2 resultados para engineering mechanics

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5-302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The majority of people who sustain hip fractures after a fall to the side would not have been identified using current screening techniques such as areal bone mineral density. Identifying them, however, is essential so that appropriate pharmacological or lifestyle interventions can be implemented. A protocol, demonstrated on a single specimen, is introduced, comprising the following components; in vitro biofidelic drop tower testing of a proximal femur; high-speed image analysis through digital image correlation; detailed accounting of the energy present during the drop tower test; organ level finite element simulations of the drop tower test; micro level finite element simulations of critical volumes of interest in the trabecular bone. Fracture in the femoral specimen initiated in the superior part of the neck. Measured fracture load was 3760 N, compared to 4871 N predicted based on the finite element analysis. Digital image correlation showed compressive surface strains as high as 7.1% prior to fracture. Voxel level results were consistent with high-speed video data and helped identify hidden local structural weaknesses. We found using a drop tower test protocol that a femoral neck fracture can be created with a fall velocity and energy representative of a sideways fall from standing. Additionally, we found that the nested explicit finite element method used allowed us to identify local structural weaknesses associated with femur fracture initiation.