7 resultados para gamma detection

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To analyse the performance of a new M. tuberculosis-specific interferon gamma (IFNgamma) assay in patients with chronic inflammatory diseases who receive immunosuppressive drugs, including tumour necrosis factor alpha (TNFalpha) inhibitors. METHODS: Cellular immune responses to the M. tuberculosis-specific antigens ESAT-6, CFP-10, TB7.7 were prospectively studied in 142 consecutive patients treated for inflammatory rheumatic conditions. Results were compared with tuberculin skin tests (TSTs). Association of both tests with risk factors for latent M. tuberculosis infection (LTBI) and BCG vaccination were determined and the influence of TNFalpha inhibitors, corticosteroids, and disease modifying antirheumatic drugs (DMARDs) on antigen-specific and mitogen-induced IFNgamma secretion was analysed. RESULTS: 126/142 (89%) patients received immunosuppressive therapy. The IFNgamma assay was more closely associated with the presence of risk factors (odds ratio (OR) = 23.8 (95% CI 5.14 to 110) vs OR = 2.77 (1.22 to 6.27), respectively; p = 0.009), but less associated with BCG vaccination than the TST (OR = 0.47 (95% CI 0.15 to 1.47) vs OR = 2.44 (0.74 to (8.01), respectively; p = 0.025). Agreement between the IFNgamma assay and TST results was low (kappa = 0.17; 95% CI 0.02 to 0.32). The odds for a positive IFNgamma assay strongly increased with increasing prognostic relevance of LTBI risk factors. Neither corticosteroids nor conventional DMARDs significantly affected IFNgamma responses, but the odds for a positive IFNgamma assay were decreased in patients treated with TNFalpha inhibitors (OR = 0.21 (95% CI 0.07 to 0.63), respectively; p = 0.006). CONCLUSIONS: These results demonstrate that the performance of the M. tuberculosis antigen-specific IFNgamma ELISA is better than the classic TST for detection of LTBI in patients receiving immunosuppressive therapy for treatment of systemic autoimmune disorders.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reactive nitrogen oxide species (RNOS) have been implicated as effector molecules in inflammatory diseases. There is emerging evidence that gamma-tocopherol (gammaT), the major form of vitamin E in the North American diet, may play an important role in these diseases. GammaT scavenges RNOS such as peroxynitrite by forming a stable adduct, 5-nitro-gammaT (NGT). Here we describe a convenient HPLC method for the simultaneous determination of NGT, alphaT, and gammaT in blood plasma and other tissues. Coulometric detection of NGT separated on a deactivated reversed-phase column was linear over a wide range of concentrations and highly sensitive (approximately 10 fmol detection limit). NGT extracted from blood plasma of 15-week-old Fischer 344 rats was in the low nM range, representing approximately 4% of gammaT. Twenty-four h after intraperitoneal injection of zymosan, plasma NGT levels were 2-fold higher compared to fasted control animals when adjusted to gammaT or corrected for total neutral lipids, while alpha- and gammaT levels remained unchanged. These results demonstrate that nitration of gammaT is increased under inflammatory conditions and highlight the importance of RNOS reactions in the lipid phase. The present HPLC method should be helpful in clarifying the precise physiological role of gammaT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At the research reactor Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) a new Prompt Gamma-ray Activation Analysis (PGAA) facility was installed. The instrument was originally built and operating at the spallation source at the Paul Scherrer Institute in Switzerland. After a careful re-design in 2004–2006, the new PGAA instrument was ready for operation at FRM II. In this paper the main characteristics and the current operation conditions of the facility are described. The neutron flux at the sample position can reach up 6.07×1010 [cm−2 s−1], thus the optimisation of some parameters, e.g. the beam background, was necessary in order to achieve a satisfactory analytical sensitivity for routine measurements. Once the optimal conditions were reached, detection limits and sensitivities for some elements, like for example H, B, C, Si, or Pb, were calculated and compared with other PGAA facilities. A standard reference material was also measured in order to show the reliability of the analysis under different conditions at this instrument.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A convenient and rapid method for the simultaneous determination by HPLC of 3-hydroxyanthranilic acid and the dimer derived by its oxidation, cinnabarinic acid, is described. Buffers or biological samples containing these two Trp metabolites were acidified to pH 2.0 and extracted with ethyl acetate with recoveries of 96.5 +/- 0.5 and 93.4 +/- 3.7% for 3-hydroxyanthranilic and cinnabarinic acid, respectively. The two compounds were separated on a reversed-phase (C18) column combined with ion-pair chromatography and detected photometrically or electrochemically. The method was applied successfully to biological systems in which formation of either 3-hydroxyanthranilic or cinnabarinic acid had been described previously. Thus, interferon-gamma-treated human peripheral blood mononuclear cells formed and released significant amounts of 3-hydroxyanthranilic acid into the culture medium and mouse liver nuclear fraction possessed high "cinnabarinic acid synthase" activity. In contrast, addition of 3-hydroxyanthranilic acid to human erythrocytes resulted in only marginal formation of cinnabarinic acid. We conclude that the method described is specific, sensitive, and suitable for the detection of the two Trp metabolites in biological systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In tuberculosis (TB), the risk of exposure is determined mainly by the proximity to and the hours of direct contact with an infectious patient. We describe the contact investigation after detection of an infectious form of TB in a military camp using an Interferon-g-Release-Assay (IGRA, QuantiFERON-TB Gold In Tube [QTF-GIT]) eight weeks after detection of the index case. INDEX PATIENT: The index patient presented with fever, cough and weight loss in the military hospital six weeks after entering the camp. TB was suspected and anti-tuberculous therapy given immediately. Subsequently, TB was microbiologically confirmed. METHODS: Four exposure groups were formed a priori based on the proximity and the hours of direct contact to the index case. 168 (95.5%) agreed to be investigated: - Group A: sharing the same dormitory (15 persons) - Group B: same platoon, but not sharing the dormitory (20 persons) - Group C: staff and patients of the military hospital (22 persons) - Group D: other three platoons and senior military staff (111 persons). RESULTS: 34 (20.2%) out of 168 contacts tested positive in the QFT-GIT assay. For the exposure groups, the respective QFT-GIT testing results were: group A, 14/15 (93%); group B, 4/20 (20%); group C, 5/22 (22.7%); and group D, 11/111 (9.9%). No secondary TB cases were identified. CONCLUSIONS: In our study, test results show a correlation with the risk of exposure, suggesting that IGRA may be useful for the assessment of TB infection in TB contacts. The high mobility of recruits reduced traceability of contacts. In this context, QFT-GIT allowed for an efficient screening of contacts at a single time point.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The most prevalent drug hypersensitivity reactions are T-cell mediated. The only established in vitro test for detecting T-cell sensitization to drugs is the lymphocyte transformation test, which is of limited practicability. To find an alternative in vitro method to detect drug-sensitized T cells, we screened the in vitro secretion of 17 cytokines/chemokines by peripheral blood mononuclear cells (PBMC) of patients with well-documented drug allergies, in order to identify the most promising cytokines/chemokines for detection of T-cell sensitization to drugs. METHODS: Peripheral blood mononuclear cell of 10 patients, five allergic to beta-lactams and five to sulfanilamides, and of five healthy controls were incubated for 3 days with the drug antigen. Cytokine concentrations were measured in the supernatants using commercially available 17-plex bead-based immunoassay kits. RESULTS: Among the 17 cytokines/chemokines analysed, interleukin-2 (IL-2), IL-5, IL-13 and interferon-gamma (IFN-gamma) secretion in response to the drugs were significantly increased in patients when compared with healthy controls. No difference in cytokine secretion patterns between sulfonamide- and beta-lactam-reactive PBMC could be observed. The secretion of other cytokines/chemokines showed a high variability among patients. CONCLUSION: The measurement of IL-2, IL-5, IL-13 or IFN-gamma or a combination thereof might be a useful in vitro tool for detection of T-cell sensitization to drugs. Secretion of these cytokines seems independent of the type of drug antigen and the phenotype of the drug reaction. A study including a higher number of patients and controls will be needed to determine the exact sensitivity and specificity of this test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Europe and the United States, the recreational use of gamma-hydroxy butyric acid (GHB) at dance clubs and "rave" parties has increased substantially. In addition, GHB is used to assist in the commission of sexual assaults. The aim of this controlled clinical study was to acquire pharmacokinetic profiles, detection times, and excretion rates in human subjects. Eight GHB-naïve volunteers were administered a single 25-mg/kg body weight oral dose of GHB, and plasma, urine, and oral fluid specimens were analyzed by using gas chromatography-mass spectrometry (GC-MS). Liquid-liquid extraction was performed after acid conversion of GHB to gamma-butyrolactone. Limits of quantitation of 0.1 (oral fluid), 0.2 (urine), and 0.5 microg/mL (plasma) could be achieved in the selected ion monitoring mode. GHB plasma peaks of 39.4 +/- 25.2 microg/mL (mean +/- SEM) occurred 20-45 min after administration. The terminal plasma elimination half-life was 30.4 +/- 2.45 min, the distribution volume 52.7 +/- 15.0 L, and the total clearance 1228 +/- 233 microL/min. In oral fluid, GHB could be detected up to 360 min, with peak concentrations of 203 +/- 92.4 microg/mL in the 10-min samples. In urine, 200 +/- 71.8 and 230 +/- 86.3 microg/mL, were the highest GHB levels measured at 30 and 60 min, respectively. Only 1.2 +/- 0.2% of the dose was excreted, resulting in a detection window of 720 min. Common side-effects were confusion, sleepiness, and dizziness; euphoria and change of vital functions were not observed. GHB is extensively metabolized and rapidly eliminated in urine and oral fluid. Consequently, samples should be collected as soon as possible after ingestion.