20 resultados para extracorporeal membrane oxygenation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 20-month old girl with severe pulmonary hypertension and cardiomegaly was admitted to the paediatric intensive care unit with right ventricular failure of unknown origin. Only after decompression of the heart chambers under extracorporeal membrane oxygenation (ECMO), did the pathognomonic membrane of Cor triatriatum become visible on echocardiography. The patient underwent successful surgical correction and subsequently cardiac function recovered completely. Cor triatriatum remains a rare congenital cardiac disorder with a variable presentation, often including recurrent respiratory infections before right-sided heart failure occurs. This case illustrates that ECMO can serve not only as a bridge to diagnosis, but can also facilitate correct diagnosis. Given the excellent outcome after surgical treatment, it is crucial that cardiologists rule out the possibility of cor triatriatum when assessing a child with unexplained pulmonary hypertension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In some patients with acute respiratory failure, the native lungs do not recover during extracorporeal membrane oxygenation (ECMO), or complications occur that preclude the meaningful continuation of ECMO therapy. In such cases, emergency lung transplantation (LTx) represents the only therapeutic alternative. Between May 1988 and April 1993, the authors have performed LTx after ECMO support in five of 111 lung or heart-lung transplantations (4.5%). Two patients presented with early graft failure after unilateral LTx. In these patients, ECMO was used as a bridging device to unilateral re-LTx for 1, resp. 11 days. One patient died 6 months post-operatively from chronic rejection; the other underwent a third LTx and is doing well after 42 months. In three further patients already treated with ECMO for 5 to 12 days for ARDS (n = 2) or acute respiratory failure after liver and kidney transplantation, the native lungs did not recover (n = 2) or pulmonary hemorrhage developed. The last patient (unilateral LTx) and one of the former (bilateral LTx for ARDS) are long-term survivors (12, 30 months). The remaining patient (unilateral LTx for ARDS) had severe multiorgan failure at the time of his operation and died intraoperatively. The authors conclude that ECMO no longer represents a contraindication to subsequent LTx. Their results also support the continued investigation of this combined therapeutic approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A severe adult respiratory distress syndrome after bilateral lung contusion was successfully treated by extracorporeal membrane oxygenation and subsequent double-lung transplantation in a 19-year-old man. The patient is fully rehabilitated 1 year after transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Extracorporeal membrane oxygenation (ECMO) was used to achieve temporary artificial support in cardiac and pulmonary function in 22 patients from 1987 to September 1990. Standard indications were postcardiotomy cardiogenic shock (n = 4), neonatal (n = 1) and adult respiratory distress syndrome (n = 4). ECMO was also used for extended indications, such as graft failure following heart (n = 11) or lung transplantation (n = 2). In six of these cases ECMO was instituted as a bridge device to subsequent retransplantation of either the heart (n = 4) or one lung (n = 2). One out of nine patients supported by ECMO for standard indications, and two out of 13 patients supported for extended indications are long-term survivors. This series illustrates the results with ECMO in emergency situations, in patients under immunosuppressive protocols, or in patients with advanced lung failure requiring almost complete artificial gas exchange. In such complex situations, ECMO does provide stabilization until additional therapeutic measures are in effect. ECMO cannot be recommended for postoperative cardiogenic shock but short-term ECMO support is an accepted method in most cases with graft failure or pulmonary failure or other origin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The occurrence of severe graft failure after lung transplantation which appears refractory to conventional treatment represents a difficult situation with regard to the therapeutic strategies available. Of 17 patients undergoing single lung transplantation at our center, 2 developed early graft failure. In both, temporary artificial cardiopulmonary support by means of extracorporeal membrane oxygenation became necessary as a bridge to retransplantation. Both patients were successfully retransplanted after 8 h and 232 h, respectively, of extra-corporeal support. Postoperatively, there was a variety of complications. The first patient completely recovered from temporary severe cerebral dysfunction diagnosed as "locked-in syndrome". She was discharged from hospital on the 93rd postoperative day and remains alive and well 10 months after her operation. The other patient recovered well early after retransplantation. Later, however, airway problems developed, requiring the implantation of endotracheal stents. Cachexia and several episodes of viral pneumonia contributed to the progressive deterioration of her clinical status. She finally died after being hospitalized for 5 months after the original operation. These two cases illustrate the feasibility of using extracorporeal membrane oxygenation as a bridge to pulmonary transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Extracorporeal membrane oxygenation (ECMO) offers therapeutic options in refractory respiratory and/or cardiac failure. Systemic anticoagulation with heparin is routinely administered. However, in patients with heparin-induced thrombocytopenia or heparin resistance, the direct thrombin inhibitor bivalirudin is a valid option and has been increasingly used for ECMO anticoagulation. We aimed at evaluating its safety and its optimal dosing for ECMO. METHODS Systematic web-based literature search of PubMed and EMBASE performed via National Health Service Library Evidence and manually, updated until January 30, 2016. RESULTS The search revealed 8 publications relevant to the topic (5 case reports). In total, 58 patients (24 pediatrics) were reported (18 received heparin as control groups). Bivalirudin was used with or without loading dose, followed by infusion at different ranges (lowest 0.1-0.2 mg/kg/h without loading dose; highest 0.5 mg/kg/h after loading dose). The strategies for monitoring anticoagulation and optimal targets were dissimilar (activated partial thromboplastin time 45-60 seconds to 42-88 seconds; activated clotting time 180-200 seconds to 200-220 seconds; thromboelastography in 1 study). CONCLUSION Bivalirudin loading dose was not always used; infusion range and anticoagulation targets were different. In this systematic review, we discuss the reasons for this variability. Larger studies are needed to establish the optimal approach with the use of bivalirudin for ECMO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Severe acute respiratory failure of varying etiology may require the temporary use of artificial gas exchange devices. So far, extracorporeal membrane oxygenation and extracorporeal carbon dioxide removal have been used successfully for this purpose. A totally implantable intravascular oxygenator (IVOX) recently became available. The authors have used IVOX in three patients who presented with severe respiratory failure secondary to pneumonia (n = 2) and post-traumatic adult respiratory distress syndrome (n = 1). At the time of implantation, all patients had hypoxemia (PaO2 less than 60) despite a 100% inspired oxygen concentration and forced mechanical ventilation. The duration of IVOX therapy ranged from 12 to 71 hr. All patients initially showed improvement in arterial oxygenation, allowing for moderate reduction of ventilator therapy after several hours. In one patient the pulmonary status deteriorated further, and she died from multiple organ failure despite IVOX therapy. One patient could be stabilized but died from other causes. The third patient is a long-term survivor 18 months after IVOX therapy. Gas transfer capabilities of IVOX are limited when compared to extracorporeal membrane oxygenation, and this may restrict its clinical applicability in cases of severe adult respiratory distress syndrome. However, IVOX may be used successfully in selected patients with less severe respiratory failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current guidelines for the treatment of hypothermic cardiocirculatory arrest recommend extracorporeal life support and rewarming, using cardiopulmonary bypass or extracorporeal membrane oxygenation circuits. Both have design-related shortcomings which may result in prolonged reperfusion time or insufficient oxygen delivery to vital organs. This article describes clear advantages of minimally invasive extracorporeal circulation systems during emergency extracorporeal life support in hypothermic arrest. The technique of minimally invasive extracorporeal circulation for reperfusion and rewarming is represented by the case of a 59-year-old patient in hypothermic cardiocirculatory arrest at 25.3°C core temperature, with multiple trauma. With femoro-femoral cannulation performed under sonographic and echocardiographic guidance, extracorporeal life support was initiated using a minimally invasive extracorporeal circulation system. Perfusing rhythm was restored at 28°C. During rewarming on the mobile circuit, trauma surveys were completed and the treatment initiated. Normothermic weaning was successful on the first attempt, trauma surgery was completed and the patient survived neurologically intact. For extracorporeal resuscitation from hypothermic arrest, minimally invasive extracorporeal circulation offers all the advantages of conventional cardiopulmonary bypass and extracorporeal membrane oxygenation systems without their shortcomings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Patients who require extracorporeal membrane oxygenation (ECMO) postsurgery for congenital heart disease (CHD) frequently experience severe bleeding episodes. Whereas recombinant-activated factor VII (rFVIIa) has proven efficacy in counteracting intractable hemorrhage in various scenarios, its use in patients on ECMO is limited by the increased risk for thrombotic events. METHODS: Between December 2004 and January 2006, ECMO was used in 10 pediatric patients following cardiac surgery, of whom seven were treated with rFVIIa because of intractable hemorrhage. Their medical records were reviewed with respect to variations in chest tube output and transfusion requirements, occlusion of or thrombus formation in the ECMO circuit and the occurrence of thromboembolic events. Outcome and rate of ECMO circuit occlusion were compared with historic controls. RESULTS: Three patients died, and four survived (none of the deaths was attributable to thrombus formation or bleeding). All patients were treated with aprotinin prior to and during rFVIIa therapy. Two patients developed an occlusion of the oxygenator, one after receiving co-medication with a FXIII concentrate, another after RBC transfusion in the ECMO system. In two patients, thrombus formation was observed in the ECMO system on inspection after discontinuation. Thromboembolic events were not observed. CONCLUSIONS: Recombinant-activated factor VII in a median dosage of 90 microg.kg(-1) was used in seven pediatric patients on ECMO. Rates of ECMO system occlusions and mortality did not differ from historic controls. Neither the reduction of chest tube output nor the blood product transfusion requirements did reach statistical significance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Posttraumatic adult respiratory distress syndrome (ARDS) still involves significant mortality, despite progress in management concepts. Current therapeutic strategies are briefly described, including kinetic therapy, high-frequency jet ventilation and extracorporeal membrane oxygenation. In addition, a spectacular case of the first successful lung transplantation for posttraumatic ARDS after failed ECMO (extracorporeal membrane oxygenation) support is reported. This young man with severe posttraumatic ARDS developed a potentially lethal bilateral pulmonary hemorrhage under treatment with ECMO, and on the basis of this bilateral pulmonary transplantation was considered to be indicated. The patient is alive and well 2 years after the procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 44-year-old male European with type I diabetes mellitus fell into diabetic ketoacidosis. In the emergency room, he developed an episode of asystole and respiratory failure requiring one cycle of cardiopulmonary resuscitation and extracorporeal membrane oxygenation (ECMO). Waking up 7 days later, he presented a bilateral complete loss of vision. Ophthalmological examination including funduscopy on days 1 and 10, after extubation, showed bilateral large round pupils non-reactive to light and a normal fundus. Neuroimaging studies, including MRI and MRA of the brain, were all within normal limits. A lumbar puncture and comprehensive serological testing excluded an infectious or rheumatic cause. An empirical high-dose intravenous steroid treatment administered for 5 days had no effect on his vision. His eye examination at 1.5 months follow-up showed a normal fundus except for progressive bilateral optic nerve disc pallor, which pointed towards the diagnosis of a posterior ischaemic optic neuropathy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.