8 resultados para fluid characterization

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the ranges of Hounsfield unit (HU) found in body fluids, putrefaction fluids, and blood on postmortem CT and how these ranges are affected by postmortem interval, temperatures, and CT beam energy. Body fluids, putrefaction fluids, and blood from a total of 53 corpses were analyzed to determine the ranges of HU values from postmortem CT images that were taken prior to autopsy. The fluids measured in CT images were obtained at autopsy and examined in terms of macroscopic and microscopic appearances. Body fluids and blood were also collected in plastic bottles, which were subjected to CT scans at different beam energies (80-130 kV) and at various fluid temperatures (4 to 40 °C). At a postmortem interval of 1 to 4 days, the ranges of HU values of the serous fluids (13-38 HU) and the nonsedimented blood (40-88 HU) did not overlap. In the sedimented blood, the upper serum layer exhibited HU value ranges that overlapped with those of the serous fluids. The putrefaction fluids exhibited a range of HU values between 80 and -130 HU. Elevated HU values were observed in fluids with accretive cell impurities. HU values decreased slightly with increasing temperature and CT beam energy. We concluded that serous fluids and blood in fresh corpses can be characterized and differentiated from each other based on HU value ranges. In contrast, body fluids in decomposed corpses cannot be differentiated by their HU value ranges. Different beam energies and corpse temperatures had only minor influences on HU value ranges and therefore should not be obstacles to the differentiation and characterization of body fluids and blood.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An implantable transducer for monitoring the flow of Cerebrospinal fluid (CSF) for the treatment of hydrocephalus has been developed which is based on measuring the heat dissipation of a local thermal source. The transducer uses passive telemetry at 13.56 MHz for power supply and read out of the measured flow rate. The in vitro performance of the transducer has been characterized using artificial Cerebrospinal Fluid (CSF) with increased protein concentration and artificial CSF with 10\% fresh blood. After fresh blood was added to the artificial CSF a reduction of flow rate has been observed in case that the sensitive surface of the flow sensor is close to the sedimented erythrocytes. An increase of flow rate has been observed in case that the sensitive surface is in contact with the remaining plasma/artificial CSF mix above the sediment which can be explained by an asymmetric flow profile caused by the sedimentation of erythrocythes having increased viscosity compared to artificial CSF. After removal of blood from artificial CSF, no drift could be observed in the transducer measurement which could be associated to a deposition of proteins at the sensitive surface walls of the packaged flow transducer. The flow sensor specification requirement of +-10\% for a flow range between 2 ml/h and 40 ml/h. could be confirmed at test conditions of 37 degrees C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Insect bite hypersensitivity (IBH) is an IgE-mediated seasonal dermatitis of the horses associated with bites of Simulium (black fly) and Culicoides (midge) species. Although cross-reactivity between Simulium and Culicoides salivary gland extracts has been demonstrated, the molecular nature of the allergens responsible for the observed cross-reactivity remains to be elucidated. In this report we demonstrate for the first time in veterinary medicine that a homologous allergen, present in the salivary glands of both insects, shows extended IgE cross-reactivity in vitro and in vivo. The cDNA sequences coding for both antigen 5 like allergens termed Sim v 1 and Cul n 1 were amplified by PCR, subcloned in high level expression vectors, and produced as [His](6)-tagged proteins in Escherichia coli. The highly pure recombinant proteins were used to investigate the prevalence of sensitization in IBH-affected horses by ELISA and their cross-reactive nature by Western blot analyses, inhibition ELISA and intradermal skin tests (IDT). The prevalence of sensitization to Sim v 1 and Cul n 1 among 48 IBH-affected horses was 37% and 35%, respectively. In contrast, serum IgE levels to both allergens in 24 unaffected horses did not show any value above background. Both proteins strongly bound serum IgE from IBH-affected horses in Western blot analyses, demonstrating the allergenic nature of the recombinant proteins. Extended inhibition ELISA experiments clearly showed that Sim v 1 in fluid phase is able to strongly inhibit binding of serum IgE to solid phase coated Cul n 1 in a concentration dependent manner and vice versa. This crucial experiment shows that the allergens share common IgE-binding epitopes. IDT with Sim v 1 and Cul n 1 showed clear immediate and late phase reactions to the allergen challenges IBH-affected horses, whereas unaffected control horses do not develop relevant immediate hypersensitivity reactions. In some horses, however, mild late phase reactions were observed 4h post-challenge, a phenomenon reported to occur also in challenge experiments with Simulium and Culicoides crude extracts probably related to lipopolysaccaride contaminations which are also present in E. coli-expressed recombinant proteins. In conclusion our data demonstrate that IgE-mediated cross-reactivity to homologous allergens, a well-known clinically relevant phenomenon in human allergy, also occurs in veterinary allergy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drip loss is the loss of fluid from a piece of meat without mechanical force and represents an important meat quality trait. Previous work revealed a quantitative trait locus (QTL) for drip loss in pork in an experimental Duroc x Pietrain (DUPI) F2 family on SSC 5. Based on functional data indicating their possible involvement in water holding capacity and their expression in skeletal muscle, we selected five positional candidates (ACO2, ADSL, CBY1, KCNJ4, PLA2AG6) out of 130 predicted genes in the QTL interval for further analysis. We performed a mutation analysis of all coding exons and discovered 204 polymorphisms. We genotyped 39 single nucleotide polymorphisms (SNPs) in 192 Pietrain pigs with extreme drip loss phenotypes and detected a possible association with drip loss for one non-coding SNP in the ADSL gene (ss107793818, p(raw) = 0.021). Correspondingly, ADSL diplotypes were associated with drip loss and pH1 of M. longissimus dorsi. However, after correction for multiple testing, none of the tested SNPs were significantly associated with drip loss. One possible explanation for these results is that one of the QTL-alleles from the experimental DUPI family may be fixed or nearly fixed in the tested Pietrain population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A multimodal MR study including relaxometry, diffusion tensor imaging (DTI), and MR spectroscopy was performed on patients with classical phenylketonuria (PKU) and matched controls, to improve our understanding of white matter (WM) lesions. Relaxometry yields information on myelin loss or malformation and may substantiate results from DTI attributed to myelin changes. Relaxometry was used to determine four brain compartments in normal-appearing brain tissue (NABT) and in lesions: water in myelin bilayers (myelin water, MW), water in gray matter (GM), water in WM, and water with long relaxation times (cerebrospinal fluid [CSF]-like signals). DTI yielded apparent diffusion coefficients (ADCs) and fractional anisotropies. MW and WM content were reduced in NABT and in lesions of PKU patients, while CSF-like signals were significantly increased. ADC values were reduced in PKU lesions, but also in the corpus callosum. Diffusion anisotropy was reduced in lesions because of a stronger decrease in the longitudinal than in the transverse diffusion. WM content and CSF-like components in lesions correlated with anisotropy and ADC. ADC values in lesions and in the corpus callosum correlated negatively with blood and brain phenylalanine (Phe) concentrations. Intramyelinic edema combined with vacuolization is a likely cause of the WM alterations. Correlations between diffusivity and Phe concentrations confirm vulnerability of WM to high Phe concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A polypeptide (Em2a) purified by affinity chromatography from the Echinococcus multilocularis metacestode showed a high degree of purity as assayed by SDS-PAGE and analytical isoelectrical focusing. A minor contamination with host albumin was revealed. Estimation of relative mol. mass gave a value of 54,000. The isoelectric point was found to be 4.8. Antigenic activity of the polypeptide was demonstrated by immunoprecipitation and western blotting. In these assays the protein was recognized only by homologous sera from patients infected with larval E. multilocularis. This antigen (Em2a) did not react in the ELISA with sera from patients infected with heterologous helminths; these sera were highly cross-reacting with antigen from E. granulosus hydatid fluid. Seventy-three (94%) from 78 investigated patients (alveolar echinococcosis) showed a seropositive reaction with the polypeptide Em2a.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Deep geological storage of radioactive waste foresees cementitious materials as reinforcement of tunnels and as backfill. Bentonite is proposed to enclose spent fuel canisters and as drift seals. Sand/bentonite (s/b) is foreseen as backfill material of access galleries or as drift seals. The emplacement of cementitious material next to clay material generates an enormous chemical gradient in pore-water composition that drives diffusive solute transport. Laboratory studies and reactive transport modeling predicted significant mineral alteration at and near interfaces, mainly resulting in a decrease of porosity in bentonite. The goal of this thesis was to characterize and quantify the cement/bentonite interactions both spatially and temporally in laboratory experiments. A newly developed mobile X-ray transparent core infiltration device was used to perform X-ray computed tomography (CT) scans without interruption of running experiments. CT scans allowed tracking the evolution of the reaction plume and changes in core volume/diameter/density during the experiments. In total 4 core infiltration experiments were carried out for this study with the compacted and saturated cores consisting of MX-80 bentonite and sand/MX-80 bentonite mixture (s/b; 65/35%). Two different high-pH cementitious pore-fluids were infiltrated: a young (early) ordinary Portland cement pore-fluid (APWOPC; K+–Na+–OH-; pH 13.4; ionic strength 0.28 mol/kg) and a young ‘low-pH’ ESDRED shotcrete pore-fluid (APWESDRED; Ca2+–Na+–K+–formate; pH 11.4; ionic strength 0.11 mol/kg). The experiments lasted between 1 and 2 years. In both bentonite experiments, the hydraulic conductivity was strongly reduced after switching to high-pH fluids, changing eventually from an advective to a diffusion-dominated transport regime. The reduction was mainly induced by mineral precipitation and possibly partly also by high ionic strength pore-fluids. Both bentonite cores showed a volume reduction and a resulting transient flow in which pore-water was squeezed out during high-pH infiltration. The outflow chemistry was characterized by a high ionic strength, while chloride in the initial pore water got replaced as main anionic charge carrier by sulfate, originating from gypsum dissolution. The chemistry of the high-pH fluids got strongly buffered by the bentonite, consuming hydroxide and in case of APWESDRED also formate. Hydroxide got consumed by mineral reactions (saponite and possibly talc and brucite precipitation), while formate being affected by bacterial degradation. Post-mortem analysis showed reaction zones near the inlet of the bentonite core, characterized by calcium and magnesium enrichment, consisting predominately of calcite and saponite, respectively. Silica got enriched in the outflow, indicating dissolution of silicate-minerals, identified as preferentially cristobalite. In s/b, infiltration of APWOPC reduced the hydraulic conductivity strongly, while APWESDRED infiltration had no effect. The reduction was mainly induced by mineral precipitation and probably partly also by high ionic strength pore-fluids. Not clear is why the observed mineral precipitates in the APWESDRED experiment had no effect on the fluid flow. Both s/b cores showed a volume expansion along with decreasing ionic strengths of the outflow, due to mineral reactions or in case of APWESDRED infiltration also mediated by microbiological activity, consuming hydroxide and formate, respectively. The chemistry of the high-pH fluids got strongly buffered by the s/b. In the case of APWESDRED infiltration, formate reached the outflow only for a short time, followed by enrichment in acetate, indicating most likely biological activity. This was in agreement to post-mortem analysis of the core, observing black spots on the inflow surface, while the sample had a rotten-egg smell indicative of some sulfate reduction. Post-mortem analysis showed further in both cores a Ca-enrichment in the first 10 mm of the core due to calcite precipitation. Mg-enrichment was only observed in the APWOPC experiment, originating from newly formed saponite. Silica got enriched in the outflow of both experiments, indicating dissolution of silicate-minerals, identified in the OPC experiment as cristobalite. The experiments attested an effective buffering capacity for bentonite and s/b, a progressing coupled hydraulic-chemical sealing process and also the preservation of the physical integrity of the interface region in this setup with a total pressure boundary condition on the core sample. No complete pore-clogging was observed but the hydraulic conductivity got rather strongly reduced in 3 experiments, explained by clogging of the intergranular porosity (macroporosity). Such a drop in hydraulic conductivity may impact the saturation time of the buffer in a nuclear waste repository, although the processes and geometry will be more complex in repository situation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to investigate whether serous fluids, blood, cerebrospinal fluid (CSF), and putrefied CSF can be characterized and differentiated in synthetically calculated magnetic resonance (MR) images based on their quantitative T 1, T 2, and proton density (PD) values. Images from 55 postmortem short axis cardiac and 31 axial brain 1.5-T MR examinations were quantified using a quantification sequence. Serous fluids, fluid blood, sedimented blood, blood clots, CSF, and putrefied CSF were analyzed for their mean T 1, T 2, and PD values. Body core temperature was measured during the MRI scans. The fluid-specific quantitative values were related to the body core temperature. Equations to correct for temperature differences were generated. In a 3D plot as well as in statistical analysis, the quantitative T 1, T 2 and PD values of serous fluids, fluid blood, sedimented blood, blood clots, CSF, and putrefied CSF could be well differentiated from each other. The quantitative T 1 and T 2 values were temperature-dependent. Correction of quantitative values to a temperature of 37 °C resulted in significantly better discrimination between all investigated fluid mediums. We conclude that postmortem 1.5-T MR quantification is feasible to discriminate between blood, serous fluids, CSF, and putrefied CSF. This finding provides a basis for the computer-aided diagnosis and detection of fluids and hemorrhages.