67 resultados para image processing and analysis

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

XMapTools is a MATLAB©-based graphical user interface program for electron microprobe X-ray image processing, which can be used to estimate the pressure–temperature conditions of crystallization of minerals in metamorphic rocks. This program (available online at http://www.xmaptools.com) provides a method to standardize raw electron microprobe data and includes functions to calculate the oxide weight percent compositions for various minerals. A set of external functions is provided to calculate structural formulae from the standardized analyses as well as to estimate pressure–temperature conditions of crystallization, using empirical and semi-empirical thermobarometers from the literature. Two graphical user interface modules, Chem2D and Triplot3D, are used to plot mineral compositions into binary and ternary diagrams. As an example, the software is used to study a high-pressure Himalayan eclogite sample from the Stak massif in Pakistan. The high-pressure paragenesis consisting of omphacite and garnet has been retrogressed to a symplectitic assemblage of amphibole, plagioclase and clinopyroxene. Mineral compositions corresponding to ~165,000 analyses yield estimates for the eclogitic pressure–temperature retrograde path from 25 kbar to 9 kbar. Corresponding pressure–temperature maps were plotted and used to interpret the link between the equilibrium conditions of crystallization and the symplectitic microstructures. This example illustrates the usefulness of XMapTools for studying variations of the chemical composition of minerals and for retrieving information on metamorphic conditions on a microscale, towards computation of continuous pressure–temperature-and relative time path in zoned metamorphic minerals not affected by post-crystallization diffusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pilot study to detect volume changes of cerebral structures in growth hormone (GH)-deficient adults treated with GH using serial 3D MR image processing and to assess need for segmentation prior to registration was conducted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the advent of high through-put sequencing (HTS), the emerging science of metagenomics is transforming our understanding of the relationships of microbial communities with their environments. While metagenomics aims to catalogue the genes present in a sample through assessing which genes are actively expressed, metatranscriptomics can provide a mechanistic understanding of community inter-relationships. To achieve these goals, several challenges need to be addressed from sample preparation to sequence processing, statistical analysis and functional annotation. Here we use an inbred non-obese diabetic (NOD) mouse model in which germ-free animals were colonized with a defined mixture of eight commensal bacteria, to explore methods of RNA extraction and to develop a pipeline for the generation and analysis of metatranscriptomic data. Applying the Illumina HTS platform, we sequenced 12 NOD cecal samples prepared using multiple RNA-extraction protocols. The absence of a complete set of reference genomes necessitated a peptide-based search strategy. Up to 16% of sequence reads could be matched to a known bacterial gene. Phylogenetic analysis of the mapped ORFs revealed a distribution consistent with ribosomal RNA, the majority from Bacteroides or Clostridium species. To place these HTS data within a systems context, we mapped the relative abundance of corresponding Escherichia coli homologs onto metabolic and protein-protein interaction networks. These maps identified bacterial processes with components that were well-represented in the datasets. In summary this study highlights the potential of exploiting the economy of HTS platforms for metatranscriptomics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Past research has shown that the gender typicality of applicants’ faces affects leadership selection irrespective of a candidate’s gender: A masculine facial appearance is congruent with masculine-typed leadership roles, thus masculine-looking applicants are hired more certainly than feminine-looking ones. In the present study, we extended this line of research by investigating hiring decisions for both masculine- and feminine-typed professional roles. Furthermore, we used eye tracking to examine the visual exploration of applicants’ portraits. Our results indicate that masculine-looking applicants were favored for the masculine-typed role (leader) and feminine-looking applicants for the feminine-typed role (team member). Eye movement patterns showed that information about gender category and facial appearance was integrated during first fixations of the portraits. Hiring decisions, however, were not based on this initial analysis, but occurred at a second stage, when the portrait was viewed in the context of considering the applicant for a specific job.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many countries treat income generated via exports favourably, especially when production takes places in special zones known as export processing zones (EPZs). EPZs can be defined as specific, geographically defined zones or areas that are subject to special administration and that generally offer tax incentives, such as duty‐free imports when producing for export, exemption from other regulatory constraints linked to import for the domestic market, sometimes favourable treatment in terms of industrial regulation, and the streamlining of border clearing procedures. We describe a database of WTO Members that employ special economic zones as part of their industrial policy mix. This is based on WTO notification and monitoring through the WTO’s trade policy review mechanism (TPRM), supplemented with information from the ILO, World Bank, and primary sources. We also provide some rough analysis of the relationship between use of EPZs and the carbon intensity of exports, and relative levels of investment across countries with and without special zones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the diagnostic accuracy, image quality, and radiation dose of an iterative reconstruction algorithm compared with a filtered back projection (FBP) algorithm for abdominal computed tomography (CT) at different tube voltages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To intraindividually compare a low-tube-voltage (80 kVp), high-tube-current (675 mA) computed tomographic (CT) technique with a high-tube-voltage (140 kVp) CT protocol for the detection of pancreatic tumors, image quality, and radiation dose during the pancreatic parenchymal phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To investigate whether an adaptive statistical iterative reconstruction (ASIR) algorithm improves the image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal computed tomography (CT) during the late hepatic arterial phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

http://www.ncbi.nlm.nih.gov/pubmed/20554796

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Java Enterprise Applications (JEAs) are large systems that integrate multiple technologies and programming languages. Transactions in JEAs simplify the development of code that deals with failure recovery and multi-user coordination by guaranteeing atomicity of sets of operations. The heterogeneous nature of JEAs, however, can obfuscate conceptual errors in the application code, and in particular can hide incorrect declarations of transaction scope. In this paper we present a technique to expose and analyze the application transaction scope in JEAs by merging and analyzing information from multiple sources. We also present several novel visualizations that aid in the analysis of transaction scope by highlighting anomalies in the specification of transactions and violations of architectural constraints. We have validated our approach on two versions of a large commercial case study.