3 resultados para elektrische Antriebssysteme

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Barostim neo ™ system is a novel implantable device that activates the carotid baroreflex. It decreases the sympathetic activity and inhibits the renin system, which results in reduced blood pressure and heart rate. In patients with resistant hypertension, electrically activation of the baroreflex leads to an average decrease in systolic blood pressure of 38, 36, 40 and 53 mmHg at 1, 2, 3 and 4 years, respectively. Additionally, cardiac remodelling with reduced left ventricular mass and posterior wall thickness has been observed in long-term studies. In a limited number of patients with heart failure, baroreflex activation therapy leads to a decrease in muscle sympathetic nerve activity and to improved quality of life and functional capacities. The implantation procedure is safe and associated with risks comparable with those of other active implantable devices. Barostim neo is currently available in several European countries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Regelmässiges körperliches Training induziert strukturelle, elektrische und funktionelle Anpassungen des Herzens. Die grösste Herausforderung für den Arzt liegt darin, Veränderungen hinweisend für eine strukturelle Herzerkrankung von physiologischen, trainingsassoziierten Anpassungen im Sinne eines 'Athlete's heart' zu unterscheiden. Bei zugrundliegender Kardiopathie ist sportliche Aktivität nicht die Ursache, sondern kann ein Trigger für belastungsabhängige Tachyarrhythmien bzw. für den belastungsabhängigen plötzlichen Herztod (SCD) sein. Um Athleten mit einer kardialen Grunderkrankung und erhöhtem Risiko für einen SCD frühzeitig zu identifizieren wird in Europa ein Preparticipation Screening empfohlen, welches von der Schweizerischen Gesellschaft für Sportmedizin (SGSM) übernommen wurde. Dieses Screening umfasst neben der spezifischen Anamnese und der Herzauskultation auch ein Ruhe-Elektrokardiogramm (Ruhe-EKG). Aufgrund der hohen Anzahl falsch-positiver EKG-Befunde wurden in den letzten Jahren die Beurteilungskriterien des Athleten-EKGs wiederholt angepasst, die Sensitivität und insbesondere auch die Spezifität konnte mit den „verfeinerten Seattle Kriterien“ 2014 deutlich verbessert werden. Der frühen Repolarisation galt in den letzten Jahren ein Hauptaugenmerk: neben dem (Ausdauer-) Training besteht eine klare Assoziation zum männlichen Geschlecht, zur Ethnie, zu den Veränderungen des vegetativen Nervensystems und zu erhöhten QRS-Voltage-Kriterien.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiac pacemakers are routinely used for the treatment of bradyarrhythmias. Contemporary pacemakers are reliable and allow for a patient specific programming. However, pacemaker replacements due to battery depletion are common (~25 % of all implantation procedures) and bear the risk of complications. Batteryless pacemakers may allow overcoming this limitation. To power a batteryless pacemaker, a mechanism for intracorporeal energy harvesting is required. Such a generator may consist out of subcutaneously implanted solar cells, transforming the small amount of transcutaneously available light into electrical energy. Alternatively, intravascular turbines may harvest energy from the blood flow. Energy may also be harvested from the ventricular wall motion by a dedicated mechanical clockwork converting motion into electrical energy. All these approaches have successfully been tested in vivo. Pacemaker leads constitute another Achilles heel of contemporary pacemakers. Thus, leadless devices are desired. Miniaturized pacemaker circuits and suitable energy harvesting mechanisms (incorporated in a single device) may allow catheter-based implantation of the pacemaker in the heart. Such miniaturized battery- and leadless pacemakers would combine the advantages of both approaches and overcome major limitations of today’s systems.