5 resultados para extraction efficiency

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The range of novel psychoactive substances (NPS) including phenethylamines, cathinones, piperazines, tryptamines, etc. is continuously growing. Therefore, fast and reliable screening methods for these compounds are essential and needed. The use of dried blood spots (DBS) for a fast straightforward approach helps to simplify and shorten sample preparation significantly. DBS were produced from 10 µl of whole blood and extracted offline with 500 µl methanol followed by evaporation and reconstitution in mobile phase. Reversed-phase chromatographic separation and mass spectrometric detection (RP-LC-MS/MS) was achieved within a run time of 10 min. The screening method was validated by evaluating the following parameters: limit of detection (LOD), matrix effect, selectivity and specificity, extraction efficiency, and short-term and long-term stability. Furthermore, the method was applied to authentic samples and results were compared with those obtained with a validated whole blood method used for Routine analysis of NPS. LOD was between 1 and 10 ng/ml. No interference from Matrix compounds was observed. The method was proven to be specific and selective for the analytes, although with limitations for 3-FMC/flephedrone and MDDMA/MDEA. Mean extraction efficiency was 84.6 %. All substances were stable in DBS for at least a week when cooled. Cooling was essential for the stability of cathinones. Prepared samples were stable for at least 3 days. Comparison to the validated whole blood method yielded similar results. DBS were shown to be useful in developing a rapid screening method for NPS with simplified sample preparation. Copyright © 2013 John Wiley & Sons, Ltd

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The concentration of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH) in whole blood is used as a parameter for assessing the consumption behavior of cannabis consumers. The blood level of THCCOOH-glucuronide might provide additional information about the frequency of cannabis use. To verify this assumption, a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and direct quantification of free and glucuronidated THCCOOH in human whole blood was newly developed. The method comprised protein precipitation, followed by injection of the processed sample onto a trapping column and subsequent gradient elution to an analytical column for separation and detection. The total LC run time was 4.5 min. Detection of the analytes was accomplished by electrospray ionization in positive ion mode and selected reaction monitoring using a triple-stage quadrupole mass spectrometer. The method was fully validated by evaluating the following parameters: linearity, lower limit of quantification, accuracy and imprecision, selectivity, extraction efficiency, matrix effect, carry-over, dilution integrity, analyte stability, and re-injection reproducibility. All acceptance criteria were analyzed and the predefined criteria met. Linearity ranged from 5.0 to 500 μg/L for both analytes. The method was successfully applied to whole blood samples from a large collective of cannabis consumers, demonstrating its applicability in the forensic field.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a retrospective multicentre study, the success rate and efficiency of activator treatment were analysed. All patients from two University clinics (Giessen, Germany and Berne, Switzerland) that fulfilled the selection criteria (Class II division 1 malocclusion, activator treatment, no aplasia, no extraction of permanent teeth, no syndromes, no previous orthodontic treatment except transverse maxillary expansion, full available records) were included in the study. The subject material amounted to 222 patients with a mean age of 10.6 years. Patient records, lateral head films, and dental casts were evaluated. Treatment was classified as successful if the molar relationship improved by at least half to three-fourths cusp width depending on whether or not the leeway space was used during treatment. Group comparisons were carried out using Wilcoxon two-sample and Kruskal-Wallis tests. For discrete data, chi-square analysis was used and Fisher's exact test when the sample size was small. Stepwise logistic regression was also employed. The success rate was 64 per cent in Giessen and 66 per cent in Berne. The only factor that significantly (P < 0.001) influenced treatment success was the level of co-operation. In approximately 27 per cent of the patients at both centres, the post-treatment occlusion was an 'ideal' Class I. In an additional 38 per cent of the patients, marked improvements in occlusal relationships were found. In subjects with Class II division 1 malocclusions, in which orthodontic treatment is performed by means of activators, a marked improvement of the Class II dental arch relationships can be expected in approximately 65 per cent of subjects. Activator treatment is more efficient in the late than in the early mixed dentition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the development of a new sensitive method for the analysis of alpha-dicarbonyls glyoxal (G) and methylglyoxal (MG) in environmental ice and snow is presented. Stir bar sorptive extraction with in situ derivatization and liquid desorption (SBSE-LD) was used for sample extraction, enrichment, and derivatization. Measurements were carried out using high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). As part of the method development, SBSE-LD parameters such as extraction time, derivatization reagent, desorption time and solvent, and the effect of NaCl addition on the SBSE efficiency as well as measurement parameters of HPLC-ESI-MS/MS were evaluated. Calibration was performed in the range of 1–60 ng/mL using spiked ultrapure water samples, thus incorporating the complete SBSE and derivatization process. 4-Fluorobenzaldehyde was applied as internal standard. Inter-batch precision was <12 % RSD. Recoveries were determined by means of spiked snow samples and were 78.9 ± 5.6 % for G and 82.7 ± 7.5 % for MG, respectively. Instrumental detection limits of 0.242 and 0.213 ng/mL for G and MG were achieved using the multiple reaction monitoring mode. Relative detection limits referred to a sample volume of 15 mL were 0.016 ng/mL for G and 0.014 ng/mL for MG. The optimized method was applied for the analysis of snow samples from Mount Hohenpeissenberg (close to the Meteorological Observatory Hohenpeissenberg, Germany) and samples from an ice core from Upper Grenzgletscher (Monte Rosa massif, Switzerland). Resulting concentrations were 0.085–16.3 ng/mL for G and 0.126–3.6 ng/mL for MG. Concentrations of G and MG in snow were 1–2 orders of magnitude higher than in ice core samples. The described method represents a simple, green, and sensitive analytical approach to measure G and MG in aqueous environmental samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-energy e(-) and pi(-) were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% +/- 0.5% for electrons in the beam momenta range 17.5-300 MeV/c and 6.0% +/- 1.3% for pions in the beam momenta range 172-345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter's magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution. (C) 2015 AIP Publishing LLC.