patients were not reexamined for various reasons. Compliance was high, with a regular recall attendance of >90%. More than 80% of dentures remained in continuous service. Although major prosthetic maintenance was rather low in relation to the long observation period, visits to a dental hygienist and dentist resulted in an annual visit rate of 1.5 and 2.4, respectively. If new dentures became necessary, these were made in student courses, which increased the treatment time and number of appointments needed. Complications with the retention devices consisted mostly of the mounting of new female retainers, the repair of bars, and the changing of ball anchors. The average number of events and the rate of prosthetic service with ball anchors were significantly higher than those with bars. Twenty-two patients changed from ball anchors to bars; 9 patients switched from a clip bar to a rigid U-shaped bar. CONCLUSIONS: This long-term follow-up study demonstrates that implant overdentures are a favorable solution for edentulous patients with regular maintenance. In spite of specific circumstances in an aging population, it is possible to provide long-term care, resulting in a good prognosis and low risk for this treatment modality. For various reasons the dropout rate can be considerable in elderly patients and prosthetic service must be provided regularly.
Resumo:
OBJECTIVES: The aim of this study was to compare the long-term outcomes of implants placed in patients treated for periodontitis periodontally compromised patients (PCP) and in periodontally healthy patients (PHP) in relation to adhesion to supportive periodontal therapy (SPT). MATERIAL AND METHODS: One hundred and twelve partially edentulous patients were consecutively enrolled in private specialist practice and divided into three groups according to their initial periodontal condition: PHP, moderate PCP and severe PCP. Perio and implant treatment was carried out as needed. Solid screws (S), hollow screws (HS) and hollow cylinders (HC) were installed to support fixed prostheses, after successful completion of initial periodontal therapy (full-mouth plaque score <25% and full-mouth bleeding score <25%). At the end of treatment, patients were asked to follow an individualized SPT program. At 10 years, clinical measures and radiographic bone changes were recorded by two calibrated operators, blinded to the initial patient classification. RESULTS: Eleven patients were lost to follow-up. During the period of observation, 18 implants were removed because of biological complications. The implant survival rate was 96.6%, 92.8% and 90% for all implants and 98%, 94.2% and 90% for S-implants only, respectively, for PHP, moderate PCP and severe PCP. The mean bone loss was 0.75 (+/- 0.88) mm in PHP, 1.14 (+/- 1.11) mm in moderate PCP and 0.98 (+/- 1.22) mm in severe PCP, without any statistically significant difference. The percentage of sites, with bone loss > or =3 mm, was, respectively, 4.7% for PHP, 11.2% for moderate PCP and 15.1% for severe PCP, with a statistically significant difference between PHP and severe PCP (P<0.05). Lack of adhesion to SPT was correlated with a higher incidence of bone loss and implant loss. CONCLUSION: Patients with a history of periodontitis presented a lower survival rate and a statistically significantly higher number of sites with peri-implant bone loss. Furthermore, PCP, who did not completely adhere to the SPT, were found to present a higher implant failure rate. This underlines the value of the SPT in enhancing the long-term outcomes of implant therapy, particularly in subjects affected by periodontitis, in order to control reinfection and limit biological complications.
Resumo:
To analyze the dimensions and anatomic characteristics of the nasopalatine canal and the corresponding buccal bone plate of the alveolar process, using limited cone-beam computed tomography (CBCT) imaging.