2 resultados para distributed constraint satisfaction
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
PURPOSE: Family needs and expectations are often unmet in the intensive care unit (ICU), leading to dissatisfaction. This study assesses cross-cultural adaptability of an instrument evaluating family satisfaction in the ICU. MATERIALS AND METHODS: A Canadian instrument on family satisfaction was adapted for German language and central European culture and then validated for feasibility, validity, internal consistency, reliability, and sensitivity. RESULTS: Content validity of a preliminary translated version was assessed by staff, patients, and next of kin. After adaptation, content and comprehensibility were considered good. The adapted translation was then distributed to 160 family members. The return rate was 71.8%, and 94.4% of questions in returned forms were clearly answered. In comparison with a Visual Analogue Scale, construct validity was good for overall satisfaction with care (Spearman rho = 0.60) and overall satisfaction with decision making (rho = 0.65). Cronbach alpha was .95 for satisfaction with care and .87 for decision-making. Only minor differences on repeated measurements were found for interrater and intrarater reliability. There was no floor or ceiling effect. CONCLUSIONS: A cross-cultural adaptation of a questionnaire on family satisfaction in the ICU can be feasible, valid, internally consistent, reliable, and sensitive.
Resumo:
BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.