3 resultados para film mode matching

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate experimentally the transmission properties of single sub-wavelength coaxial apertures in thin metal films (t = 110 nm). Enhanced transmission through a single sub-wavelength coaxial aperture illuminated with a strongly focused radially polarized light beam is reported. In our experiments we achieved up to four times enhanced transmission through a single coaxial aperture as compared to a (hollow) circular aperture with the same outer diameter.We attribute this enhancement of transmission to the excitation of a TEM-mode for illumination with radially polarized light inside the single coaxial aperture. A strong polarization contrast is observed between the transmission for radially and azimuthally polarized illumination. Furthermore, the observed transmission through a single coaxial aperture can be strongly reduced if surface plasmons are excited. The experimental results are in good agreement with finite difference time domain (FDTD) simulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surgical navigation has proven to be a minimally invasive procedure that enables precise surgical interventions with reduced exposure to irradiation for patient and personnel. Fluoroscopy-based modules have prevailed on the market. For certain operations of the pelvis computed tomography is necessary with its high imaging quality and considerably larger scan volume. To enable navigation in these cases, matching of the CT data set and the patient's real pelvic bone is essential. The common pair point-matching algorithm is complemented by the surface-matching algorithm to achieve an even higher overall precision of the system. For conventional surface matching with a solid pointer, the bone has to be exposed from soft tissue quite extensively, using a solid pointer. This conflicts with the claim of computer-assisted surgery to be minimally invasive. We integrated an A-mode ultrasonic pointer with the intention to perform extended surface matching on the pelvic bone noninvasively. Related to the conventional method, comparable and to some extent even improved precision conditions could be established.