13 resultados para hole effective-mass Hamiltonian

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This Letter presents a search for quantum black-hole production using 20.3 fb(-1) of data collected with the ATLAS detector in pp collisions at the LHC at root s = 8 TeV. The quantum black holes are assumed to decay into a final state characterized by a lepton (electron or muon) and a jet. In either channel, no event with a lepton-jet invariant mass of 3.5 TeV or more is observed, consistent with the expected background. Limits are set on the product of cross sections and branching fractions for the lepton + jet final states of quantum black holes produced in a search region for invariant masses above 1 TeV. The combined 95% confidence level upper limit on this product for quantum black holes with threshold mass above 3.5 TeV is 0.18 fb. This limit constrains the threshold quantum black-hole mass to be above 5.3 TeV in the model considered.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Observable quantities in cosmology are dimensionless, and therefore independent of the units in which they are measured. This is true of all physical quantities associated with the primordial perturbations that source cosmic microwave background anisotropies such as their amplitude and spectral properties. However, if one were to try and infer an absolute energy scale for inflation—a priori, one of the more immediate corollaries of detecting primordial tensor modes—one necessarily makes reference to a particular choice of units, the natural choice for which is Planck units. In this note, we discuss various aspects of how inferring the energy scale of inflation is complicated by the fact that the effective strength of gravity as seen by inflationary quanta necessarily differs from that seen by gravitational experiments at presently accessible scales. The uncertainty in the former relative to the latter has to do with the unknown spectrum of universally coupled particles between laboratory scales and the putative scale of inflation. These intermediate particles could be in hidden as well as visible sectors or could also be associated with Kaluza–Klein resonances associated with a compactification scale below the scale of inflation. We discuss various implications for cosmological observables.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND For chronic subdural hematoma, placement of a Blake drain with a two-burr-hole craniotomy is often preferred. However, the placement of such drains carries the risk of penetrating the brain surface or damaging superficial venous structures. OBJECTIVE To describe the use of a Nelaton catheter for the placement of a subdural drain in two-burr-hole trephination for chronic subdural hematoma. METHOD A Nelaton catheter was used to guide placement of a Blake drain into the subdural hematoma cavity and provide irrigation of the hematoma cavity. With the two-burr-hole method, the Nelaton catheter could be removed easily via the frontal burr hole after the Blake drain was in place. RESULTS We used the Nelaton catheters in many surgical procedures and found it a safe and easy technique. This method allows the surgeon to safely direct the catheter into the correct position in the subdural space. CONCLUSIONS This tool has two advantages. First, the use of a small and flexible Nelaton catheter is a safe method for irrigation of a chronic subdural hematoma cavity. Second, in comparison with insertion of subdural drainage alone through a burr hole, the placement of the Nelaton catheter in subdural space is easier and the risk of damaging relevant structures such as cortical tissue or bridging veins is lower. Thus this technique may help to avoid complications when placing a subdural drain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Estimation of respiratory deadspace is often based on the CO2 expirogram, however presence of the CO2 sensor increases equipment deadspace, which in turn influences breathing pattern and calculation of lung volume. In addition, it is necessary to correct for the delay between the sensor and flow signals. We propose a new method for estimation of effective deadspace using the molar mass (MM) signal from an ultrasonic flowmeter device, which does not require delay correction. We hypothesize that this estimation is correlated with that calculated from the CO2 signal using the Fowler method. METHODS: Breath-by-breath CO2, MM and flow measurements were made in a group of 77 term-born healthy infants. Fowler deadspace (Vd,Fowler) was calculated after correcting for the flow-dependent delay in the CO2 signal. Deadspace estimated from the MM signal (Vd,MM) was defined as the volume passing through the flowhead between start of expiration and the 10% rise point in MM. RESULTS: Correlation (r = 0.456, P < 0.0001) was found between Vd,MM and Vd,Fowler averaged over all measurements, with a mean difference of -1.4% (95% CI -4.1 to 1.3%). Vd,MM ranged from 6.6 to 11.4 ml between subjects, while Vd,Fowler ranged from 5.9 to 12.0 ml. Mean intra-measurement CV over 5-10 breaths was 7.8 +/- 5.6% for Vd,MM and 7.8 +/- 3.7% for Vd,Fowler. Mean intra-subject CV was 6.0 +/- 4.5% for Vd,MM and 8.3 +/- 5.9% for Vd,Fowler. Correcting for the CO2 signal delay resulted in a 12% difference (P = 0.022) in Vd,Fowler. Vd,MM could be obtained more frequently than Vd,Fowler in infants with CLD, with a high variability. CONCLUSIONS: Use of the MM signal provides a feasible estimate of Fowler deadspace without introducing additional equipment deadspace. The simple calculation without need for delay correction makes individual adjustment for deadspace in FRC measurements possible. This is especially important given the relative large range of deadspace seen in this homogeneous group of infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the feasibility and effectiveness of a comprehensive outpatient rehabilitation program combining secondary prevention and neurorehabilitation to improve vascular risk factors, neurologic functions, and health-related quality of life (HRQOL) in patients surviving a transient ischemic attack (TIA) or stroke with minor or no residual deficits. Design Prospective interventional single-center cohort study. Setting University hospital. Participants Consecutive consenting patients having sustained a TIA or stroke with 1 or more vascular risk factors (N=105) were included. Interventions Three-month hospital-based secondary prevention and neurorehabilitation outpatient program with therapeutic and educational sessions twice a week. Patients were evaluated at entry and program end. Main Outcome Measures Impact on vascular risk factors, neurological outcome, and HRQOL. Results A total of 105 patients entered the program and 95 patients completed it. Exercise capacity (P<.000), smoking status (P=.001), systolic (P=.001) and diastolic (P=.008) blood pressure, body mass index (P=.005), low-density lipoprotein cholesterol (P=.03), and triglycerides (P=.001) improved significantly. Furthermore, the 9-Hole-Peg-Test (P<.000), Six-minute Walking Test (P<.000), and One Leg Stand Test (P<.011) values as well as HRQOL improved significantly. The program could be easily integrated into an existing cardiovascular prevention and rehabilitation center and was feasible and highly accepted by patients. Conclusions Comprehensive combined cardiovascular and neurologic outpatient rehabilitation is feasible and effective to improve vascular risk factors, neurologic functions, and HRQOL in patients surviving TIA or stroke with minor or no residual deficits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To assess macular hole surgery in patients with end-stage choroideremia with regard to anatomic closure and visual outcome. DESIGN Retrospective, interventional case series. PARTICIPANTS Thirty adult male patients with a diagnosis of advanced choroideremia were reviewed and underwent spectral domain optical coherence tomography (OCT) as part of the screening process for a gene therapy clinical trial. From within that cohort, 3 were identified as having a full-thickness macular hole (FTMH). METHODS A 23-gauge pars plana vitrectomy was performed with peeling of the inner limiting membrane and gas tamponade. Preoperative best-corrected visual acuity ranged from perception of light to 6/24. MAIN OUTCOME MEASURES Prevalence of FTMH in advanced choroideremia, morphologic phenotype characteristics of FTMH in OCT, pre- and postoperative best-corrected visual acuity, and closure rate after surgery. RESULTS The prevalence of FTMH in advanced choroideremia in our cohort was 10%. One hole was associated with significant macular schisis, presumed to be attributable to degeneration of outer retinal layers. Anatomic closure was achieved in all 3 patients and confirmed with spectral domain OCT. Gas tamponade lasted approximately twice as long as might be expected compared with standard FTMH surgery. Objective visual acuity did not improve; however, perceived vision improved in all patients. CONCLUSIONS Although FTMH in choroideremia is a rare finding, it could potentially mask central progression of the disease. Regular screening may help to diagnose holes at an earlier stage when the visual prognosis after surgery may be better. Standard macular hole surgery seems to be effective in gaining anatomic closure, which would be significant for patients who subsequently require macula detachment for subretinal gene therapy. FINANCIAL DISCLOSURE(S) The authors have no proprietary or commercial interest in any of the materials discussed in this article.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We study the strength of the electroweak phase transition in models with two light Higgs doublets and a light SU(3)c triplet by means of lattice simulations in a dimensionally reduced effective theory. In the parameter region considered the transition on the lattice is significantly stronger than indicated by a 2-loop perturbative analysis. Within some ultraviolet uncertainties, the finding applies to MSSM with a Higgs mass mh ≈ 126 GeV and shows that the parameter region useful for electroweak baryogenesis is enlarged. In particular (even though only dedicated analyses can quantify the issue), the tension between LHC constraints after the 7 TeV and 8 TeV runs and frameworks where the electroweak phase transition is driven by light stops, seems to be relaxed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We construct several classes of worldvolume effective actions for black holes by integrating out spatial sections of the worldvolume geometry of asymptotically flat black branes. This provides a generalisation of the blackfold approach for higher-dimensional black holes and yields a map between different effective theories, which we exploit by obtaining new hydrodynamic and elastic transport coefficients via simple integrations. Using Euclidean minimal surfaces in order to decouple the fluid dynamics on different sections of the worldvolume, we obtain local effective theories for ultraspinning Myers-Perry branes and helicoidal black branes, described in terms of a stress-energy tensor, particle currents and non-trivial boost vectors. We then study in detail and present novel compact and non-compact geometries for black hole horizons in higher-dimensional asymptotically flat space-time. These include doubly-spinning black rings, black helicoids and helicoidal p-branes as well as helicoidal black rings and helicoidal black tori in D ≥ 6.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Metallocene dichlorides constitute a remarkable class of antineoplastic agents that are highly effective against several cancer cell lines. They were shown to accumulate in the DNA-rich region, which suggests DNA as the primary target. These compounds exhibit two cyclopentadienyl ligands and two labile halide ligands, resulting in a bent sandwich structure. The cis-dihalide motif is structurally related to the cis-chloro configuration of cisplatin and similar modes of action can thus be assumed. Cisplatin binds to two neighboring guanine nucleobases in DNA and consequently, distorts the double-helix, thereby inhibiting DNA replication and transcription. Platinum is classified as a soft Lewis acid and binds preferentially to the nitrogen atoms within the nucleobases. The metallocene dichlorides investigated in this study comprise the metal centers Ti, V, Nb, Mo, Hf, and W, which are classified as hard or intermediate Lewis acids, and thus, favor binding to the phosphate oxygen. Although several studies reported adduct formation of metallocene dichlorides with nucleic acids, substantial information about the adduct composition, the binding pattern, and the nucleobase selectivity has not been provided yet. ESI-MS analyses gave evidence for the formation of metallocene adducts (M = Ti, V, Mo, and W) with single-stranded DNA homologues at pH 7. No adducts were formed with Nb and Hf at neutral pH, albeit adducts with Nb were observed at a low pH. MS2 data revealed considerable differences of the adduct compositions. The product ion spectra of DNA adducts with hard Lewis acids (Ti, V) gave evidence for the loss of metallocene ligands and only moderate backbone fragmentation was observed. By contrast, adducts with intermediate Lewis acids (Mo, W) retained the hydroxy ligands. Preliminary results are in good agreement with the Pearson concept and DFT calculations. Since the metallodrugs were not lost upon CID, the nucleobase selectivity, stoichiometry, and binding patterns can be elucidated by means of tandem mass spectrometry.