Herein is presented a technique for minimally invasive sentinel node mapping. The patient had apparently early stage endometrial cancer. Sentinel node mapping was performed using a hysteroscopic injection of indocyanine green followed by laparoscopic sentinel node detection via near-infrared fluorescence. This technique ensures delineation of lymphatic drainage from the tumor area, thus achieving accurate detection of sentinel nodes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ABSTRACT Varying pulmonary shunt fractions during the respiratory cycle cause oxygen oscillations during mechanical ventilation. In artificially damaged lungs, cyclical recruitment of atelectasis is responsible for varying shunt according to published evidence. We introduce a complimentary hypothesis that cyclically varying shunt in healthy lungs is caused by cyclical redistribution of pulmonary perfusion. Administration of crystalloid or colloid infusions would decrease oxygen oscillations if our hypothesis was right. Therefore, n = 14 mechanically ventilated healthy pigs were investigated in 2 groups: crystalloid (fluid) versus no-fluid administration. Additional volume interventions (colloid infusion, blood withdrawal) were carried out in each pig. Intra-aortal PaO(2) oscillations were recorded using fluorescence quenching technique. Phase shift of oxygen oscillations during altered inspiratory to expiratory (I:E) ventilation ratio and electrical impedance tomography (EIT) served as control methods to exclude that recruitment of atelectasis is responsible for oxygen oscillations. In hypovolemia relevant oxygen oscillations could be recorded. Fluid and volume state changed PaO(2) oscillations according to our hypothesis. Fluid administration led to a mean decline of 105.3 mmHg of the PaO(2) oscillations amplitude (P < 0.001). The difference of the amplitudes between colloid administration and blood withdrawal was 62.4 mmHg in pigs not having received fluids (P = 0.0059). Fluid and volume state also changed the oscillation phase during altered I:E ratio. EIT excluded changes of regional ventilation (i.e., recruitment of atelectasis) to be responsible for these oscillations. In healthy pigs, cyclical redistribution of pulmonary perfusion can explain the size of respiratory-dependent PaO(2) oscillations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a case of laparoscopic surgical management of an iatrogenic lymphorrhea using indocyanine green (ICG). A case of a patient who developed recurrent symptomatic lymphorrhea after laparoscopic radical hysterectomy and bilateral pelvic lymphadenectomy for an early stage cervical cancer is presented. Intraoperative bipedal interdigital subcutaneous injection of ICG exactly localized the disrupted lymphatic duct on fluorescence imaging performed with a near-infrared laparoscopic fluorescent optic device, thus allowing a successful surgical repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The time-course of dark adaptation provides valuable insights into the function and interactions between the rod and cone pathways in the retina. Here we describe a technique that uses the flash electroretinogram (ERG) response to probe the functional integrity of the cone and rod pathways during the dynamic process of dark adaptation in the mouse. Retinal sensitivity was estimated from the stimulus intensity required to maintain a 30 microV criterion b-wave response during a 40 min period of dark adaptation. When tracked in this manner, dark adaptation functions in WT mice depended upon the bleaching effects of initial background adaptation conditions. Altered dark adaptation functions, commensurate with the functional deficit were recorded in pigmented mice that lacked cone function (Gnat2 ( cplf3 )) and in WT mice injected with a toxin, sodium iodate (NaIO(3)), which targets the retinal pigment epithelium and also has downstream effects on photoreceptors. These data demonstrate that this adaptive tracking procedure measures retinal sensitivity and the contributions of the rod and/or cone pathways during dark adaptation in both WT control and mutant mice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Fundus autofluorescence (FAF) cannot only be characterized by the intensity or the emission spectrum, but also by its lifetime. As the lifetime of a fluorescent molecule is sensitive to its local microenvironment, this technique may provide more information than fundus autofluorescence imaging. We report here the characteristics and repeatability of FAF lifetime measurements of the human macula using a new fluorescence lifetime imaging ophthalmoscope (FLIO). METHODS A total of 31 healthy phakic subjects were included in this study with an age range from 22 to 61 years. For image acquisition, a fluorescence lifetime ophthalmoscope based on a Heidelberg Engineering Spectralis system was used. Fluorescence lifetime maps of the retina were recorded in a short- (498-560 nm) and a long- (560-720 nm) spectral channel. For quantification of fluorescence lifetimes a standard ETDRS grid was used. RESULTS Mean fluorescence lifetimes were shortest in the fovea, with 208 picoseconds for the short-spectral channel and 239 picoseconds for the long-spectral channel, respectively. Fluorescence lifetimes increased from the central area to the outer ring of the ETDRS grid. The test-retest reliability of FLIO was very high for all ETDRS areas (Spearman's ρ = 0.80 for the short- and 0.97 for the long-spectral channel, P < 0.0001). Fluorescence lifetimes increased with age. CONCLUSIONS The FLIO allows reproducible measurements of fluorescence lifetimes of the macula in healthy subjects. By using a custom-built software, we were able to quantify fluorescence lifetimes within the ETDRS grid. Establishing a clinically accessible standard against which to measure FAF lifetimes within the retina is a prerequisite for future studies in retinal disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

​2-Aminopurine (​2AP) is a fluorescent isomer of ​adenine and has a fluorescence lifetime of ~11 ns in water. It is widely used in biochemical settings as a site-specific fluorescent probe of DNA and RNA structure and base-flipping and -folding. These assays assume that ​2AP is intrinsically strongly fluorescent. Here, we show this not to be the case, observing that gas-phase, jet-cooled ​2-aminopurine and ​9-methyl-2-aminopurine have very short fluorescence lifetimes (156 ps and 210 ps, respectively); they are, to all intents and purposes, non-fluorescent. We find that the lifetime of ​2-aminopurine increases dramatically when it is part of a hydrate cluster, 2AP·(H2O)n, where n = 1–3. Not only does it depend on the presence of water molecules, it also depends on the specific hydrogen-bonding site to which they attach and on the number of H2O molecules at that site. We selectively microhydrate ​2-aminopurine at its sugar-edge, cis-amino or trans-amino sites and see that its fluorescence lifetime increases by 4, 50 and 95 times (to 14.5 ns), respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Fluorescence lifetime imaging ophthalmoscopy is a technique to measure decay times of endogenous retinal fluorophores. The purpose of this study was to investigate fluorescence lifetimes in eyes with central and branch retinal artery occlusion. METHODS Twenty-four patients with central or branch retinal artery occlusion were included in this study. The contralateral unaffected fellow eye was used as control. Measurements were performed using a fluorescence lifetime imaging ophthalmoscope based on a HRA Spectralis system. Fluorescence excitation wavelength was 473 nm, and mean lifetimes were measured in a short (498-560 nm) and in a long (560-720 nm) spectral channel. Fluorescence lifetimes in the area of retinal artery occlusion were measured and compared to corresponding areas in contralateral unaffected eyes. Additionally, findings were correlated to optical coherence tomography measurements. RESULTS Retinal lifetime images of 24 patients with retinal artery occlusion were analyzed. Mean retinal fluorescence lifetimes were prolonged by 50% in the short and 20% in the long spectral channel in ischemic retinal areas up to 3 days after retinal artery occlusion compared to the contralateral unaffected eyes. In the postacute disease stage there was no difference between the lifetimes of affected areas and unaffected fellow eyes. CONCLUSIONS Retinal artery occlusion leads to significantly longer fluorescence lifetimes of the retina in the acute phase and may serve as a useful indicator for acute ischemic retinal damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE (99)TC combined with blue-dye mapping is considered the best sentinel lymph node (SLN) mapping technique in cervical cancer. Indocyanine green (ICG) with near infrared fluorescence imaging has been introduced as a new methodology for SLN mapping. The aim of this study was to compare these two techniques in the laparoscopic treatment of cervical cancer. METHODS Medical records of patients undergoing laparoscopic SLN mapping for cervical cancer with either (99)Tc and patent blue dye (Group 1) or ICG (Group 2) from April 2008 until August 2012 were reviewed. Sensitivity, specificity, and overall and bilateral detection rates were calculated and compared. RESULTS Fifty-eight patients were included in the study-36 patients in Group 1 and 22 patients in Group 2. Median tumor diameter was 25 and 29 mm, and mean SLN count was 2.1 and 3.7, for Groups 1 and 2, respectively. Mean non-SLN (NSLN) count was 39 for both groups. SLNs were ninefold more likely to be affected by metastatic disease compared with NSLNs (p < 0.005). Sensitivity and specificity were both 100 %. Overall detection rates were 83 and 95.5 % (p = nonsignificant), and bilateral detection rates were 61 and 95.5 % (p < 0.005), for Groups 1 and 2, respectively. In 75 % of cases, SLNs were located along the external or internal iliac nodal basins. CONCLUSIONS ICG SLN mapping in cervical cancer provides high overall and bilateral detection rates that compare favorably with the current standard of care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sentinel lymph node (SLN) detection techniques have the potential to change the standard of surgical care for patients with prostate cancer. We performed a lymphatic mapping study and determined the value of fluorescence SLN detection with indocyanine green (ICG) for the detection of lymph node metastases in intermediate- and high-risk patients undergoing radical prostatectomy and extended pelvic lymph node dissection. A total of 42 patients received systematic or specific ICG injections into the prostate base, the midportion, the apex, the left lobe, or the right lobe. We found (1) that external and internal iliac regions encompass the majority of SLNs, (2) that common iliac regions contain up to 22% of all SLNs, (3) that a prostatic lobe can drain into the contralateral group of pelvic lymph nodes, and (4) that the fossa of Marcille also receives significant drainage. Among the 12 patients who received systematic ICG injections, 5 (42%) had a total of 29 lymph node metastases. Of these, 16 nodes were ICG positive, yielding 55% sensitivity. The complex drainage pattern of the prostate and the low sensitivity of ICG for the detection of lymph node metastases reported in our study highlight the difficulties related to the implementation of SNL techniques in prostate cancer. PATIENT SUMMARY There is controversy about how extensive lymph node dissection (LND) should be during prostatectomy. We investigated the lymphatic drainage of the prostate and whether sentinel node fluorescence techniques would be useful to detect node metastases. We found that the drainage pattern is complex and that the sentinel node technique is not able to replace extended pelvic LND.