66 resultados para hemodynamic instability
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND AND OBJECTIVES: Thoracic epidural analgesia (TEA) is increasingly used for perioperative analgesia. If patients with TEA develop sepsis or systemic inflammatory response subsequent to extended surgery the question arises if it would be safe to continue TEA with its beneficial effects of improving gastrointestinal perfusion and augmenting tissue oxygenation. A major concern in this regard is hemodynamic instability that might ensue from TEA-induced vasodilation. The objective of the present study was to assess the effects of TEA on systemic and pulmonary hemodynamics in a sepsis model of hyperdynamic endotoxemia. METHODS: After a baseline measurement in healthy sheep (n = 14), Salmonella thyphosa endotoxin was continuously infused at a rate of 10 ngxkg(-1)xmin(-1) over 16 hours. The surviving animals (n = 12) were then randomly assigned to 1 of 2 study groups. In the treatment group (n = 6), continuous TEA was initiated with 0.1 mLxkg(-1) bupivacaine 0.125% and maintained with 0.1 mLxkg(-1)xh(-1). In the control group (n = 6) the same amount of isotonic sodium saline solution was injected at the same rate through the epidural catheter. RESULTS: In both experimental groups cardiac index increased and systemic vascular resistance decreased concurrently (each P < .05). Functional epidural blockade in the TEA group was confirmed by sustained suppression of the cutaneous (or panniculus) reflex. During the observational period of 6 hours neither systemic nor pulmonary circulatory variables were impaired by TEA. CONCLUSIONS: From a hemodynamic point of view, TEA presents as a safe treatment option in sepsis or systemic inflammatory response syndrome.
Resumo:
Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.
Resumo:
An expert multidisciplinary panel in the treatment of type B aortic dissection reviewed available literature to develop treatment algorithms using a consensus method. Data from 63 studies published from 2006 to 2012 were retrieved for a total of 1,548 patients treated medically, 1,706 patients who underwent open surgery, and 3,457 patients who underwent thoracic endovascular repair (TEVAR). For acute (first 2 weeks) type B aortic dissection, the pooled early mortality rate was 6.4% with medical treatment and increased to 10.2% with TEVAR and 17.5% with open surgery, mostly for complicated cases. Limited data for treatment of subacute (2 to 6 weeks after onset) type B aortic dissection showed an early mortality rate of 2.8% with TEVAR. In chronic (after 6 weeks) type B aortic dissection, 5-year survival of 60% to 80% was expected with medical therapy because complications were likely. If interventional treatment was applied, the pooled early mortality rate was 6.6% with TEVAR and 8.0% with open surgery. Medical treatment of uncomplicated acute, subacute, and chronic type B aortic dissection is managed with close image monitoring. Hemodynamic instability, organ malperfusion, increasing periaortic hematoma, and hemorrhagic pleural effusion on imaging identify patients with complicated acute type B aortic dissection requiring urgent aortic repair. Recurrence of symptoms, aortic aneurysmal dilation (>55 mm), or a yearly increase of >4 mm after the acute phase are predictors of adverse outcome and need for delayed aortic repair ("complicated chronic aortic dissections"). The expert panel is aware that this consensus document provides proposal for strategies based on nonrobust evidence for management of type B aortic dissection, and that literature results were largely heterogeneous and should be interpreted cautiously.
Resumo:
OBJECTIVES: To evaluate the early prognostic value of the medical emergency team (MET) calling criteria in patients admitted to intensive care from the emergency department. DESIGN: Retrospective cohort study. SETTING: Emergency department and department of intensive care medicine of a 960-bed tertiary referral hospital. PATIENTS: A total of 452 consecutive adult patients admitted to intensive care from the emergency department from January 1, 2004, to December 31, 2004. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: MET calling criteria were retrospectively extracted from patient records, and the sum of positive criteria was calculated for the first hour in the emergency department (METinitial) and subsequently until admission to the intensive care unit in a series of time periods. The maximum number of positive MET calling criteria during any time period was defined (METmax). Logistic regression analysis revealed METinitial (odds ratio [OR] 3.392, 95% confidence interval [CI] 2.534-4.540) and METmax (OR 3.867, 95% CI 2.816-5.312) to be significant predictors of hospital mortality, the need for mechanical ventilation (METinitial: OR 4.151, 95% CI 3.53-4.652; METmax: OR 4.292, 95% CI 3.151-5.846), and occurrence of hemodynamic instability (METinitial: OR 1.548, 95% CI 1.258-1.905; METmax: OR 1.685, 95% CI 1.355-2.094) (all p < .0001). CONCLUSIONS: MET scores collected early after admission or throughout the stay in the emergency department allow for simple identification of patients at risk of unfavorable outcome during the subsequent intensive care unit stay.
Resumo:
ABSTRACT: BACKGROUND: Pelvic x-ray is a routine part of the primary survey of polytraumatized patients according to Advanced Trauma Life Support (ATLS) guidelines. However, pelvic CT is the gold standard imaging technique in the diagnosis of pelvic fractures. This study was conducted to confirm the safety of a modified ATLS algorithm omitting pelvic x-ray in hemodynamically stable polytraumatized patients with clinically stable pelvis in favour of later pelvic examination by CT scan. METHODS: We conducted a retrospective analysis of all polytraumatized patients in our emergency room between 01.07.2004 and 31.01.2006. Inclusion criteria were blunt abdominal trauma, initial hemodynamic stability and a stable pelvis on clinical examination. We excluded patients requiring immediate intervention because of hemodynamic instability. RESULTS: We reviewed the records of n = 452 polytraumatized patients, of which n = 91 fulfilled inclusion criteria (56% male, mean age = 45 years). The mechanism of trauma included 43% road traffic accidents, 47% falls. In 68/91 (75%) patients, both a pelvic x-ray and a CT examination were performed; the remainder had only pelvic CT. In 6/68 (9%) patients, pelvic fracture was diagnosed by pelvic x-ray. None of these 6 patients was found having a false positive pelvic x-ray, i.e. there was no fracture on pelvic CT scan. In 3/68 (4%) cases a fracture was missed in the pelvic x-ray, but confirmed on CT (false negative on x-ray). None of the diagnosed fractures needed an immediate therapeutic intervention. 5 (56%) were classified type A fractures, and another 4 (44%) B 2.1 in computed tomography (AO classification). One A 2.1 fracture was found in a clinically stable patient who only received CT scan (1/23). CONCLUSION: While pelvic x-ray is an integral part of ATLS assessment, this retrospective study suggests that in hemodynamically stable patients with clinically stable pevis, its sensitivity is only 67% and it may safely be omitted in favor of a pelvic CT examination if such is planned in adjunct assessment and available. The results support the safety and utility of our modified ATLS algorithm. A randomized controlled trial using the algorithm can safely be conducted to confirm the results.
Resumo:
OBJECT: Preliminary experience with the C-Port Flex-A Anastomosis System (Cardica, Inc.) to enable rapid automated anastomosis has been reported in coronary artery bypass surgery. The goal of the current study was to define the feasibility and safety of this method for high-flow extracranial-intracranial (EC-IC) bypass surgery in a clinical series. METHODS: In a prospective study design, patients with symptomatic carotid artery (CA) occlusion were selected for C-Port-assisted high-flow EC-IC bypass surgery if they met the following criteria: 1) transient or moderate permanent symptoms of focal ischemia; 2) CA occlusion; 3) hemodynamic instability; and 4) had provided informed consent. Bypasses were done using a radial artery graft that was proximally anastomosed to the superficial temporal artery trunk, the cervical external, or common CA. All distal cerebral anastomoses were performed on M2 branches using the C-Port Flex-A system. RESULTS: Within 6 months, 10 patients were enrolled in the study. The distal automated anastomosis could be accomplished in all patients; the median temporary occlusion time was 16.6+/-3.4 minutes. Intraoperative digital subtraction angiography (DSA) confirmed good bypass function in 9 patients, and in 1 the anastomosis was classified as fair. There was 1 major perioperative complication that consisted of the creation of a pseudoaneurysm due to a hardware problem. In all but 1 case the bypass was shown to be patent on DSA after 7 days; furthermore, in 1 patient a late occlusion developed due to vasospasm after a sylvian hemorrhage. One-week follow-up DSA revealed transient asymptomatic extracranial spasm of the donor artery and the radial artery graft in 1 case. Two patients developed a limited zone of infarction on CT scanning during the follow-up course. CONCLUSIONS: In patients with symptomatic CA occlusion, C-Port Flex-A-assisted high-flow EC-IC bypass surgery is a technically feasible procedure. The system needs further modification to achieve a faster and safer anastomosis to enable a conclusive comparison with standard and laser-assisted methods for high-flow bypass surgery.
Resumo:
BACKGROUND: Untreated hypovolemia results in impaired outcome. This study tests our hypothesis whether general hemodynamic parameters detect acute blood loss earlier than monitoring parameters of regional tissue beds. MATERIALS AND METHODS: Eight pigs (23-25 kg) were anesthetized and mechanically ventilated. A pulmonary artery catheter and an arterial catheter were inserted. Tissue oxygen tension was measured with Clark-type electrodes in the jejunal and colonic wall, in the liver, and subcutaneously. Jejunal microcirculation was assessed by laser Doppler flowmetry (LDF). Intravascular volume was optimized using difference in pulse pressure (dPP) to keep dPP below 13%. Sixty minutes after preparation, baseline measurements were taken. At first, 5% of total blood volume was withdrawn, followed by another 5% increment, and then in 10% increments until death. RESULTS: After withdrawal of 5% of estimated blood volume, dPP increased from 6.1% +/- 3.0% to 20.8% +/- 2.7% (P < 0.01). Mean arterial pressure (MAP), mean pulmonary artery pressure (PAP) and pulmonary artery occlusion pressure (PAOP) decreased with a blood loss of 10% (P < 0.01). Cardiac output (CO) changed after a blood loss of 20% (P < 0.05). Tissue oxygen tension in central organs, and blood flow in the jejunal muscularis decreased (P < 0.05) after a blood loss of 20%. Tissue oxygen tension in the skin, and jejunal mucosa blood flow decreased (P < 0.05) after a blood loss of 40% and 50%, respectively. CONCLUSIONS: In this hemorrhagic pig model systemic hemodynamic parameters were more sensitive to detect acute hypovolemia than tissue oxygen tension measurements or jejunal LDF measurements. Acute blood loss was detected first by dPP.
Resumo:
Pulse-pressure variation (PPV) due to increased right ventricular afterload and dysfunction may misleadingly suggest volume responsiveness. We aimed to assess prediction of volume responsiveness with PPV in patients with increased pulmonary artery pressure.
Resumo:
Currently, few data exist on the association between post-cardiac arrest hemodynamic function and outcome. In this explorative, retrospective analysis, the association between hemodynamic variables during the first 24 h after intensive care unit admission and functional outcome at day 28 was evaluated in 153 normothermic comatose patients following a cardiac arrest.
Resumo:
The conventional surgical aortic bioprostheses used for treatment of aortic stenosis (AS) are inherently stenotic in nature. The more favorable mechanical profile of the Medtronic CoreValve bioprosthesis may translate into a better hemodynamic and neurohormonal response.
Resumo:
Introduction: As a previous study revealed, arts speech therapy (AST) affects cardiorespiratory interaction [1]. The aim of the present study was to investigate whether AST also has effects on brain oxygenation and hemodynamics measured non-invasively using near-infrared spectroscopy (NIRS). Material and methods: NIRS measurements were performed on 17 subjects (8 men and 9 women, mean age: 35.6 ± 12.7 y) during AST. Each measurement lasted 35 min, comprising 8 min pre-baseline, 10 min recitation and 20 min post-baseline. For each subject, measurements were performed for three different AST recitation tasks (recitation of alliterative, hexameter and prose verse). Relative concentration changes of oxyhemoglobin (Δ[O2Hb]) and deoxyhemoglobin (Δ[HHb]) as well as the tissue oxygenation index (TOI) were measured using a Hamamatsu NIRO300 NIRS device and a sensor placed on the subjects forehead. Movement artifacts were removed using a novel method [2]. Statistical analysis (Wilcoxon test) was applied to the data to investigate (i) if the recitation causes changes in the median values and/or in the Mayer wave power spectral density (MW-PSD, range: 0.07–0.13 Hz) of Δ[O2Hb], Δ[HHb] or TOI, and (ii) if these changes vary between the 3 recitation forms. Results: For all three recitation styles a significant (p < 0.05) decrease in Δ[O2Hb] and TOI was found, indicating a decrease in blood flow. These decreases did not vary significantly between the three styles. MW-PSD increased significantly for Δ[O2Hb] when reciting the hexameter and prose verse, and for Δ[HHb] and TOI when reciting alliterations and hexameter, representing an increase in Mayer waves. The MW-PSD increase for Δ[O2Hb] was significantly larger for the hexameter verse compared to alliterative and prose verse Conclusion: The study showed that AST affects brain hemodynamics (oxygenation, blood flow and Mayer waves). Recitation caused a significant decrease in cerebral blood flow for all recitation styles as well as an increase in Mayer waves, particularly for the hexameter, which may indicate a sympathetic activation. References 1. D. Cysarz, D. von Bonin, H. Lackner, P. Heusser, M. Moser, H. Bettermann. Am J Physiol Heart Circ Physiol, 287 (2) (2004), pp. H579–H587 2. F. Scholkmann, S. Spichtig, T. Muehlemann, M. Wolf. Physiol Meas, 31 (5) (2010), pp. 649–662