6 resultados para glenoid

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although loosening of cemented glenoid components is one of the major complications of total shoulder arthroplasty, there is little information about factors affecting initial fixation of these components in the scapular neck. This study was performed to assess the characteristics of structural fixation of pegged glenoid components, if inserted with two different recommended cementing techniques. Six fresh-frozen shoulder specimens and two types of glenoid components were used. The glenoids were prepared according to the instructions and with the instrumentation of the manufacturer. In 3 specimens, the bone cement was inserted into the peg receiving holes (n = 12) and applied to the back surface of the glenoid component with a syringe. In the other 3 specimens, the cement was inserted into the holes (n = 15) by use of pure finger pressure: no cement was applied on the backside of the component. Micro-computed tomography scans with a resolution of 36 microm showed an intact cement mantle around all 12 pegs (100%) when a syringe was used. An incomplete cement plug was found in 7 of 15 pegs (47%) when the finger-pressure technique was used. Cement penetration into the cancellous bone was deeper in osteopenic bone. Application of bone cement on the backside of the glenoid prosthesis improved seating by filling out small spaces between bone and polyethylene resulting from irregularities after reaming or local cement extrusion from a drill hole. The fixation of a pegged glenoid component is better if the holes are filled with cement under pressure by use of a syringe and if cement is applied to the back of the glenoid component than if cement is inserted with pure finger pressure and no cement is applied to the back surface of the component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine whether changes in glenoid version are associated with humeral head displacement and changes in the joint reaction forces, as these might contribute to instability or loosening in total shoulder replacement. A total shoulder prosthesis was implanted in neutral version in 6 cadaveric shoulders. Glenoid version was then changed in steps of 4 degrees toward more anteversion and retroversion. An increase in anteversion resulted in anterior translation of the humeral head and in eccentric loading of the anterior part of the glenoid. Retroversion was associated with posterior displacement and posterior loading of the glenoid. A change in rotation of the humeral component did not compensate for altered version of the glenoid component. These results suggest that both instability and glenoid component loosening may be related to the version of the glenoid component. Therefore, assessment of loosening and instability justifies precise assessment of glenoid component version.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Factors predisposing to tearing of the rotator cuff are poorly understood. We have observed that the acromion of patients with a rotator cuff tear very often appears large on anteroposterior radiographs or during surgery. The purpose of this study was to quantify the lateral extension of the acromion in patients with a full-thickness rotator cuff tear and in patients with an intact rotator cuff. METHODS: The lateral extension of the acromion was assessed on true anteroposterior radiographs made with the arm in neutral rotation. The distance from the glenoid plane to the lateral border of the acromion was divided by the distance from the glenoid plane to the lateral aspect of the humeral head to calculate the acromion index. This index was determined in a group of 102 patients (average age, 65.0 years) with a proven full-thickness rotator cuff tear, in an age and gender-matched group of forty-seven patients (average age, 63.7 years) with osteoarthritis of the shoulder and an intact rotator cuff, and in an age and gender-matched control group of seventy volunteers (average age, 64.4 years) with an intact rotator cuff as demonstrated by ultrasonography. RESULTS: The average acromion index (and standard deviation) was 0.73 +/- 0.06 in the shoulders with a full-thickness tear, 0.60 +/- 0.08 in those with osteoarthritis and an intact rotator cuff, and 0.64 +/- 0.06 in the asymptomatic, normal shoulders with an intact rotator cuff. The difference between the index in the shoulders with a full-thickness supraspinatus tear and the index in those with an intact rotator cuff was highly significant (p < 0.0001). CONCLUSIONS: A large lateral extension of the acromion appears to be associated with full-thickness tearing of the rotator cuff.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The radical changes in prosthetic design made in the mid 1980s transformed the historically poorly performing reverse ball-and-socket total shoulder prosthesis into a highly successful salvage implant for pseudoparalytic, severely rotator cuff-deficient shoulders. Moving the center of rotation more medial and distal as well as implanting a large glenoid hemisphere that articulates with a humeral cup in 155 degrees of valgus are the biomechanical keys to sometimes spectacular short- to mid-term results. Use of the reverse total shoulder arthroplasty device allows salvage of injuries that previously were beyond surgical treatment. However, this technique has a complication rate approximately three times that of conventional arthroplasty. Radiographic and clinical results appear to deteriorate over time. Proper patient selection and attention to technical details are needed to reduce the currently high complication rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The critical shoulder angle combines the acromion index and glenoid inclination and has potential to discriminate between shoulders at risk for rotator cuff tear or osteoarthritis and those that are asymptomatic. However, its biomechanics, and particularly the role of the glenoid inclination, are not yet fully understood. METHODS A shoulder simulator was used to analyze the independent influence of glenoid inclination during abduction from 0 to 60°. Spindle motors transferred tension forces by a cable-pulley on human cadaveric humeri. A six-degree-of-freedom force transducer was mounted directly behind the polyethylene glenoid to measure shear and compressive joint reaction force and calculate the instability ratio (ratio of shear and compressive joint reaction force) with the different force ratios of the deltoid and supraspinatus muscles (2:1 and 1:1). A stepwise change in the inclination by 5° increments allowed simulation of a critical shoulder angle range of 20° to 45°. FINDINGS Tilting the glenoid to cranial (increasing the critical shoulder angle) increases the shear joint reaction force and therefore the instability ratio. A balanced force ratio (1:1) between the deltoid and the supraspinatus allowed larger critical shoulder angles before cranial subluxation occurred than did the deltoid-dominant ratio (2:1). INTERPRETATION Glenoid inclination-dependent changes of the critical shoulder angle have a significant impact on superior glenohumeral joint stability. The increased compensatory activity of the rotator cuff to keep the humeral head centered may lead to mechanical overload and could explain the clinically observed association between large angles and degenerative rotator cuff tears.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hintergrund Begleitverletzungen können in bis zu 90 % der Fälle nach erstmaliger Schulterluxation auftreten. Auch wenn sie nicht immer einen Einfluss auf die Therapiewahl haben, so ist eine sorgfältige Diagnostik entscheidend. Einteilung In der Akutsituation ist eine konventionelle Bildgebung in mindestens 2 Ebenen (a.-p./Neer/evtl. axial) vor und nach Reposition zwingend. Luxationsfrakturen dürfen nicht übersehen bzw. durch das Manöver der geschlossenen Reposition sekundär disloziert werden. Bestehen ossäre glenoidale, humerale oder kombinierte Verletzungen, sollten sie gemäß Stabilitätskriterien versorgt werden. Dies kann umgehend, nach manifester Dezentrierung oder Instabilität entweder mittels Osteosythese oder als glenohumerale Stabilisation im Verlauf erfolgen. Bei einer Instabilität ist prinzipiell zur Bilanzierung einer ossären Ursache das Arthro-CT die Untersuchung der Wahl, welche auch eine Beurteilung der kapsulolabroligamentären Verletzung sowie einer traumatischen Rotatorenmanschettenläsion ermöglicht. Letztere ist jedoch besser mittels Arthro-MRT zu beurteilen. Diskussion Eine signifikante frische, meist größere oder massive, Rotatorenmanschettenläsion sollte rasch operativ angegangen werden. Medial reichende „off the track“ Hill-Sachs-Läsionen können mittels einer Hill-Sachs-Remplissage oder, wie auch glenoidale Defekte, mittels einer Kochenaugmentation versorgt werden. Langzeitresultate des Latarjet-Verfahrens zeigen 25 Jahre nach dem Eingriff die niedrigste Reluxationsrate < 4 %, eine gute Außenrotation, eine sehr hohe Patientenzufriedenheit und degenerative Veränderungen, welche vergleichbar mit der natürlichen Entwicklung nach erstmaliger Schulterluxation ohne Rezidiv sind.