31 resultados para flat foot

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Navigation through a previously deployed and deformed stent is a difficult interventional task. Inadvertent navigation through the struts of a stent can potentially lead to incomplete secondary stent extension and vessel occlusion. Better visualisation of the pathway through the stent can reduce the risks of the procedural complications and reduce the reluctance of the interventionalist to navigate through a previously deployed stent. We describe a technique of visualisation of the pathway navigated by a guidewire through a previously deployed deformed and fractured carotid stent by the use of DynaCT. Three-dimensional reconstruction of the stent/microwire allows excellent visualisation of the correct pathway of the microwire within the stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CBV is a vital perfusion parameter in estimating the viability of brain parenchyma (eg, in cases of ischemic stroke or after interventional vessel occlusion). Recent technologic advances allow parenchymal CBV imaging tableside in the angiography suite just before, during, or after an interventional procedure. The aim of this work was to analyze our preliminary clinical experience with this new imaging tool in different neurovascular interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ulcerated diabetic foot is a complex problem. Ischaemia, neuropathy and infection are the three pathological components that lead to diabetic foot complications, and they frequently occur together as an aetiologic triad. Neuropathy and ischaemia are the initiating factors, most often together as neuroischaemia, whereas infection is mostly a consequence. The role of peripheral arterial disease in diabetic foot has long been underestimated as typical ischaemic symptoms are less frequent in diabetics with ischaemia than in non-diabetics. Furthermore, the healing of a neuroischaemic ulcer is hampered by microvascular dysfunction. Therefore, the threshold for revascularising neuroischaemic ulcers should be lower than that for purely ischaemic ulcers. Previous guidelines have largely ignored these specific demands related to ulcerated neuroischaemic diabetic feet. Any diabetic foot ulcer should always be considered to have vascular impairment unless otherwise proven. Early referral, non-invasive vascular testing, imaging and intervention are crucial to improve diabetic foot ulcer healing and to prevent amputation. Timing is essential, as the window of opportunity to heal the ulcer and save the leg is easily missed. This chapter underlines the paucity of data on the best way to diagnose and treat these diabetic patients. Most of the studies dealing with neuroischaemic diabetic feet are not comparable in terms of patient populations, interventions or outcome. Therefore, there is an urgent need for a paradigm shift in diabetic foot care; that is, a new approach and classification of diabetics with vascular impairment in regard to clinical practice and research. A multidisciplinary approach needs to implemented systematically with a vascular surgeon as an integrated member. New strategies must be developed and implemented for diabetic foot patients with vascular impairment, to improve healing, to speed up healing rate and to avoid amputation, irrespective of the intervention technology chosen. Focused studies on the value of predictive tests, new treatment modalities as well as selective and targeted strategies are needed. As specific data on ulcerated neuroischaemic diabetic feet are scarce, recommendations are often of low grade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent publications have renewed the debate regarding the number of foot compartments. There is also no consensus regarding allocation of individual muscles and communication between compartments. The current study examines the anatomic topography of the foot compartments anew using 32 injections of epoxy-resin and subsequent sheet plastination in 12 cadaveric foot specimens. Six compartments were identified: dorsal, medial, lateral, superficial central, deep forefoot, and deep hindfoot compartments. Communication was evident between the deep hindfoot compartment and the superficial central and deep central forefoot compartments. In the hindfoot, the neurovascular bundles were located in separate tissue sheaths between the central hindfoot compartment and the medial compartment. In the forefoot, the medial and lateral bundles entered the deep central forefoot compartment. The deep central hindfoot compartment housed the quadratus plantae muscle, and after calcaneus fracture could develop an isolated compartment syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p = 0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a father and daughter with hand-foot-genital syndrome (HFGS) with typical skeletal and genitourinary anomalies due to a 14-residue polyalanine expansion in HOXA13. This is the largest (32 residues) polyalanine tract so far described for any polyalanine mutant protein. Polyalanine expansion results in protein misfolding, cytoplasmic aggregation and degradation; however, HOXA13 polyalanine expansions appear to act as loss of function mutations in contrast to gain of function for HOXD13 polyalanine expansions. To address this paradox we examined the cellular consequences of polyalanine expansions on HOXA13 protein using COS cell transfection and immunocytochemistry. HOXA13 polyalanine expansion proteins form cytoplasmic aggregates, and distribution between cytoplasmic aggregates or the nucleus is polyalanine tract size-dependent. Geldanamycin, an Hsp90 inhibitor, reduces the steady-state abundance of all polyalanine-expanded proteins in transfected cells. We also found that wild-type HOXA13 or HOXD13 proteins are sequestered in HOXA13 polyalanine expansion cytoplasmic aggregates. Thus, the difference between HOXA13 polyalanine expansion loss-of-function and HOXD13 polyalanine expansion dominant-negative effect is not the ability to aggregate wild-type group 13 paralogs but perhaps to variation in activities associated with refolding, aggregation or degradation of the proteins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differential muscle weakness can cause a cavus foot deformity. Presenting complaints in the hindfoot may include ankle instability, secondary arthritis, or peroneal tendonitis. Presenting complaints in the forefoot may include stress fractures, callus formation over the lateral border of the foot, claw toes, first ray overload, and metatarsalgia. More general presenting complaints can include a drop-foot gait, decreased walking tolerance, and difficulty with shoe or orthotic fitting. To surgically correct the foot shape, soft tissue contractures need to be released, bone deformity corrected, and muscles balanced to optimize their strength and prevent recurrence of the deformity. This article reviews the diagnosis and management of the cavovarus foot secondary to longstanding muscle imbalance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flat-panel volume computed tomography (fpVCT) is a recent development in imaging. We discuss some of the musculoskeletal applications of a high-resolution flat-panel CT scanner. FpVCT has four main advantages over conventional multidetector computed tomography (MDCT): high-resolution imaging; volumetric coverage; dynamic imaging; omni-scanning. The overall effective dose of fpVCT is comparable to that of MDCT scanning. Although current fpVCT technology has higher spatial resolution, its contrast resolution is slightly lower than that of MDCT (5-10HU vs. 1-3HU respectively). We discuss the efficacy and potential utility of fpVCT in various applications related to musculoskeletal radiology and review some novel applications for pediatric bones, soft tissues, tumor perfusion, and imaging of tissue-engineered bone growth. We further discuss high-resolution CT and omni-scanning (combines fluoroscopic and tomographic imaging).