26 resultados para drug utilization evaluation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND Inflammatory bowel disease can decrease the quality of life and induce work disability. We sought to (1) identify and quantify the predictors of disease-specific work disability in patients with inflammatory bowel disease and (2) assess the suitability of using cross-sectional data to predict future outcomes, using the Swiss Inflammatory Bowel Disease Cohort Study data. METHODS A total of 1187 patients were enrolled and followed up for an average of 13 months. Predictors included patient and disease characteristics and drug utilization. Potential predictors were identified through an expert panel and published literature. We estimated adjusted effect estimates with 95% confidence intervals using logistic and zero-inflated Poisson regression. RESULTS Overall, 699 (58.9%) experienced Crohn's disease and 488 (41.1%) had ulcerative colitis. Most important predictors for temporary work disability in patients with Crohn's disease included gender, disease duration, disease activity, C-reactive protein level, smoking, depressive symptoms, fistulas, extraintestinal manifestations, and the use of immunosuppressants/steroids. Temporary work disability in patients with ulcerative colitis was associated with age, disease duration, disease activity, and the use of steroids/antibiotics. In all patients, disease activity emerged as the only predictor of permanent work disability. Comparing data at enrollment versus follow-up yielded substantial differences regarding disability and predictors, with follow-up data showing greater predictor effects. CONCLUSIONS We identified predictors of work disability in patients with Crohn's disease and ulcerative colitis. Our findings can help in forecasting these disease courses and guide the choice of appropriate measures to prevent adverse outcomes. Comparing cross-sectional and longitudinal data showed that the conduction of cohort studies is inevitable for the examination of disability.
Resumo:
The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer were modified.
Resumo:
Simultaneous EEG/fMRI is an effective noninvasive tool for identifying and localizing the SOZ in patients with focal epilepsy. In this study, we evaluated different thresholding strategies in EEG/fMRI for the assessment of hemodynamic responses to IEDs in the SOZ of drug-resistant epilepsy.
Resumo:
OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.
Resumo:
Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial approximately 10-20 microm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model.
Resumo:
Epothilones are bacterial macrolides with potent microtubule-stabilizing and antiproliferative activity, which have served as successful lead structures for the discovery of several clinical candidates for cancer treatment. Overall, seven epothilone-type agents have been advanced to clinical evaluation in humans so far and one of these has been approved by the FDA in 2007 for clinical use in breast cancer patients. Notwithstanding these impressive numbers, however, the structural diversity represented by the collection of epothilone analogs that have been (or still are) investigated clinically is rather limited and their individual structures show little divergence from the original natural product leads. In contrast, we have elaborated a series of epothilone-derived macro-lactones, whose overall structural features significantly deviate from those of the natural epothilone scaffold and thus define new structural families of microtubule-stabilizing agents. Key elements of our hypermodification strategy are the change of the natural epoxide geometry from cis to trans, the incorporation of conformationally constrained side chains, the removal of the C(3)-hydroxyl group, and the replacement of C(12) with nitrogen. The latter modification leads to aza-macrolides that may be described as 'non-natural natural products'.
Resumo:
PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.
Resumo:
Objectives To compare the use of pair-wise meta-analysis methods to multiple treatment comparison (MTC) methods for evidence-based health-care evaluation to estimate the effectiveness and cost-effectiveness of alternative health-care interventions based on the available evidence. Methods Pair-wise meta-analysis and more complex evidence syntheses, incorporating an MTC component, are applied to three examples: 1) clinical effectiveness of interventions for preventing strokes in people with atrial fibrillation; 2) clinical and cost-effectiveness of using drug-eluting stents in percutaneous coronary intervention in patients with coronary artery disease; and 3) clinical and cost-effectiveness of using neuraminidase inhibitors in the treatment of influenza. We compare the two synthesis approaches with respect to the assumptions made, empirical estimates produced, and conclusions drawn. Results The difference between point estimates of effectiveness produced by the pair-wise and MTC approaches was generally unpredictable—sometimes agreeing closely whereas in other instances differing considerably. In all three examples, the MTC approach allowed the inclusion of randomized controlled trial evidence ignored in the pair-wise meta-analysis approach. This generally increased the precision of the effectiveness estimates from the MTC model. Conclusions The MTC approach to synthesis allows the evidence base on clinical effectiveness to be treated as a coherent whole, include more data, and sometimes relax the assumptions made in the pair-wise approaches. However, MTC models are necessarily more complex than those developed for pair-wise meta-analysis and thus could be seen as less transparent. Therefore, it is important that model details and the assumptions made are carefully reported alongside the results.
Resumo:
Diagnosis of drug hypersensitivity relies on history, skin tests, in vitro tests and provocation tests. In vitro tests are of great interest, due to possible reduction of drug provocation tests. In this review we focus on best investigated in vitro techniques for the diagnosis of T cell-mediated drug hypersensitivity reactions. As drug hypersensitivity relies on different pathomechanisms and as a single diagnostic test usually does not cover all possible reactions, it is advisable to combine different tests to increase the overall sensitivity. Recently, proliferation-based assays have been supplemented by a panel of novel in vitro tests including analysis of cytotoxic potential of effector cells (granzyme B, granulysin, CD107a), evaluation of cytokine secretion (IL-2, IL-5, IL-13, and IFN-γ) and up-regulation of cell surface activation markers (CD69). We discuss the latest findings and readout systems to identify causative drugs by detecting functional and phenotypic markers of drug-reacting cells, and their ability to enable a more conclusive diagnosis of drug allergy.
Resumo:
OXi4503 is a tubulin-binding vascular disrupting agent that has recently completed a Cancer Research UK-sponsored phase I trial. Preclinical studies demonstrated early drug-induced apoptosis in tumour endothelial cells at 1-3 h and secondary tumour cell necrosis between 6 and 72 h.
Resumo:
Data on antimicrobial use play a key role in the development of policies for the containment of antimicrobial resistance. On-farm data could provide a detailed overview of the antimicrobial use, but technical and methodological aspects of data collection and interpretation, as well as data quality need to be further assessed. The aims of this study were (1) to quantify antimicrobial use in the study population using different units of measurement and contrast the results obtained, (2) to evaluate data quality of farm records on antimicrobial use, and (3) to compare data quality of different recording systems. During 1 year, data on antimicrobial use were collected from 97 dairy farms. Antimicrobial consumption was quantified using: (1) the incidence density of antimicrobial treatments; (2) the weight of active substance; (3) the used daily dose and (4) the used course dose for antimicrobials for intestinal, intrauterine and systemic use; and (5) the used unit dose, for antimicrobials for intramammary use. Data quality was evaluated by describing completeness and accuracy of the recorded information, and by comparing farmers' and veterinarians' records. Relative consumption of antimicrobials depended on the unit of measurement: used doses reflected the treatment intensity better than weight of active substance. The use of antimicrobials classified as high priority was low, although under- and overdosing were frequently observed. Electronic recording systems allowed better traceability of the animals treated. Recording drug name or dosage often resulted in incomplete or inaccurate information. Veterinarians tended to record more drugs than farmers. The integration of veterinarian and farm data would improve data quality.
Resumo:
A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based on spectral data, is less error-prone than intensity-based visualization and evaluation methods, and provides quantitative information on the composition of the sample. The method is tested and validated in the context of the development of dermal drug delivery systems, introducing a quantitative uptake indicator to compare the performances of different delivery systems is introduced. A drug penetration study was performed in vitro. The results show that the method is able to detect, visualize and measure spectral information in tissue. In the penetration study, uptake efficiencies of different experiment setups could be discriminated and quantitatively described. The developed uptake indicator is a step towards a quantitative assessment and, in a more general view apart from pharmaceutical research, provides valuable information on tissue composition. It can potentially be used for clinical in vitro and in vivo applications.