23 resultados para focal-plane-array image processors

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a conceptual prototype model of a focal plane array unit for the STEAMR instrument, highlighting the challenges presented by the required high relative beam proximity of the instrument and focus on how edge-diffraction effects contribute to the array's performance. The analysis was carried out as a comparative process using both PO & PTD and MoM techniques. We first highlight general differences between these computational techniques, with the discussion focusing on diffractive edge effects for near-field imaging reflectors with high truncation. We then present the results of in-depth modeling analyses of the STEAMR focal plane array followed by near-field antenna measurements of a breadboard model of the array. The results of these near-field measurements agree well with both simulation techniques although MoM shows slightly higher complex beam coupling to the measurements than PO & PTD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Defocus blur is an indicator for the depth structure of a scene. However, given a single input image from a conventional camera one cannot distinguish between blurred objects lying in front or behind the focal plane, as they may be subject to exactly the same amount of blur. In this paper we address this limitation by exploiting coded apertures. Previous work in this area focuses on setups where the scene is placed either entirely in front or entirely behind the focal plane. We demonstrate that asymmetric apertures result in unique blurs for all distances from the camera. To exploit asymmetric apertures we propose an algorithm that can unambiguously estimate scene depth and texture from a single input image. One of the main advantages of our method is that, within the same depth range, we can work with less blurred data than in other methods. The technique is tested on both synthetic and real images.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A laser scanning microscope collects information from a thin, focal plane and ignores out of focus information. During the past few years it has become the standard imaging method to characterise cellular morphology and structures in static as well as in living samples. Laser scanning microscopy combined with digital image restoration is an excellent tool for analysing the cellular cytoarchitecture, expression of specific proteins and interactions of various cell types, thus defining valid criteria for the optimisation of cell culture models. We have used this tool to establish and evaluate a three dimensional model of the human epithelial airway wall.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spreading the PSF over a quite large amount of pixels is an increasingly used observing technique in order to reach extremely precise photometry, such as in the case of exoplanets searching and characterization via transits observations. A PSF top-hat profile helps to minimize the errors contribution due to the uncertainty on the knowledge of the detector flat field. This work has been carried out during the recent design study in the framework of the ESA small mission CHEOPS. Because of lack of perfect flat-fielding information, in the CHEOPS optics it is required to spread the light of a source into a well defined angular area, in a manner as uniform as possible. Furthermore this should be accomplished still retaining the features of a true focal plane onto the detector. In this way, for instance, the angular displacement on the focal plane is fully retained and in case of several stars in a field these look as separated as their distance is larger than the spreading size. An obvious way is to apply a defocus, while the presence of an intermediate pupil plane in the Back End Optics makes attractive to introduce here an optical device that is able to spread the light in a well defined manner, still retaining the direction of the chief ray hitting it. This can be accomplished through an holographic diffuser or through a lenslet array. Both techniques implement the concept of segmenting the pupil into several sub-zones where light is spread to a well defined angle. We present experimental results on how to deliver such PSF profile by mean of holographic diffuser and lenslet array. Both the devices are located in an intermediate pupil plane of a properly scaled laboratory setup mimicking the CHEOPS optical design configuration. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Performing experiments with transactinide elements demands highly sensitive detection methods due to the extremely low production rates (one-atom-at-a-time conditions). Preseparation with a physical recoil separator is a powerful method to significantly reduce the background in experiments with sufficiently long-lived isotopes (t1/2≥0.5 s). In the last years, the new gas-filled TransActinide Separator and Chemistry Apparatus (TASCA) was installed and successfully commissioned at GSI. Here, we report on the design and performance of a Recoil Transfer Chamber (RTC) for TASCA—an interface to connect various chemistry and counting setups with the separator. Nuclear reaction products recoiling out of the target are separated according to their magnetic rigidity within TASCA, and the wanted products are guided to the focal plane of TASCA. In the focal plane, they pass a thin Mylar window that separates the ∼1 mbar atmosphere in TASCA from the RTC kept at ∼1 bar. The ions are stopped in the RTC and transported by a continuous gas flow from the RTC to the ancillary setup. In this paper, we report on measurements of the transportation yields under various conditions and on the first chemistry experiments at TASCA—an electrochemistry experiment with osmium and an ion exchange experiment with the transactinide element rutherfordium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we report on an optical tolerance analysis of the submillimeter atmospheric multi-beam limb sounder, STEAMR. Physical optics and ray-tracing methods were used to quantify and separate errors in beam pointing and distortion due to reflector misalignment and primary reflector surface deformations. Simulations were performed concurrently with the manufacturing of a multi-beam demonstrator of the relay optical system which shapes and images the beams to their corresponding receiver feed horns. Results from Monte Carlo simulations show that the inserts used for reflector mounting should be positioned with an overall accuracy better than 100 μm (~ 1/10 wavelength). Analyses of primary reflector surface deformations show that a deviation of magnitude 100 μm can be tolerable before deployment, whereas the corresponding variations should be less than 30 μm during operation. The most sensitive optical elements in terms of misalignments are found near the focal plane. This localized sensitivity is attributed to the off-axis nature of the beams at this location. Post-assembly mechanical measurements of the reflectors in the demonstrator show that alignment better than 50 μm could be obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The CHaracterising ExOPlanet Satellite (CHEOPS) is a joint ESA-Switzerland space mission (expected to launch in 2017) dedicated to search for exoplanet transits by means of ultra-high precision photometry. CHEOPS will provide accurate radii for planets down to Earth size. Targets will mainly come from radial velocity surveys. The CHEOPS instrument is an optical space telescope of 30 cm clear aperture with a single focal plane CCD detector. The tube assembly is passively cooled and thermally controlled to support high precision, low noise photometry. The telescope feeds a re-imaging optic, which supports the straylight suppression concept to achieve the required Signal to Noise. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Real cameras have a limited depth of field. The resulting defocus blur is a valuable cue for estimating the depth structure of a scene. Using coded apertures, depth can be estimated from a single frame. For optical flow estimation between frames, however, the depth dependent degradation can introduce errors. These errors are most prominent when objects move relative to the focal plane of the camera. We incorporate coded aperture defocus blur into optical flow estimation and allow for piecewise smooth 3D motion of objects. With coded aperture flow, we can establish dense correspondences between pixels in succeeding coded aperture frames. We compare several approaches to compute accurate correspondences for coded aperture images showing objects with arbitrary 3D motion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue just as is common in echo ultrasound. We demonstrate in three-dimensional simulations, phantom experiments, and in vivo mouse experiments that for vascular imaging this interpretation is often inaccurate. The cylindrical blood vessels emit anisotropic acoustic transients, which can be sensitively detected only if the direction of acoustic radiation coincides with the probe aperture. Our results reveal for this reason that the signal amplitude of different blood vessels may differ even if the vessels have the same diameter and initial pressure distribution but different orientation relative to the imaging plane. This has important implications for the image interpretation, for the probe guidance technique, and especially in cases when a quantitative reconstruction of the optical tissue properties is required.