23 resultados para household saving

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vaginal practices in sub-Saharan Africa may increase HIV transmission and have important implications for development of microbicides and future HIV prevention technologies. It remains unclear which women undertake vaginal practices and what factors predict prevalence, practice type and choice of products. Using cross-sectional data from mixed research methods, we identify factors associated with vaginal practices among women in KwaZulu-Natal, South Africa. Data were gathered through focus group discussions, in-depth and key-informant interviews, followed by a province-wide, multi-stage cluster household survey, using structured questionnaires in face-to-face interviews with 867 women. This paper details six types of vaginal practices, which--despite their individual distinctiveness and diverse motivations--may be clustered into two broad groups: those undertaken for purposes of 'hygiene' (genital washing, douching and application) and those for 'sexual motivations' (application, insertion, ingestion and incisions). Multivariate analysis found significant associations between 'hygiene' practices and media access, religiosity and transactional sex. 'Sexual' practices were associated with partner concurrency, religiosity and use of injectable hormonal contraceptives. Future interventions relating to vaginal practices as well as microbicides need to reflect this characterisation of practices as sexual- and/or hygiene-related.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Women worldwide use various vaginal practices to clean or modify their vulva and vagina. Additional population-level information is needed on prevalence and motivations for these practices, characteristics of users, and their adverse effects. Methods: This was a household survey using multistage cluster sampling in Tete, Mozambique; KwaZulu-Natal, South Africa; Yogyakarta, Indonesia; and Chonburi, Thailand. In 2006–2007, vaginal practices and their motivations were examined using structured interviews with women 18–60 years of age (n=3610). Results: Prevalence, frequency, and motivations varied markedly. Two thirds of women in Yogyakarta and Chonburi reported one or more practices. In Yogyakarta, nearly half ingest substances with vaginal effects, and in Chonburi, external washing and application predominate. In Tete, half reported three or four current practices, and a quarter reported five or more practices. Labial elongation was near universal, and 92% of those surveyed cleanse internally. Two third's in KwaZulu-Natal practiced internal cleansing. Insertion of traditional solid products was rare in Chonburi and Yogyakarta, but one tenth of women in KwaZulu-Natal and nearly two thirds of women in Tete do so. Multivariate analysis of the most common practice in each site showed these were more common among less educated women in Africa and young urban women in Asia. Explicit sexual motivations were frequent in KwaZulu-Natal and Tete, intended for pleasure and maintaining partner commitment. Practices in Chonburi and Yogyakarta were largely motivated by femininity and health. Genital irritation was common at African sites. Conclusions: Vaginal practices are not as rare, exotic, or benign as sometimes assumed. Limited evidence of their biomedical consequences remains a concern; further investigation of their safety and sexual health implications is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies about transmission rates of extended-spectrum β-lactamase (ESBL)-producing Enterobacteriaceae in hospitals and households are scarce.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Children in emergencies need peripheral intravenous (IV) access in order to receive drugs or fluids. The success of IV access is associated with the age of patients and fails in up to 50% of children younger than 6 years. In such situations, it is essential that physicians and paramedics have a tool and easily learnable skills with a high chance of success. According to international guidelines intraosseous (IO) access would be the next step after failed IV access. Our hypothesis was that the success rate in IO puncturing can be improved by standardizing the training; so we developed an IO workshop. METHODS: Twenty-eight hospitals and ambulance services participated in an evaluation process over 3 years. IO workshops and the distribution of standardized IO sets were coordinated by the study group of the University Hospital of Berne. Any attempted or successful IO punctures were evaluated with a standardized interview. RESULTS: We investigated 35 applications in 30 patients (a total of 49 punctures) between November 2001 and December 2004. IO puncture was not successful in 5 patients. The success rate depended neither on the occupation nor the experience of users. Attendance at a standardized IO workshop increased the overall success rate from 77% to 100%, which was statistically not significant (P = 0.074). CONCLUSIONS: Standardized training in IO puncturing seems to improve success more than previous experience and occupation of providers. However, we could not show a significant increase in success rate after this training. Larger supranational studies are needed to show a significant impact of teaching on rarely used emergency skills.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a technique for online compression of ECG signals using the Golomb-Rice encoding algorithm. This is facilitated by a novel time encoding asynchronous analog-to-digital converter targeted for low-power, implantable, long-term bio-medical sensing applications. In contrast to capturing the actual signal (voltage) values the asynchronous time encoder captures and encodes the time information at which predefined changes occur in the signal thereby minimizing the sensor's energy use and the number of bits we store to represent the information by not capturing unnecessary samples. The time encoder transforms the ECG signal data to pure time information that has a geometric distribution such that the Golomb-Rice encoding algorithm can be used to further compress the data. An overall online compression rate of about 6 times is achievable without the usual computations associated with most compression methods.