2 resultados para evaluation of bus priority
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Data on antimicrobial use play a key role in the development of policies for the containment of antimicrobial resistance. On-farm data could provide a detailed overview of the antimicrobial use, but technical and methodological aspects of data collection and interpretation, as well as data quality need to be further assessed. The aims of this study were (1) to quantify antimicrobial use in the study population using different units of measurement and contrast the results obtained, (2) to evaluate data quality of farm records on antimicrobial use, and (3) to compare data quality of different recording systems. During 1 year, data on antimicrobial use were collected from 97 dairy farms. Antimicrobial consumption was quantified using: (1) the incidence density of antimicrobial treatments; (2) the weight of active substance; (3) the used daily dose and (4) the used course dose for antimicrobials for intestinal, intrauterine and systemic use; and (5) the used unit dose, for antimicrobials for intramammary use. Data quality was evaluated by describing completeness and accuracy of the recorded information, and by comparing farmers' and veterinarians' records. Relative consumption of antimicrobials depended on the unit of measurement: used doses reflected the treatment intensity better than weight of active substance. The use of antimicrobials classified as high priority was low, although under- and overdosing were frequently observed. Electronic recording systems allowed better traceability of the animals treated. Recording drug name or dosage often resulted in incomplete or inaccurate information. Veterinarians tended to record more drugs than farmers. The integration of veterinarian and farm data would improve data quality.
Resumo:
OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.