15 resultados para heavy ion beam

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The recrystallization behavior of Cu films electrodeposited under oscillatory conditions in the presence of plating additives was studied by means of secondary ion mass spectrometry (SIMS) and focused ion beam analysis. When combined with bis-(sodium-sulfopropyl)-disulfide (SPS), Imep levelers (polymerizates of imidazole and epichlorohydrin) show characteristic oscillations in the galvanostatic potential/time transient measurements. These are related to the periodic degradation and restoration of the active leveler ensemble at the interface. The leveler action relies on adduct formation between the Imep and MPS (mercaptopropane sulfonic acid)-stabilized CuI complexes that appear as intermediates of the copper deposition when SPS is present in the electrolyte. SIMS depth profiling proves that additives are incorporated into the growing film preferentially under transient conditions during the structural breakdown of the leveler ensemble and its subsequent restoration. In contrast, Cu films electrodeposited in the presence of a structurally intact Imep–CuI–MPS ensemble remain largely contamination free.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fission fragment mass distributions were measured in heavy-ion induced fission of 238U. The mass distributions changed drastically with incident energy. The results are explained by a change of the ratio between fusion and quasifission with nuclear orientation. A calculation based on a fluctuation dissipation model reproduced the mass distributions and their incident energy dependence. Fusion probability was determined in the analysis. Evaporation residue cross sections were calculated with a statistical model for the reactions of 30Si+238U and 34S+238U using the obtained fusion probability in the entrance channel. The results agree with the measured cross sections of 263,264Sg and 267,268Hs, produced by 30Si+238U and 34S+238U, respectively. It is also suggested that sub-barrier energies can be used for heavy element synthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Parylenes are poly(p-xylylene) polymers that are widely used as moisture barriers and in biomedicine because of their good biocompatibility. We have investigated MeV ion beam lithography using 16O+ ions for writing defined patterns in Parylene-C, which is evaluated as a coating material for the Cochlear Implant (CI) electrode array, a neuroprosthesis to treat some forms of deafness. Parylene-C and -F on silicon and glass substrates as well as 50 μm thick PTFE were irradiated to different fluences (1×1013-1×10161×1013-1×1016 1 MeV 16O+ ions cm−2) through aperture masks under high vacuum and a low pressure (<10−3 mbar) oxygen atmosphere. Biocompatibility of the irradiated and unirradiated surfaces was tested by cell-counting to determine the proliferation of murine spiral ganglion cells. The results reveal that an oxygen ion beam can be used to pattern Parylene-C and -F without using a liquid solvent developer in a similar manner to PTFE but with a ∼25× smaller removal rate. Biocompatibility tests showed no difference in cell adhesion between irradiated and unirradiated areas or ion fluence dependence. Coating the Parylene surface with an adhesion-promoting protein mixture had a much greater effect on cell proliferation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A detector based on doped silica and optical fibers was developed to monitor the profile of particle accelerator beams of intensity ranging from 1 pA to tens of µA. Scintillation light produced in a fiber moving across the beam is measured, giving information on its position, shape and intensity. The detector was tested with a continuous proton beam at the 18 MeV Bern medical cyclotron used for radioisotope production and multi-disciplinary research. For currents from 1 pA to 20 µA, Ce3+ and Sb3+ doped silica fibers were used as sensors. Read out systems based on photodiodes, photomultipliers and solid state photomultipliers were employed. Profiles down to the pA range were measured with this method for the first time. For currents ranging from 1 pA to 3 µA, the integral of the profile was found to be linear with respect to the beam current, which can be measured by this detector with an accuracy of ∼1%. The profile was determined with a spatial resolution of 0.25 mm. For currents ranging from 5 µA to 20 µA, thermal effects affect light yield and transmission, causing distortions of the profile and limitations in monitoring capabilities. For currents higher than ∼1 µA, non doped optical fibers for both producing and transporting scintillation light were also successfully employed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The thermal release rate of nuclear reaction products was investigated in offline annealing experiments. This work was motivated by the search for a high melting catcher material for recoiling products from heavy ion induced nuclear fusion reactions. Polycrystalline refractory metal foils of Ni, Y, Zr, Nb, Mo, Hf, W, and Re were investigated as catcher metals. Diffusion data for various tracer/host combinations were deduced from the measured release rates. This work focuses on the diffusion and the release rate of volatile p-elements from row 5 and 6 of the periodic table as lighter homologues of the superheavy elements with Z ≥ 113 to be studied in future experiments. A massive radiation damage enhancement of the diffusion velocity was observed. Diffusion trends have been established along the groups and rows of the periodic table based on the dependence of diffusion velocity on atomic sizes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The European Rosetta mission on its way to comet 67P/Churyumov-Gerasimenko will remain for more than a year in the close vicinity (1 km) of the comet. The two ROSINA mass spectrometers on board Rosetta are designed to analyze the neutral and ionized volatile components of the cometary coma. However, the relative velocity between the comet and the spacecraft will be minimal and also the velocity of the outgassing particles is below 1km∕s. This combination leads to very low ion energies in the surrounding plasma of the comet, typically below 20eV. Additionally, the spacecraft may charge up to a few volts in this environment. In order to simulate such plasma and to calibrate the mass spectrometers, a source for ions with very low energies had to be developed for the use in the laboratory together with the different gases expected at the comet. In this paper we present the design of this ion source and we discuss the physical parameters of the ion beam like sensitivity, energy distribution, and beam shape. Finally, we show the first ion measurements that have been performed together with one of the two mass spectrometers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We demonstrate a reliable microfabrication process for a combined atomic force microscopy (AFM) and scanning electrochemical microscopy (SECM) measurement tool. Integrated cone-shaped sensors with boron doped diamond (BDD) or gold (Au) electrodes were fabricated from commercially available AFM probes. The sensor formation process is based on mature semiconductor processing techniques, including focused ion beam (FIB) machining, and highly selective reactive ion etching (RIE). The fabrication approach preserves the geometry of the original AFM tips resulting in well reproducible nanoscaled sensors. The feasibility and functionality of the fully featured tips are demonstrated by cyclic voltammetry, showing good agreement between the measured and calculated currents of the cone-shaped AFM-SECM electrodes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The quark-gluon plasma formed in heavy ion collisions contains charged chiral fermions evolving in an external magnetic field. At finite density of electric charge or baryon number (resulting either from nuclear stopping or from fluctuations), the triangle anomaly induces in the plasma the Chiral Magnetic Wave (CMW). The CMW first induces a separation of the right and left chiral charges along the magnetic field; the resulting dipolar axial charge density in turn induces the oppositely directed vector charge currents leading to an electric quadrupole moment of the quark-gluon plasma. Boosted by the strong collective flow, the electric quadrupole moment translates into the charge dependence of the elliptic flow coefficients, so that $v_2(\pi^+) < v_2(\pi^-)$ (at positive net charge). Using the latest quantitative simulations of the produced magnetic field and solving the CMW equation, we make further quantitative estimates of the produced $v_2$ splitting and its centrality dependence. We compare the results with the available experimental data.